Disertación de Maestría
DOI
https://doi.org/10.11606/D.58.2014.tde-22042014-144350
Documento
Autor
Nombre completo
Ângelo Rafael de Vito Bordin
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2014
Director
Tribunal
Cruz Filho, Antonio Miranda da (Presidente)
Fariniuk, Luiz Fernando
Sousa Neto, Manoel Damião de
Título en portugués
Estudo do shelf life da quitosana armazenada em diferentes tipos de embalagem, por meio de colorimetria e análise da microdureza dentinária
Palabras clave en portugués
microdureza
quitosana
shelf life
Resumen en portugués
O objetivo do presente trabalho foi estudar, por meio da técnica de titulação colorimétrica e análise da microdureza dentinária, o shelf life da solução de quitosana 0,2% armazenada em frascos de vidro e plástico. Trinta caninos superiores humanos tiveram as coroas desprezadas e a porção cervical das raízes seccionada, obtendo-se 3 cortes. O segundo e terceiro cortes foram divididos ao meio e incluídos em resina acrílica resultando em 4 corpos de prova por dente. A solução de quitosana 0,2% (pH 3,2) foi preparada e distribuída em 3 frascos iguais de vidro (v1, v2 e v3) e em 3 de plástico (p1, p2 e p3) para realização dos testes em triplicata. Os testes de microdureza e colorimetria foram realizados durante seis meses nos períodos de 0, 7, 15, 30, 45, 60, 90, 120, 150 e 180 dias após o aviamento da solução. Para a mensuração da microdureza Knoop utilizou-se carga de 10 gramas por 15 segundos. O corpo de prova recebeu 50 μL da solução teste por 5 minutos e, após lavagem e secagem foi levado para mensuração. A análise foi realizada com as soluções v1, p1, EDTA 17% e água destilada (controle); v2, p2, EDTA 17% e controle; v3, p3, EDTA 17% e controle, para cada tempo proposto. Foram realizadas 3 endentações com espaço de 200 μm. As mensurações foram anotadas e arquivadas em um banco de dados. Para o teste da colorimetria utilizou-se uma solução padrão de carbonato de cálcio 0,3%, na qual gotejava-se por meio de micropipeta a solução de quitosana com volume pré determinado. A alteração da coloração da solução de carbonato, do violeta para azul, indicava quelação dos íons cálcio, detectada por meio de espectrofotometro Ultravioleta Visivel. O aparelho emitia um valor da absorbância para cada análise da coloração, expressa por meio de gráfico (comprimento de onda/absorbância). Empregou-se Análise de Variância (one-Way ANOVA) (α = 0,05) para comparar a microdureza entre as soluções, os diferentes tempos para cada solução, bem como a interação microdureza/tempo para cada solução. Houve semelhança entre as soluções testadas no que se refere ao tempo de estudo (p=0,113), bem como em relação à interação microdureza/tempo (p=0,329). As soluções testadas apresentaram, individualmente, o mesmo efeito sobre a microdureza da dentina, desde o tempo zero até os 180 dias. Quando comparadas entre si foram diferentes (p<0,0001). O teste de Tukey evidenciou que a quitosana (v1, v2, v3, p1, p2 e p3) e EDTA reduziram a microdureza de forma semelhante entre si (p>0,05) e diferente do controle (p<0,001). Os gráficos da análise colorimétrica mostraram que tanto a quitosana em vidro como a em plástico apresentaram valores médios de absorbância no mesmo comprimento de onda (234nm) para todos os tempos, enquanto que para a solução padrão de carbonato de cálcio o comprimento de onde foi de 206nm. Concluiu-se que independentemente da forma de armazenamento a quitosana apresenta propriedade quelante por um período mínimo de 6 meses.
Título en inglés
Study of the shelf life of chitosan stored at different flasks through colorimetry and dentine microhardness
Palabras clave en inglés
chitosan
microhardness
shelf life
Resumen en inglés
The aim of this study was evaluate, through the colorimetric titration method and analysis of the dentine microhardness, the shelf life of the solution of chitosan 0,2% stored in flasks of glass and plastic. Thirty human superior canines had their crown discarded and the cervical portion of the root sectioned, obtaining 3 sections. The second and the third sections were divided in half and included in acrylic resin resulting in 4 specimens per tooth. The chitosan solution 0,2% (pH 3,2) was prepared and distributed in 3 flasks of glass (v1, v2, v3) and in 3 of plastic (p1, p2, p3) to perform the test in triplicate. The tests of microhardness and colorimetry were performed during 6 months in the period of 0, 7, 15, 30, 45, 60, 90, 120, 150 and 180 days after the preparation of the solution. For the measurement of microhardness Knoop, it was used a load of 10 grams for 15 seconds. The test object received 50 μL of the test solution for 5 minutes and after washing and drying, it was taken out for measurement. The analysis was performed with the solutions v1, p1, EDTA 17% and distilled water (control); v2, p2, EDTA 17% and control; v3, p3, EDTA 17% and control, for each proposed time. Three indentations were performed with a 200μm space. Measurements were noted and filed in a database. For the colorimetric test, a standard solution of calcium carbonate 0.3% was used and a predetermined volume of chitosan solution was inserted to it by using a micropipette. The color changes observed in the carbonate solution, from violet to blue, indicated the chelation of calcium Ions, detected through visible ultraviolet absorbance spectrophotometry. The instrument generated a specific value of absorbance for each coloring solution analyzed, expressed through the graphic (wavelength/absorbance). Variation of analysis was used (One-Way ANOVA) (α= 0,05) to compare the microhardness among the solutions, the different time for each solution, as well as the interaction microhardness/time for each solution. The time of study was similar among the tested solutions (p=0,113), as well as the interaction between microhardness/time (p=0,329). The tested solutions showed, individually, the same effect over the dentine microhardness, from time zero until 180 days. When compared among each other the results were different (p<0,0001). The Tukey test demonstrated that chitosan (v1, v2, v3, p1, p2 and p3) and EDTA reduced the microhardness in a similar pattern among them (p>0,05) and different from the control (p<0,001). The graphics of the colorimetric analysis showed that either chitosan in glass or plastic presented medium values of absorbance in the same wave length (234nm) for all the different times, meanwhile the standard solution of calcium carbonate wavelength was 206 nm. It was concluded that independently of storing methods, the chitosan presents chelating property for a minimum period of six months.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-10-07
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.