• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.58.2009.tde-26032010-144643
Document
Auteur
Nom complet
Hilmo Barreto Leite Falcão Filho
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2009
Directeur
Jury
Antunes, Rossana Pereira de Almeida (Président)
Ferracioli, Renata Cristina Silveira Rodrigues
Margonar, Rogério
Pinelli, Ligia Antunes Pereira
Souza, Raphael Freitas de
Titre en portugais
Análise da força de retenção de cimentos resinosos em modelo representativo da técnica de cimentação passiva para implantes osseointegráveis
Mots-clés en portugais
Materiais Dentários
Prótese Dentária Fixada por Implante
Retenção em Prótese Dentária
Resumé en portugais
O objetivo deste estudo foi analisar a força de retenção de dois cimentos resinosos utilizados na técnica de cimentação passiva para implantes osseointegráveis, Panavia F e RelyX U100, avaliando essa propriedade na sua aplicação em espécimes de três tipos de diferentes metais, NiCr (Verabond 2, Aalba Dental), NiCrTi (Tilite Ômega, Talladium) e Titânio (Ti c.p., grau 2, Realum), submetidos ou não à termociclagem. Noventa e seis cilindros calcináveis (Conexão Sistemas de Próteses) foram encerados de forma padronizada, fundidos (32 cilindros em cada tipo de liga) e cimentados sobre cilindros de titânio (Conexão Sistemas de Próteses). Os corpos-de-prova foram distribuídos em 12 grupos (n = 8) de acordo com o tipo de liga, cimento e ciclagem térmica. Todos os espécimes foram submetidos a imersão em água destilada a 37º C por 24 horas, entretanto apenas metade deles a um ensaio de termociclagem em uma máquina de simulação de ciclos térmicos MSCT-3 por 5000 ciclos durante 30 dias. Todos os corpos-de-prova foram submetidos a ensaios de tração em uma máquina de ensaios mecânicos EMIC-DL2000 (velocidade = 5mm / min e célula de carga = 500 Kgf ). A análise estatística evidenciou resistência de união à tração do cimento RelyX U100 superior ao cimento Panavia F, independente do tipo de metal utilizado, com médias de até 71,18 Kgf e 55,08 Kgf respectivamente. O ensaio de termociclagem não exibiu interferência na resistência de união de ambos cimentos.
Titre en anglais
Analysis of resin cement retention strength in a representative model of passive cementation technique for osseointegration implants
Mots-clés en anglais
Dental Materials
Dental Prosthesis
Dental Prosthesis Retention
Implant-Supported
Resumé en anglais
The aim of this study was to analyze the bond strength of two resin cements used in the passive cementation technique for osseointegrated implants, Panavia F and RelyX U100, evaluating this property on its application in specimens of three different metal types, NiCr (Verabond 2, Dental Aalba), NiCrTi (Tilite Omega, Talladium) and Titanium (Ti c.p., degree 2, Realum), submitted or not to termocycling assay. Ninety six calcined cylinders (Conexão Sistemas de Próteses) had been waxed of standardized form, casted (32 in each type of league) and cemented on titanium cylinders (Conexão Sistemas de Próteses). The specimens were distributed enter 12 groups (n = 8) in accordance with the type of metal, cement and thermocycling. All specimens were submitted to an immersion in distilled water at 37ºC for 24 hours, however only half of them to a termocycling assay in a simulation thermal cycles machine MSCT-3 for 5000 cycles during 30 days. All specimens were submitted to a tensile test in a mechanical test machine EMIC-DL2000 (speed = 5mm/min and cell load = 500Kgf). The statistics analysis evidenced tensile strength of the RelyX U100 cement greater than Panavia F cement independent of the metal league type used with averages until 71,18 Kgf and 55,08 Kgf respectively. The termocycling assay did not show interference in the tensile strength of both cements.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
do_Hilmo_Falcao.pdf (2.14 Mbytes)
Date de Publication
2010-10-08
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.