Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.58.2009.tde-19022009-172102
Document
Auteur
Nom complet
Cristiane Savaris
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2009
Directeur
Jury
Dibb, Regina Guenka Palma (Président)
Alfredo, Edson
Bachmann, Luciano
Titre en portugais
Alteração de temperatura na dentina durante o procedimento restaurador com resina composta variando as fontes fotopolimerizadoras
Mots-clés en portugais
dentina
fotopolimerização
resina composta
temperatura
Resumé en portugais
O objetivo deste estudo foi avaliar a influência do tipo de fonte luminosa e da espessura do remanescente dental no aumento de temperatura na câmara pulpar durante a fotopolimerização de uma resina composta. Métodos: Utilizaram-se 96 fragmentos (6x7 mm) obtidos a partir das superfícies vestibulares de incisivos bovinos que foram divididos em 2 grupos e 4 subgrupos (n=12), de acordo com a fonte de luz (LED e luz halógena) e da espessura de remanescente dental (3,5 mm; 3,0 mm; 2,0 mm e 1,0 mm). Foram preparadas cavidades de classe I (3x2 mm), deixando a espessura dos respectivos remanescentes dentais, e restauradas com uma resina composta. A variação de temperatura foi captada por termopares posicionados na dentina do teto da câmara pulpar durante a fotopolimerização (20s) do agente adesivo e de cada incremento de resina composta. Foi considerado o maior valor de temperatura registrado durante todo o procedimento restaurador e também durante a fotopolimerização de cada incremento de resina composta. Os dados foram analisados usando ANOVA e Teste de Fisher (α=5%). Resultados: O LED promoveu maiores (p<0,05) valores de temperatura do que a luz halógena; os valores mais baixos de temperatura foram (p<0,05) para 3,5 mm de espessura e os maiores para os remanescentes de 1 mm de espessura de remanescente dental; não houve diferença significativa (p>0,05) entre as espessuras de 2,0 mm e 3,0 mm. O aumento de temperatura não foi significativo entre a luz LED e halógena durante a fotopolimerização do agente adesivo, no entanto, os valores registrados no decurso de cada compósito incremento fotopolimerizado foram estatisticamente superiores para a fonte de luz LED. Conclusões: o aumento de temperatura foi dependente do tipo de fonte de luz, da espessura do remanescente dental e do número de sucessivas fotoativações.
Titre en anglais
Temperature alteration in dentin according to the photopolymerization source during composite-resin restorations
Mots-clés en anglais
composite-resin
dentin
fotopolimerization
temperature
Resumé en anglais
Objective: to evaluate the influence of the type of light source and the thickness of remaining dentin on temperature rise in the roof of the pulp chamber during photopolymerization of a composite resin. Methods: 96 tooth fragments (6x7mm) obtained from buccal surfaces of bovine incisors were randomly divided into 2 groups and 4 subgroups (n=12) according to the light source (LED and halogen light) and the thickness of remaining tooth structure (3.5mm, 3.0mm, 2.0mm and 1.0mm). Class I cavities (3x2mm) were prepared, leaving the respective thickness of remaining tooth structure, and restored with a composite resin. Temperature rises were obtained by thermocouples positioned in dentin in the roof of the pulp chamber during photopolymerization (20s) of the adhesive agent and each composite resin increment. It was considered the highest temperature rise registered during the whole restorative procedure and also during photopolymerization of each composite resin increment. Data were analyzed using ANOVA and Fishers Test (α=5%). Results: LED promoted higher (p<0.05) temperature values than halogen light; temperature values were the lowest (p<0.05) for 3.5- mm-thick remaining and the highest for 1-mm-thick remaining; there was no difference (p>0.05) between thicknesses of 2mm and 3mm. Mean temperature rises were not significant between LED and halogen light during adhesive photopolymerization, however, values registered during each composite increment photopolymerization were statistically superior for LED unit. Conclusions: temperature rise was dependent on the type of light source, on the thickness of remaining tooth structure, and on the number of successive photoactivations.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2009-03-26
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.