• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.58.2008.tde-23012009-170150
Documento
Autor
Nombre completo
Roberto de Oliveira Jabur
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2008
Director
Tribunal
Barros, Valdemar Mallet da Rocha (Presidente)
Peitl Filho, Oscar
Zardo, Maurício
Título en portugués
Avaliação clínica, histológica e histomorfométrica do reparo de defeitos ósseos criados em mandíbula de cães preenchidos com Biovidro 45S5 ou Biosilicato® após a colocação de implantes osseointegráveis
Palabras clave en portugués
biovidros
enxerto ósseo
formação óssea
implante
Resumen en portugués
O presente trabalho avaliou a formacao de tecido osseo ao redor de implantes osseointegraveis de titanio, apos realizacao de defeitos osseos, utilizando diferentes tipos de substitutos osseos. Foram utilizados 5 caes de raca indeterminada, os pre molares e molares mandibulares foram extraidos, passados 12 semanas, os caes foram submetidos a um novo procedimento cirurgico aonde foram realizadas as perfurações preconizados pelo fabricante dos implantes, o osso vestibular da mandibula foi desgastado ate que parte da perfuracao fosse exposta, os implantes entao foram colocados nas respectivas perfuracoes, ficando com 4 espiras expostas. Esses defeitos foram preenchidos aleatoriamente com Bioglass® 45S5, Biosilicato® , Osso autogeno, e sem nenhum material de preenchimento. 18 semanas depois da colocacao dos implantes os caes foram mortos e suas hemi-mandibulas contendo os implantes removidas e submetidas aos analises histologiaos e histomorfometricas, os dados obtidos foram submetidos ao teste de Kruskal-Wallis. A histologia dos 4 grupos estudados revelaram a presenca de tecido osseo maduro em contato com os implantes, porem sem ralacao direta com os vidros bioativos e osso autogeno. A porcentagem de contato osso implante, matriz ossea mineralizada ao redor da espira, e area de espelho, nao mostraram diferencas estatisticas significantes entre os 4 materiais testados. Os resultados indicam que a presenca de substitutos osseos nao interfere com a formacao ossea ao redor dos implantes nesse modelo experimental. E existe resposta tecidual muito semelhante entre o osso autogeno, Bioglass® 45S5 e Biosilicato.
Título en inglés
Bone formation on Ti implants in intra-bony defect sites filled with different bone substitutes: histomorphometric analysis in dogs
Palabras clave en inglés
bioactive glass
bone defects
bone formation
glass-ceramic
histomorphometry
titanium
Resumen en inglés
The aim of the present study was to investigate the amount of bone formation on Ti implants in sites with intra-bony defects filled with different bone substitutes. Mandibular premolars and first molars were extracted from 5 dogs, and after 12 weeks 3 implants were bilaterally placed in sites with intra-bony defects and each implantation site randomly received the following treatment: Biosilicate®, Bioglass® 45S5, aoutologous bone or no treatment. At 18 weeks after implantation, the hemi-mandibles containing the implants were removed and processed for morphological and histomorphometric analysis. Data were submitted to Kruskal-Wallis and Fishers test. The histological sections of the 4 experimental groups exhibited mature bone tissue in contact with implants, but not related with bioactive glasses or autologous bone used. The percentage of bone-implant contact, mineralized bone matrix between implant threads, and mineralized bone matrix within mirror area in the treated or non-treated sites were not statistically different among the 4 experimental groups. These results indicates that the presence of the bone substitutes evaluated here did not interfere with bone formation on Ti implants in sites with intra-bony defects. In addition, tissue response to Biosilicate® was similar to that of Bioglass® 45S5 and autologous bone.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
me_roberto_jabur.pdf (2.70 Mbytes)
Fecha de Publicación
2009-03-27
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.