• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.58.2017.tde-17022016-170119
Documento
Autor
Nombre completo
Denise Pupim
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2015
Director
Tribunal
Mattos, Maria da Gloria Chiarello de (Presidente)
Brandini, Daniela Atili
Orsi, Iara Augusta
Souza, Valéria Oliveira Pagnano de
Vaz, Luís Geraldo
Título en portugués
Avaliação da alteração de rugosidade de superfície e dispersão de íons de ligas metálicas odontológicas submetidas a ensaio de tribocorrosão experimental
Palabras clave en portugués
Fundição
Íons metálicos
Ligas metálicas
Rugosidade
Tribocorrosão
Resumen en portugués
Este estudo teve como objetivo avaliar a alteração da rugosidade superficial e a dispersão de íons para o meio após tribocorrosão experimental das ligas CoCrMo, NiCr e NiCrTi, comercialmente utilizadas na fabricação de próteses odontológicas, utilizando solução de saliva artificial (Fusayama) como eletrólito com valores de pH 3,0; 6,5 e 9,0. Foram fundidas 15 amostras de cada liga (Ø13x2mm) por chama e 15 por máquina de fundição com atmosfera inerte de argônio, sendo cinco amostras para cada pH analisado. A tribocorrosão experimental foi realizada na configuração esfera sobre superfície, utilizando esfera de zircônia (Ø10mm), em equipamento de ciclagem vertical, simulando o movimento do ciclo mastigatório, com aplicação de 5N de carga e monitoramento do potencial de circuito aberto (OCP). O sistema operou a velocidade de 60 ciclos por minuto, totalizando 7500 ciclos após 15 minutos de ensaio, equivalente ao tempo de contato dental diário. Foi utilizada saliva artificial de pH 3,0; 6,5 e 9,0 e leituras de rugosidade de superfície foram realizadas antes e após os ensaios de tribocorrosão experimental em microscópio confocal a laser. A saliva utilizada foi armazenada em tubos de Falcon DNA-free e submetida à quantificação da dispersão de íons metálicos para a solução, por meio de análise de ICP-MS. O comportamento das ligas em contato com a esfera de zircônia durante o ensaio de tribocorrosão experimental realizado em potencial de circuito aberto foi alterado em função do pH do meio (P<0,001) e da técnica de fundição utilizada (P<0,001). Todas as amostras apresentaram tendência à repassivação após a remoção do contato com a esfera, indicando formação de novo filme protetor na superfície da liga. A liberação de íons foi maior nas amostras fundidas por chama e em contato com pH 3,0 (ácido), sendo o analito níquel liberado em maior concentração (P=0,010). Entretanto, os valores encontrados estão abaixo dos limites indicados como causadores de citotoxicidade e alterações celulares. Os resultados indicam que as amostras fundidas por chama apresentaram rugosidade de superfície estatisticamente maior que as fundidas por plasma (P=0,042), sendo observado nessas amostras a presença de defeitos na superfície e possíveis falhas de fundição que favorecem o processo corrosivo. O pH da saliva e a técnica de fundição exerceram influência sobre o comportamento de repassivação das ligas, rugosidade de superfície e quantidade de íons liberada para o meio, sendo os melhores resultados encontrados quando a técnica de fundição por plasma foi utilizada.
Título en inglés
Evaluation of changes in surface roughness and ion release from dental casting alloys after an experimental tribocorrosion process
Palabras clave en inglés
Casting
Metal alloys
Metallic ions
Roughnes
Tribocorrosion
Resumen en inglés
The aim of this study was to evaluate the changes in surface roughness and ions release to the environment after experimental tribocorrosion of CoCrMo, NiCr and NiCrTi alloys, commercially applied in dental prosthesis, using artificial saliva solution (Fusayama) as electrolyte with different levels of pH (3.0; 6.5 and 9.0). Fifteen samples were casted by flame from each alloy (Ø13x2mm) and 15 by plasma in a casting machine with an inert atmosphere (argon), five samples for each pH analyzed. The experimental tribocorrosion was performed in a ball-on-flat configuration, using a zirconia ball (Ø10mm) in vertical cycling equipment, simulating the masticatory cycle movement, applying 5N of load and recording the open circuit potential (OCP). The system operated at 60 cycles per minute, a total of 7500 cycles after 15 minutes, corresponding to the daily tooth contact. Artificial saliva at pH 3.0; 6.5 and 9.0 was used and surface roughness measurements were performed before and after the experimental tribocorrosion tests in a laser confocal microscope. After the tests, the saliva was stored in a DNA-free Falcon tubes and subjected to measurement of the ion release to the solution by means of ICP-MS analysis. The behavior of the alloys in contact with the zirconia ball during the experimental tribocorrosion performed in open circuit potential changed according to the pH (P<0.001) and the casting technique (P<0.001). All samples trended to repassivate when the ball contact was removed, indicating new formation of the protective film on alloy surface. The ion release was higher in the samples casted by flame and in contact with pH 3.0 (acid), nickel analyte being released in a higher concentration (P=0.010). However, the values found are below the limits specified to induce cytotoxicity and cellular changes. The results reflected that the samples casted by flame presented surface roughness statistically greater than those casted by plasma (P=0.042) and it was observed in these samples the presence of surface defects and possible casting flaws that enhance the corrosion process. The pH of the saliva and the casting technique presented influence on the repassivation behavior of the alloys, surface roughness and quantity of ions released into the environment, where the best results were found when the plasma casting technique was used.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-08-18
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.