• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.58.2014.tde-17072014-095638
Documento
Autor
Nombre completo
Gileade Pereira Freitas
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2014
Director
Tribunal
Rosa, Adalberto Luiz (Presidente)
Oliveira, Paulo Tambasco de
Sverzut, Alexander Tadeu
Título en portugués
Avaliação da resposta do tecido ósseo tipo IV a implantes osseointegráveis de titânio com diferentes tratamentos de superfície
Palabras clave en portugués
formação óssea
osseointegração
titânio
tratamento de superfície
Resumen en portugués
As alterações de superfície dos implantes de titânio (Ti) influenciam funções celulares e formação de tecido adjacente aos mesmos, mas é controverso se tais alterações trariam vantagens quando esses implantes fossem colocados em tecido ósseo de baixa qualidade. O objetivo deste estudo foi avaliar a resposta do tecido ósseo de baixa qualidade (tipo IV) a implantes de Ti com diferentes tratamentos de superfície. Para isso, implantes de Ti com superfície nanotexturizada (Ti-Nano), microtexturizada (Ti-Porous) e sem tratamento de superfície (Ti-Usinado) foram implantados em tíbias de coelhos. Após duas e seis semanas, o tecido ósseo formado ao redor dos implantes foi avaliado em cortes histológicos por desgaste e histomorfometricamente foram avaliados: a porcentagem de contato ossoimplante (BIC), porcentagem de área de osso mineralizado formado entre as espiras do implante (BABT), porcentagem da área de osso formada na área espelho (BAMA). Vários outros parâmetros morfométricos foram avaliados a partir de imagens e reconstruções tridimensionais obtidos por microtomografia. Ao final de seis semanas, foi avaliado o torque de remoção. Os resultados foram submetidos à análise de variância (ANOVA) com dois fatores de variação (tratamento de superfície e tempo de implantação) seguido do teste de Tukey (p≤0,05). Apesar de algumas diferenças estatisticamente significantes para alguns dos parâmetros morfométricos, tais diferenças não são biologicamente importantes para que pudessem ser atribuídas aos tratamentos de superfície. Tanto que, histologicamente não se observou diferença nos padrões de formação óssea ou tipo de osso formado que pudesse ser associado aos tratamentos de superfície e o torque de remoção também não foi afetado pelos tratamentos. Em conclusão, esses resultados mostraram que os tratamentos de superfície, embora sejam na escala micrométrica ou nanométrica, não induzem repostas do tecido ósseo tipo IV diferentes daquelas induzidas por superfícies sem tratamento.
Título en inglés
Evaluation of type IV bone tissue response to titanium implants with different surface treatments.
Palabras clave en inglés
bone formation
osseointegration
surface treatment
titanium
Resumen en inglés
Some alterations in titanium (Ti) implant surfaces influence cell functions and tissue formation in areas adjacent to the implants, but it is controversial whether these changes would bring advantages when these implants were placed in bone of poor quality. The aim of this study was to evaluate the response of poor quality bone tissue (type IV) to Ti implants with different surface treatments. For this, Ti implants with nanotextured surface (Ti-Nano), microtextured (Ti-Porous) and without surface treatment (Ti-Machined) were implanted into tibias of rabbits. After two and six weeks, the bone tissue around the implants was assessed in undecalcified histological sections and histomorphometrical analysis to evaluate: the percentage of bone-implant contact (BIC), percentage of the area of mineralized bone formed between threads (BABT), the percentage area of bone formed in the mirror area (BAMA). Several other morphometric parameters were evaluated from images and three-dimensional reconstructions obtained by microtomography. At the end of six weeks the removal torque was evaluated. The results were subjected to analysis of variance (ANOVA) with two factors of variation (surface treatment and time) followed by Tukey test (p≤0.05). Despite some statistically significant differences for some of the morphometric parameters, such differences are not biologically important and they could not be attributed to the surface treatments. In keeping with this, histological analysis failed to show any difference in bone formation that could be associated to the surface treatments and removal torque was not affected by treatments either. In conclusion, these results showed that the surface treatments, irrespective of being on the micrometer or nanometer scale, do not induce responses of type IV bone tissue different from those induced by untreated surfaces.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-04-23
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.