• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.59.2020.tde-07102019-123534
Document
Auteur
Nom complet
Beatriz Tomazi
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2019
Directeur
Jury
Poletti, Martin Eduardo (Président)
Cunha, Diego Merigue da
Hönnicke, Marcelo Gonçalves
Nicolucci, Patrícia
Titre en portugais
Protótipo experimental para aquisição de imagens por espalhamento de raios X
Mots-clés en portugais
Contraste e CNR
Espalhamento
Imagens por espalhamento de raios X
Resumé en portugais
Recentes pesquisas mostram que a componente espalhada por um objeto pode ser utilizada para formar imagens médicas, complementares às imagens convencionais. O objetivo geral deste trabalho é avaliar a técnica da formação de imagem por espalhamento de raios X por meio da análise do contraste e razão contraste ruído (contrast noise ratio, CNR) entre materiais, utilizando um detector de radiografia computadorizada e espectros de raios X clínicos. Os resultados analíticos mostraram significantes variações nos perfis radiais da imagem causadas pelos borramentos angular e espectral, apresentando grandes distorções de acordo com a variação do espectro incidente de raios X, mostrando uma forte dependência com a largura espectral, energia média do feixe e forma do espectro de raios X. Os resultados experimentais de contraste e CNR se mostraram superiores na maior parte ao longo do raio do detector comparado ao primário, apresentando regiões ótimas de integração
Titre en anglais
Experimental prototype for image acquisition by X-ray scattering
Mots-clés en anglais
Contrast and CNR
Scattering
X-ray scattering images
Resumé en anglais
Recent research shows that the scattered component of an object can be used to form medical images, complementary to conventional images. The general objective of this work is to evaluate the technique of X-ray scattering imaging by contrast analysis and contrast noise ratio (CNR) between materials using a computerized radiography detector and clinical X-ray spectra. . The analytical results showed significant variations in radial image profiles caused by angular and spectral blurring, showing large distortions according to the incident X-ray spectrum variation, showing a strong dependence on spectral width, average beam energy and spectrum shape. X-ray results. Experimental contrast and CNR results were superior for most of the detector radius compared to primary, showing optimal integration regions
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2020-01-14
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.