• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.59.2010.tde-04032011-155301
Document
Author
Full name
Michely Cristina da Silveira
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2010
Supervisor
Committee
Almeida, Adelaide de (President)
Andrade, Jurandyr Moreira de
Bruni, Aline Thais
Title in Portuguese
Distribuição da dose absorvida no tratamento da micose fungóide através da dosimetria Fricke Xilenol Gel
Keywords in Portuguese
Dosimetria e Dosímetro Fricke Xilenol Gel
Radioterapia
Abstract in Portuguese
A radioterapia utiliza a radiação ionizante para a destruição de células tumorais. O controle da dose absorvida de um tipo específico de radiação aplicada a um volume alvo (tumor) é feito através da dosimetria, (uso de sensores de radiação), que neste trabalho foram utilizados os dosímetros químicos Fricke e filme. Dentre os diversos tipos de câncer, indicados para tratamento, utilizando a radiação ionizante, têm-se também a neoplasia Micose Fungóide (MF), linfoma que se alastra na superfície e em profundidade na pele para o qual elétrons com alta energia são utilizados para seu tratamento, devido aos seus alcances. Neste trabalho o Fricke Xilenol Gel (FXG) foi utilizado para o planejamento do tratamento da MF, para averiguar a distribuição da dose absorvida proveniente das interações dos elétrons com os tecidos. Para tal, foram construídas cubetas especiais em acrílico (tomos) conformacionadas aos contornos do crânio e do abdômen, que uma vez preenchidas com o FXG serviram para avaliar as doses absorvidas num objeto simulador antropomórfico, o Rando Phantom. O simulador, completado com cubetas e filmes radiocrômicos, este último também conformacionado aos dois contornos de interesse, foi submetido à técnica de Stanford para irradiação do corpo total com elétrons de 6 MeV. Imagens CCD e de densidade radiográfica foram feitas e posteriormente avaliadas, através de perfis horizontais e verticais passando por seus centros. Estes a seguir foram analisados por programas computacionais: um desenvolvido no Matlab para as imagens do FXG e o outro pelo programa já conhecido, ImageJ, para as imagens do filme. Das medidas, pode-se inferir que o dosímetro FXG se presta, similarmente ao filme, para as avaliações da dose absorvida devida aos elétrons na superfície do paciente e no seu interior, devida à contaminação por raios-X.
Title in English
Absorbed dose distribution in the treatment of Mycosis Fungoides using Fricke Xylenol Gel dosimetry
Keywords in English
Dosimetry
Fricke Xilenol Gel Dosimete.
Radioterapy
Abstract in English
Radioterapy uses ionizing radiation to destroy tumor cells. The absorbed dose control in a target volume is done through dosimetry, using radiation sensors, being the Fricke and film used in this study. Among several types of cancer indicated for treatment using ionizing radiation, there is also the Mycosis Fungoides (MF), lymphom that spreads on surface and depth in the skin, for which high-energy electrons are used for its treatment. In this work the Fricke Xylenol Gel (FXG) was used for MF treatment control, to obtain the absorbed dose distribution from electrons interaction with the tissues. For this scope cuvettes were manufactured of acrylic (slices), with the same contours of the skull and abdomen anthropomorphic simulator tomos. Once filled with the FXG, these cuvettes were used to infer the absorbed dose by the anthropomorphic simulator Rando Phantom. This simulator, completed with the cuvettes and radiochromic films, this last one also with the same contours similar to skull and abdomen were submitted to the Stanford technique, for 6 MeV electrons total body irradiation. CCD and radiographic density images were acquired and evaluated by horizontal and vertical profiles through theirs centers. These profiles were analyzed through a computer programs: one developed in Matlab for FXG images and the other by an already known program, ImageJ, for film images. From the results one can infer that the FXG dosimeter presents similarity with that of film, in the evaluation of the absorbed dose distribution on surface and also inside of the patient.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
MichelySilveira.pdf (1.28 Mbytes)
Publishing Date
2011-06-20
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.