• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.58.2013.tde-07022013-142425
Document
Author
Full name
Júlia Olien Sanches
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2013
Supervisor
Committee
Dibb, Regina Guenka Palma (President)
Hotta, Takami Hirono
Martins, Vinícius Rangel Geraldo
Title in Portuguese
Influência dos tratamentos dessensibilizantes associados ao laser de diodo na permeabilidade dentinária
Keywords in Portuguese
Dessensibilizantes dentinários
Lasers de diodo
Permeabilidade da dentina
Abstract in Portuguese
Objetivo: Este estudo avaliou o efeito dos agentes dessensibilizantes associados ou não ao laser de diodo na permeabilidade dentinária e na morfologia da superfície. Materiais e Métodos: Para este estudo, 104 espécimes de dentina radicular bovina foram divididos aleatoriamente em 4 grupos e 2 subgrupos (n=13): G1A= nenhum tratamento (controle), G1B= laser de diodo, G2A= Oxagel, G2B= laser de diodo + Oxagel, G3A= Mi Paste, G3B= laser de diodo + Mi Paste, G4A= Sensitive Pró-Alívio dessensibilizante, G4B= laser de diodo + Sensitive Pró-Alívio dessensibilizante. Para análise da permeabilidade, 10 espécimes de cada grupo foram imersos em ácido clorídrico a 1% durante 20 segundos, 3 vezes, com intervalo de 2 horas entre as imersões, para exposição dos túbulos dentinários. A aplicação dos agentes dessensibilizantes foi feita de acordo com as instruções do fabricante e a irradiação com o laser de diodo foi feita no modo contato, comprimento de onda de 970 nm +/- 10 nm, potência máxima de 7 W CW, frequência de 10 Hz, durante 25 segundos. Em seguida, os espécimes foram submetidos à coloração histoquímica e seccionados para serem analisados quanto à permeabilidade por meio de microscopia óptica (MO). A permeabilidade dentinária foi dada pela porcentagem de penetração do corante em relação à área total do espécime seccionado. Os espécimes remanescentes (n = 3) foram utilizados para análise microscópica da superfície que foi dividida em duas áreas (controle e tratada). A exposição dos túbulos dentinários e a aplicação dos tratamentos foram realizadas da forma já descrita e, na sequência, os espécimes foram avaliados em microscopia eletrônica de varredura (MEV). Os valores obtidos de permeabilidade foram analisados através da ANOVA. Resultados: Nenhuma diferença estatística significante foi observada entre os tratamentos. Na microscopia eletrônica de varredura, foi observada uma ligeira diferença entre a área tratada e a área controle, exceto no grupo 4B. Comparando os grupos A e B (sem e associado ao laser, respectivamente), nenhuma mudança significativa foi notada na superfície dentinária. Conclusão: A aplicação dos agentes dessensibilizantes associados ou não ao laser diodo não influenciou na permeabilidade dentinária radicular e na morfologia da superfície dentinária.
Title in English
Influence of desensitizing treatments associated with diode laser on dentin permeability.
Keywords in English
Dentin desensitizing agents
Dentin permeability
Diode lasers.
Abstract in English
Objective: This study evaluated the effect of desensitizing agents associated or not with laser diode on dentin permeability and surface morphology. Materials and Methods: For this study, 104 bovine root dentin specimens were randomly divided into 4 groups and 2 subgroups (n = 13): G1A = no treatment (control), G1B= diode laser, G2A= Oxagel, G2B= diode laser + Oxagel, G3A= Mi Paste, G3B= diode laser + Mi Paste, G4A= Sensitive Pro-Relief desensitizing, G4B= diode laser + Sensitive Pro-Relief desensitizing. For permeability analysis , 10 specimens were immersed in 1% hydrochloric acid for 20 seconds, three times, with an interval of 2 hours between them, to expose the dentinal tubules. The application of desensitizing agents was performed according to the manufacturers instructions and the irradiation with the laser diode was made on contact mode, wavelength of 970 nm +/- 10 nm, maximum output 7 W CW, 10 Hz, for 25 seconds. After that, the specimens were imaged in an optical microscope (OM) and permeability was measured in the digitized images as the percentage of cooper ions penetration over the total area. The remaining specimens (n = 3) were used for surface microscopic analysis and they were divided in two areas (control and treated). The dentinal tubules exposure and the treatments application were performed as previously described and then analysed in scanning electron microscopy (SEM). The permeability values were analyzed using ANOVA. Results: No statistical significant difference among the treatments was observed. For scanning electron microscopy, there was a slight difference between the treated and control area, except for group 4B. Comparing groups A and B (without and associated with laser, respectively), no significant change was verified on the dentin surface. Conclusion: The application of desensitizing agents associated or not with diode laser did not affect the root dentin permeability and the dentin surface morphology.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2013-03-27
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.