• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.59.2006.tde-01032011-162502
Documento
Autor
Nombre completo
Paulo Sérgio de Matos
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2006
Director
Tribunal
Pela, Carlos Alberto (Presidente)
Muhlen, Sergio Santos
Arnold, Francisco Jose
Carneiro, Antonio Adilton Oliveira
Iannetta, Odilon
Título en portugués
Avaliação de parâmetros ultra-sônicos utilizados na caracterização de tecidos ósseos
Palabras clave en portugués
BUA
calo ósseo.
ultra-som
velocidade do som
Resumen en portugués
A transmissão do ultra-som no organismo humano tem sido objeto de estudos a várias décadas, com a finalidade de promover diagnóstico. Recentemente tem sido usada para avaliar a densidade óssea e poder diagnosticar precocemente o aparecimento da osteoporose e prever o risco de fratura. Nesse trabalho foi desenvolvido um sistema capaz de gerar, receber e amplificar sinais ultra-sônicos para a avaliação da velocidade do som e atenuação em função da freqüência (BUA). A técnica usada foi a de transmissão do sinal ultra-sônico, com acoplamento por gel de ultra-som e por água (tanque acústico), que consiste no uso de dois transdutores, um para transmissão e outro para recepção, sendo a amostra posicionada entre eles. Devido ao alto índice de dispersão nas medidas ultra-sônicas, será buscado um material de referência, o qual deve possuir características tanto de velocidade do som e atenuação em função da freqüência, parecidas com a do osso (calcâneo), que será usado para calibração do equipamento e para o acompanhamento da medida óssea. Foram utilizados os parâmetros ultra-sônicos para avaliação da consolidação óssea (em tíbias de carneiro) em diferentes períodos e nos diversos tipos de fraturas. O sistema foi caracterizado em termos de temperatura e reprodutibilidade utilizando diferentes materiais. Medidas no calcâneo de voluntários, de velocidade e atenuação em função da freqüência, independente de associações patológicas, mostrou resultados compatíveis com os encontrados na literatura. Foram feitas diversas análises, com pequenas mudanças nas condições geométricas, de sinal e freqüência dos transdutores, para observar sua influência sobre as medidas de atenuação e velocidade. Isto com a finalidade de tentar relacionar as variações nas medidas de atenuação obtidas por diferentes autores.
Título en inglés
Assessment of Ultrasonics Parameters Utility in Customization of Bone Tissues.
Palabras clave en inglés
bone callus bone of sheep
BUA
speed of the sound
ultrasound
Resumen en inglés
Ultrasound transmission in human bodies has been studied for several decades in order to facilitate diagnosis. It has also been used to evaluate bone density and to diagnose early osteoporosis and future fracture risks. For this study, a system to generate, receive and amplify ultrasonic signs for speed of sound assessment and broad band ultrasound attenuation (BUA) was developed. Transmission of ultrasonic signals was performed by coupling using ultrasound gel and water (acoustic tank) and the sample placed between two transducers, one for transmission and the other for reception. Due to the high rate of the dispersion of ultrasonic measures, some reference material having the characteristics of the speed of sound and broad band ultrasound attenuation, similar to the heel bone that will be used for equipment calibration and follow-up of bone measure will have to be found. Ultrasonic parameters were used to evaluate bone consolidation (tibia of a sheep), in different periods and several kinds of fractures. Temperature and reproducibility using different materials were used to customize the system. Measures of volunteers's heel bone speed and broad band ultrasound attenuation showed results consistent with the ones from literature. Several analyses with little changes in geometric, signal and transducer frequency conditions were performed in order to observe their influence on attenuation and speed measures. Those steps were carried out in order to try to relate the variations in attenuation measures to those obtained by other authors.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
PauloMatos.pdf (10.79 Mbytes)
Fecha de Publicación
2011-03-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.