Disertación de Maestría
DOI
https://doi.org/10.11606/D.58.2017.tde-14052015-113018
Documento
Autor
Nombre completo
Marina de Godoy Almeida Cintra
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2015
Director
Tribunal
Bataglion, Cesar (Presidente)
Matsumoto, Wilson
Raposo, Luís Henrique Araújo
Título en portugués
Estudo comparativo da reprodutibilidade do arco facial e de um novo dispositivo com nível de bolha para montagem de modelos maxilares em articulador semi-ajustável
Palabras clave en portugués
Arco facial
Articulador
Plano ocluso-craniano
Resumen en portugués
O arco facial tem seu uso descrito na literatura desde o início do século 20, e atualmente sua eficácia e precisão são controversas. Publicações recentes mostram que a sua reprodutibilidade é passível de erros. Este estudo teve como objetivo comparar a reprodutibilidade do arco facial com a de um novo dispositivo desenvolvido com nível de bolha para a montagem de modelos de gesso em articuladores semi-ajustáveis, por meio da análise de medidas realizadas com a Mesa de Erickson. Os modelos de gesso foram obtidos com moldes de alginato e montados em articulador semi-ajustável marca Bio-art, modelo a7 Plus. A avaliação da reprodutibilidade foi realizada em 10 participantes, com a obtenção de três montagens de seus modelos maxilares, sendo a primeira com o arco facial, a segunda com o dispositivo com nível de bolha estando o participante sentado e a terceira com o dispositivo com nível de bolha estando o participante em pé, cada método foi aferido 3 vezes, por 3 examinadores diferentes. Para cada montagem foram realizadas cinco medidas a saber: a) nas cúspides dos primeiros molares superiores de cada lado (dentes 16 e 26), b) cúspides dos caninos superiores de cada lado (dentes 13 e 23) e c) ponto interincisivo, localizado na linha média. Os valores obtidos foram submetidos ao Cálculo do Erro Técnico da Medida e ao Coeficiente de Variação interexaminador. O presente trabalho concluiu que o arco facial tem uma margem de erro em medidas repetidas maior do que o novo dispositivo desenvolvido. O novo dispositivo mostrou-se mais confortável para os participantes, mas necessita mais testes para avaliarmos sua eficiência.
Título en inglés
Comparative study of the reproducibility of the face bow and a new bubble level device for mounting maxillary casts semi-adjustable articulator
Palabras clave en inglés
Articulator
Face-bow
Occluded-cranial plane
Resumen en inglés
The face bow has been described in the literature since the early 20th century, and currently its effectiveness and accuracy are controversial. Recent publications show that the reproducibility is error-prone. This study aimed to compare the reproducibility of the face bow with a new device developed with bubble level for the assembly of plaster models in semi-adjustable articulators, through the analysis of measurements performed with Erickson table. The plaster models were obtained with alginate molds and mounted on semi-adjustable articulator brand Bio-art, a7 Plus model. Evaluation of reproducibility was conducted in 10 participants, obtaining three assemblies of their maxillary casts, the first one with the face bow, the second with the bubble level device with the participant being seated and the third level with the device bubble being the participant standing, each method was measured 3 times by 3 different examiners. For each assembly five measurements were performed as follows: a) in the cusps of the upper first molars on each side (teeth 16:26), b) cusps of upper canines on each side (teeth 13:23) and c) interincisal point, located in midline. The values obtained were subjected to measurement of the Technical Error Calculation and inter Coefficient of Variation. This study concluded that the face bow has a margin of error in repeated measurements greater than the newly developed device. The new device was more comfortable for the participants, but it needs more testing to evaluate their efficiency.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-08-09
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.