• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.58.2011.tde-21092011-150827
Documento
Autor
Nombre completo
Janisse Martinelli Borges de Oliveira
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2011
Director
Tribunal
Mattos, Maria da Gloria Chiarello de (Presidente)
Assunção, Wirley Gonçalves
Ferracioli, Renata Cristina Silveira Rodrigues
Neves, Flávio Domingues das
Sartori, Ivete Aparecida de Mattias
Título en portugués
Análise fotoelástica de tensões transmitidas a implantes curtos
Palabras clave en portugués
Fotoelasticidade
Implantes Curtos
Implantes Osseointegrados
Resumen en portugués
O objetivo desse trabalho foi avaliar, pelo método fotoelástico, de que maneira cargas aplicadas sobre próteses metalocerâmicas implantossuportadas eram transmitidas a implantes de diferentes comprimentos, e como a proporção coroa/implante influenciaria essa distribuição de tensões. A partir de quatro modelos mestres em resina do tipo policarbonato foram confeccionados quatro modelos em resina fotoelástica (Araldite) simulando extremidade livre mandibular, com o dente 44 em resina (Luxatemp) e os dentes 45, 46 e 47 substituídos por implantes com 4 mm de diâmetro. O grupo 1 (G1) foi formado por 2 implantes de comprimento convencional ou longo (11 mm; Titamax Cortical CM, Neodent) substituindo o 45 e o 46, e 1 implante curto (5 mm; Ws Cortical CM, Neodent) substituindo o 47. O grupo 2 (G2) apresentava 1 implante com 11 mm (45) e 2 implantes com 5 mm (46 e 47). O grupo 3 (G3) foi reabilitado por 3 implantes de 5 mm e o grupo 4 (G4) por 3 implantes de 11 mm de comprimento. Nos grupos com implantes de 5 mm foi simulada reabsorção óssea de 4 mm de altura. Coroas metalocerâmicas unidas foram parafusadas sobre os minipilares intermediários. Foram realizados diferentes carregamentos oclusais sobre as coroas: oclusal balanceado de 150N, puntiforme de 100N na mesial do 45 e puntiforme de 100N na distal do 47. Análise fotoelástica quantitativa determinou a tensão transmitida (MPa) nos grupos: G1 (84.73), G2 (136.36), G3 (126.77) e G4 (164.72) para a carga oclusal balanceada; G1 (91.66), G2 (70.93), G3 (93.08) e G4 (119.82) para a carga na mesial do 45; e G1 (75.22), G2 (70.88), G3 (93.79) e G4 (117.56) para a carga na distal do 47. Para os implantes curtos, em todos os casos, a proporção coroa/implante foi maior que 2,5 e para os implantes de comprimento convencional essa proporção foi 1, em média. Após as análises realizadas, foi possível concluir que os maiores valores de tensões foram encontrados no grupo com 3 implantes longos (G4), e o aumento da proporção coroa/implante não mostrou correlação com maior concentração de tensões. Comparativamente, a utilização de implantes curtos reduziu as tensões transmitidas ao redor dos implantes.
Título en inglés
Photoelastic analysis of tensions transmitted to short implants
Palabras clave en inglés
Fotoelasticity
Osseointegrated Implants
Short Implants
Resumen en inglés
The aim of this study was to evaluate by the photoelastic method, stress transmission to implants of different lengths by metal-ceramic crowns under different loads, and how crown/implant ratio influenced this stress distribution. From four matrixes, four photoelastic models (Araldite) were made simulating free mandibular end, with teeth 44 in resin (Luxatemp) and tooth 45, 46 and 47 replaced by implants with 4 mm in diameter. Group 1 (G1) was formed by two implants with conventional length or long (11 mm; Titamax Cortical CM, Neodent) replacing tooth 45 and 46, and one short implant (5 mm; Ws Cortical CM, Neodent) replacing the 47. Group 2 (G2) had one implant with 11 mm (45) and 2 implants with 5 mm (46 and 47). Group 3 (G3) was rehabilitated by three implants of 5 mm and group 4 (G4) for 3 implants of 11 mm in length. In the groups with 5 mm implants was simulated 4 mm bone resorption in height. Metal-ceramic fixed prosthesis was bolted on the abutments. Different oclusal loads were performed over the crowns, 150N in occlusal balanced, 100N on the 45 mesial, and 100N on the 47 distal. Quantitatively photoelastic analysis determined the stress transmitted (MPa) on the groups: G1 (84.73), G2 (136.36), G3 (126.77) and G4 (164.72) for the occlusal load balanced, G1 (91.66), G2 (70.93), G3 (93.08) and G4 (119.82) for charging on the 45 mesial, and G1 (75.22), G2 (70.88), G3 (93.79) and G4 (117.56) to the load on the 47 distal. Crown/implant ratio for short implants was greater than 2.5 and for long implants was about 1. After analysis, it was concluded that the highest values of strains were found in the group with three long implants (G4), and the increased crown/implant ratio showed no correlation with the highest stress concentration. Comparatively, the use of short implants reduced stress around the implants.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2012-09-25
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.