Thèse de Doctorat
DOI
https://doi.org/10.11606/T.58.2011.tde-15082011-171203
Document
Auteur
Nom complet
Juliana Bisinotto Gomes Lima
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2011
Directeur
Jury
Orsi, Iara Augusta (Président)
Brandini, Daniela Atili
Costa, Marcio Magno
Gonçalves, Luiz Carlos
Mattos, Maria da Gloria Chiarello de
Titre en portugais
Análise da transmissão e distribuição de tensões aplicadas em próteses totais convencionais reembasadas com diferentes espessuras de forrador macio
Mots-clés en portugais
método dos elementos finitos
prótese removível
reembasadores resilientes
Resumé en portugais
Os materiais resilientes ou macios para reembasamento de base de próteses são utilizados na clínica odontológica com a finalidade de proporcionar maior conforto e eficiência mastigatória aos pacientes que utilizam próteses removíveis totais e que por situações específicas não suportam uma prótese removível total convencional com base rígida. Atualmente é muito utilizado nas próteses removíveis transicionais, para minimizar as pressões sobre implantes que se encontram na fase de osseointegração, além de proporcionar ausência de lesões traumáticas e condicionamento tecidual durante o período pós-cirúrgico; em casos de rebordo alveolar atrofiado; irritação crônica superficial possivelmente devido à pressão do forame mentoniano; rebordo em lâmina de faca; após radiação terapêutica dissipando as forças oclusais, entre outras. Assim, é objetivo deste estudo analisar por meio do método de elementos finitos tridimensional a distribuição de tensões aplicadas na prótese removível total reembasada com forradores macios em diferentes espessuras e consequente transmissão a mucosa e ao rebordo, definindo a espessura ideal de material reembasador. Os corpos-de-prova constituirão-se em modelos projetados de mandíbula desdentada com uma prótese total apoiada sobre o rebordo. São 6 modelos: modelo 1: prótese removível total apoiada diretamente sobre o rebordo sem material reembasador (caso controle); modelo 2: prótese removível total reembasada com 0,5mm de espessura de material reembasador apoiada sobre o rebordo; modelo 3: prótese removível total reembasada com 1mm de espessura de material reembasador apoiada sobre o rebordo; modelo 4: prótese removível total reembasada com 1,5mm de espessura de material reembasador apoiada sobre o rebordo; modelo 5: prótese removível total reembasada com 2,0mm de espessura de material reembasador apoiada sobre o rebordo; modelo 6: prótese removível total reembasada com 2,5mm de espessura de material reembasador apoiada sobre o rebordo. Uma força de 60N foi aplicada ao longo eixo dos dentes das próteses, sendo de mesma intensidade bilateralmente e simultaneamente. Após a execução dos teste e análise dos resultados verifica-se que a adição de apenas 0,5 mm de material reembasador (modelo 2), diminuiu em 10% o pico de tensão, ocorrendo diminuições menores com o aumento gradual da espessura de material reembasador. Dentro das características do presente trabalho, a diminuição dos picos são menores do que 1% entre os modelos 4 e 5, sugerindo que para mandíbulas com boa adaptação da prótese, superfície óssea lisa, sem espículas, nichos dentários ou outros fatores semelhantes, não é significativo uma espessura maior do que 1,5 mm de material reembasador . Um resultado que sai desse padrão se refere ao modelos 5 e 6, onde o aumento de 2 para 2,5 mm de espessura do material reembasador promoveu um aumento nos picos de tensão. Diante das características in vitro deste estudo conclui-se que uma espessura de 2mm de material reembasador é o suficiente para amortecer as forças mastigatórias. No presente estudo, espessura maior que 2mm promoveu tensões à mucosa e ao rebordo.
Titre en anglais
Analysis of Transmission and Distribution Voltages Applied to the Conventional Denture relined with a liner Soft
Mots-clés en anglais
finite element analysis
removable prosthesis
soft liners
Resumé en anglais
The soft or resilient materials for relining denture base are used in clinical dentistry in order to provide greater comfort and chewing efficiency of patients which use removable dentures for total and specific situations as they does not tolerate a removable prosthesis with total conventional rigid base. Currently it is widely used in transitional dentures, to minimize the pressures on implants in process of osseointegration, while providing no traumatic injuries and conditioning tissue during the postoperative period, in cases of atrophic alveolar ridge; superficial chronic irritation possibly due to pressure from the mental foramen, edging knife blade, and after radiation therapy dissipating occlusal forces. The aim of this study is to analyze through the three-dimensional finite element stress distribution applied in full removable denture rebased with soft liners in different thicknesses and consequent transmission to the mucosa and the edge, setting the ideal thickness of relining. The samples used in test form in models designed for edentulous mandible with a denture resting on the edge. There are 6 models: Model 1: Full removable denture supported directly on the alveolar ridge without relining (case control), Model 2: Full removable denture rebased with 0.5 mm thick relining resting on the alveolar ridge; Model 3: total removable prosthesis rebased with 1mm thickness relining resting on the alveolar ridge; Model 4: Full removable denture rebased with 1.5 mm thick relining resting on the alveolar ridge; Model 5: Full removable denture rebased with 2.0 mm thick relining resting on the alveolar ridge; Model 6: Full removable denture rebased with 2.5 mm thick supported on relining the alveolar ridge. A force of 60N was applied to the long axis of the tooth prosthesis, with the same intensity bilaterally and simultaneously. After execution of test and analysis of results shows that the addition of only 0.5 mm relining (model 2), down 10% peak tension, smaller decreases occurred with the gradual increase of the thickness of relining. Among the features of the present study, the decrease of the peaks are less than 1% between sections 4 and 5, suggesting that mandibles with good adaptation to the prosthesis, bone surface smooth, without spines, teeth or niches other similar factors, it is not a significant thickness greater than 1.5 mm relining. A result that comes out of this pattern refers to models 5 and 6, where the increase of 2 to 2.5 mm thick relining promoted an increase in spikes. The features of this in vitro study concluded that a thickness of 2mm relining is enough to absorb chewing forces. In this study, thickness greater than 2mm must transfer tension to the mucosa and alveolar ridge.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2012-04-11
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.