• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.58.2007.tde-28032008-174332
Document
Author
Full name
Pâmela Carbone Mello
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2007
Supervisor
Committee
Ribeiro, Ricardo Faria (President)
Assunção, Wirley Gonçalves
Ferracioli, Renata Cristina Silveira Rodrigues
Title in Portuguese
Avaliação da resistência à abrasão, microdureza superficial e estabilidade de cor de dentes artificiais de resina acrílica
Keywords in Portuguese
Dentes artificiais
Estabilidade de cor
Microdureza superficial
Resistência a abrasão
Abstract in Portuguese
O objetivo deste trabalho foi avaliar in vitro a resistência a abrasão, a microdureza superficial e a estabilidade de cor de dentes artificiais de resina acrílica. Sete grupos (1- Biolux, 2- Trilux, 3- Blue Dent, 4- Biocler, 5- Orthosit-Vivodent, 6- Postaris-Antaris, 7- Gnathostar-Ivostar), compostos de 12 pre-molares superiores de cada fabricante, sendo 6 contra antagonistas metálicos (Ni-Cr) e 6 contra antagonistas de resina indireta (Solidex), foram delineados em um perfilômetro, antes e após serem submetidos ao ensaio de abrasão. A diferença linear entre a primeira e a segunda leitura foi medida com um paquímetro digital (precisao 0,01mm). Após a análise estatística (análise de variância, teste de Tukey-Kramer, nível de significancia em p<0,05), observou-se que houve diferenças estatísticas significantes entre os grupos e que a marca Postaris apresentou os menores valores de desgaste contra ambos os antagonistas (R=2,33±0,91µm e M=1,78±0,42µm). Para a análise da microdureza superficial Vickers, foram utilizados 6 incisivos laterais superiores de cada marca e 3 leituras (terços incisal, médio e cervical) foram feitas com o auxílio de um microdurômetro. As médias de microdureza superficial Vickers foram submetidas a análise estatística (nível de significancia p<0,05) e com os resultados obtidos concluiu-se que o grupo Biolux (22,1±0,91VHN) seguido do Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) e Biocler (21,0±1,80VHN) apresentaram maiores valores de dureza diferenciando-se do Vivodent (19,1±0,99VHN) e Blue Dent (18,9±1,54VHN), menos duros. Para o ensaio de estabilidade de cor foram utilizados 6 incisivos centrais superiores direitos de cada marca comercial (n=42), submetidos ao processo de envelhecimento artificial acelerado. O aparelho de leitura de cor utilizado foi um Espectrocolorímetro Portátil Modelo Color Guide 45/0 (BYK-Gardner, Alemanha). Cada dente teve sua cor lida antes e imediatamente após o ensaio de envelhecimento artificial. Os valores de ΔE foram submetidos a análise estatística com auxílio do programa JMP 5.1 (SAS Institute, EUA) e mostraram que houve diferenças estatisticamente significantes entres os grupos e que apenas a marca Blue Dent (4,37±0,32) apresentou valores de ΔE>3,3 considerado, segunda a literatura, clinicamente inaceitável. Para os grupos que tiveram alterações clinicamente aceitáveis, o grupo Antaris/Postaris teve a maior variação de cor (ΔE=2,73±0,96) e o grupo Biolux apresentou a menor variação de cor (1,39±0,27). Dentro das limitações da metodologia empregada, concluiu-se que o antagonista utilizado (metal ou resina) influencia a escolha do dente artificial, e que os dentes artificiais testados tem comportamentos diferentes quanto a resistência a abrasão, microdureza superficial e estabilidade de cor.
Title in English
Evaluation of the abrasion resistance, superficial microhardness and color stability of acrylic resin artificial teeth.
Keywords in English
Abrasion resistance
Artificial teeth
Color stability
Superficial microhardness
Abstract in English
The objective of this work was to evaluate in vitro the abrasion resistance, the superficial microhardness and the color stability of acrylic resin artificial teeth. Seven groups (1-Biolux, 2 - Trilux, 3 - Blue Dent, 4 - Biocler, 5 - Orthosit-Vivodent, 6 - Postaris-Antaris, 7 - Gnathostar-Ivostar), composed of 12 upper premolar for each manufacturer's, being 6 against metallic antagonists (Ni-Cr) and 6 against indirect resin (Solidex) antagonists, were delineated in a perfilometer, before and after the abrasion test. The linear difference between the first and the second readings was measured with a digital calliper (0,01mm precision). After the statistical analysis (variance analysis, Tukey-Kramer's test, p<0.05), it was observed that there were significant differences among the groups and that the trademark Postaris presented the smallest wear values against both antagonists (R=2,33±0,91µm and M=1,78±0,42µm). For Vickers superficial microhardness, 6 lateral upper incisors of each mark and 3 readings were used (incisal, medium, and cervical thirds) done with the microdurometer. The averages of Vickers superficial microhardness were submitted to the statistical analysis (p<0.05) and the obtained results show that the group Biolux (22,1±0,91VHN) followed by Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) and Biocler (21,0±1,80VHN) presented higher values, differing from Vivodent (19,1±0,99VHN) and Blue Dent (18,9±1,54VHN), less harders. For the color stability test 6 upper right central incisors of each commercial mark were used (n=42), submitted to the accelerated artificial aging process. The apparel for color reading was a Portable Spectruncolorimeter Model Color Guide 45/0 (BYK-Gardner, Germany). Each tooth had his color read before and immediately after the artificial aging. The ΔE values were submitted to the statistical analysis with JMP 5.1 (HEALTHY Institute, USA) software and show that significant differences were found among the groups and that only Blue Dent (4,37±0,32) presented clinically unacceptable values of ΔE (ΔE>3.3). For the groups that had clinically acceptable color alterations, the Antaris/Postaris group had the largest color variation (ΔE=2.73±0.96) and the Biolux group presented to smallest color variation (ΔE=1.39±0.27). Within the limitations of the methodology, was concluded that the antagonist (metal or resin) influence the choice of the artificial tooth, and that the tested artificial teeth have different behaviors for the abrasion resistance, superficial microhardness and color stability.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
me_Pamela_Mello.pdf (1.42 Mbytes)
Publishing Date
2008-07-10
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.