Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.58.2014.tde-20032014-110028
Documento
Autor
Nome completo
Rafael Rezende Ribeiro
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Ribeirão Preto, 2014
Orientador
Banca examinadora
Pecora, Jesus Djalma (Presidente)
Estrela, Carlos
Sousa Neto, Manoel Damião de
Título em português
Avaliação das alterações morfológicas em canais radiculares curvos, promovidas pela instrumentação reciprocante, associada à instrumentação rotatória. Análise por microtomografia
Palavras-chave em português
anatomia interna
microtomografia computadorizada
molar inferior
Resumo em português
O objetivo do trabalho foi avaliar as alterações morfológicas bi, tridimensionais, e o transporte em canais mesiais de molares inferiores com curvatura acentuada. Selecionou-se molares inferiores com dois canais e forames independentes, livres de nódulos pulpares, reabsorção interna, tratamento endodôntico prévio, fratura radicular e dentro do padrão de raio e ângulo de curvatura, avaliados pelos exames radiográficos, tomográficos cone bean e microtomográficos. Partiu-se de 393 dentes para selecionar 15 dentro deste padrão morfológico. Esses dentes foram submetidos à microtomografia antes da instrumentação, após o preparo com instrumento Reciproc® R25 e após o preparo por cada lima dos sistemas de complementação (Mtwo e K3). Os dados morfométricos foram analisados pelo programa CTAn e as análises estatísticas foram realizadas utilizando o programa SPSS onde observou-se os seguintes resultados: a análise morfométrica bidimensional mostrou que a área e o perímetro apresentaram aumento gradual a cada milímetro avaliado, partindo do primeiro milímetro apical; houve também aumento gradual de área e de perímetro a cada troca de instrumento de acordo com o que se realizou o preparo biomecânico dentro dos conjuntos de grupos; houve diferença estatisticamente significante de área e de perímetro dos canais radiculares apenas após o preparo com os instrumentos #40 taper 04 e taper 02 (P<0,05). Em relação à distância do ápice, houve diferença estatística de área entre todos os milímetros avaliados (P<0,05). Em relação ao perímetro, não houve diferença entre os milímetros 1 e 2; e, 4 e 5 (P>0,05), entretanto com diferença entre o terceiro milímetro e os demais (P<0,05). As análises morfológicas tridimensionais de volume, área de superfície e SMI (Índice de Modelo Estrutural) do canal radicular, tiveram comportamento semelhante entre os grupos. Os espécimes submetidos à complementação, com instrumentos taper 04 e taper 02, não apresentaram diferença estatística após os preparos (P>0,05), com diferença entre os canais preparados com a R25 e os canais originais (P<0,05). Quando comparados os conjuntos de grupos, nenhum grupo análogo apresentou diferença estatística (P>0,05). Foi analisado o transporte por terços (cervical, médio e apical) e por todo o canal, não sendo detectada diferença estatisticamente significante (P>0,05) entre os terços, nem do canal todo entre a complementação pelos instrumentos taper 04 (Mtwo) e taper 02 (K3).
Título em inglês
Morphological changes in curved root canals promoted by the reciprocating instrumentation combined with rotary instrumentation. Analysis by microtomography
Palavras-chave em inglês
mandibular molar
micro-computer tomography
root canal anatomy
Resumo em inglês
The purpose of this study was to evaluate the two- and three-dimensional morphological changes, and the transportation that occurs in the mesial canals of mandibular molars with severe curvature. Molars were selected with two independent canals and foramina, no pulpal nodules, internal resorptions, previous endodontic treatment or root fracture and within the standard radius and angle of curvature evaluated by radiographs, cone-beam tomography and microtomography. From the 393 teeth initially selected, 15 fulfilled the selected parameters. The teeth were subjected to microtomography before instrumentation, after instrumentation with Reciproc® R25 and after preparation with each file of the complementary systems (MTwo and K3). The morphometric data were analyzed by CTAn software and the statistical analysis was performed using the SPSS software where the following results were observed. The two-dimensional morphometric analysis showed that the area and the perimeter presented a gradual increase for every evaluated millimeter, starting from the first apical millimeter. There was also a gradual increase in area and perimeter with each change of instrument according to the biomechanical within the sets of groups. There was a statistically significant difference in area and perimeter of root canals after the preparation with the instruments #40 taper 04 and taper 02 (P <0.05). Regarding the distance from the apex area, there was statistically difference among all evaluated millimeters (P <0.05). Regarding the perimeter, there was no difference between 1 and 2 mm, and 4 or 5 (P> 0.05), however with a difference between the third millimeter and the others (P <0.05). The three-dimensional morphological analyses of volume, surface area and root canal SMI (Structural Model Index) of the root canal showed a similar behavior among the groups. The specimens subjected to complementation to the instrumentation with instruments of tapers 04 and 02 showed no statistically significant difference after preparation (P> 0.05), with significant difference between the original and prepared canals (P <0.05). When comparing the sets of groups, no analogue group presented a statistically significant difference (P> 0.05). Transport was analyzed by thirds (cervical, middle and apical) and throughout the canal there, without statistically difference (P> 0.05) among the thirds or between groups with complementation with taper 04 (MTwo) and taper 02 (K3) instruments.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2015-04-23
 