• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.58.2011.tde-15022012-134613
Document
Author
Full name
Tatiana Ramirez Cunha
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2011
Supervisor
Committee
Muglia, Valdir Antonio (President)
Duarte, Wagner Rodrigues
Souza, Raphael Freitas de
Title in Portuguese
Método simplificado versus convencional de confecção de próteses totais para aplicação na saúde pública. Parte III: avaliação da função mastigatória
Keywords in Portuguese
ensaio clínico controlado aleatório
habilidade mastigatória
mastigação
performance mastigatória
prótese total
Abstract in Portuguese
Métodos convencionais para a confecção de próteses totais envolvem uma série de procedimentos técnicos complexos. No entanto, métodos simplificados podem ser tão efetivos quanto os convencionais, porém é importante que a mastigação não sofra influências deletérias. Assim, o objetivo deste estudo foi comparar um método simplificado de confecção de próteses totais a outro convencional, tendo como variáveis a performance e a habilidade mastigatórias. A amostra foi formada por pacientes desdentados solicitando tratamento com próteses totais duplas. Os participantes foram divididos aleatoriamente em dois grupos: Grupo S (n=17), que recebeu próteses confeccionadas por um método simplificado, e Grupo C (n=18), que recebeu próteses confeccionadas de forma convencional. Após 3 meses da instalação das próteses, a performance mastigatória foi avaliada por um método colorimétrico, utilizando duas biocápsulas como alimento teste, após 20 e 40 ciclos mastigatórios, e a habilidade mastigatória dos participantes foi avaliada por meio de questionário (Questionário HM) e escala visual analógica (EVA). Foi feita referência dos resultados a um grupo de participantes dentados, Grupo DN (n=17). Os três grupos foram comparados por meio de testes adequados à distribuição dos dados (α=5%). A performance mastigatória foi similar nos grupos C e S e representou 31% daquela encontrada no grupo DN. A habilidade mastigatória foi semelhante para S e C independente do método de análise, sendo que algumas questões do questionário HM, analisadas isoladamente, tiveram maior ocorrência de respostas favoráveis para o primeiro. Conclui-se que métodos simplificados de confecção de próteses totais são capazes de reabilitar a mastigação de maneira comparável ao método convencional, tanto fisiologicamente como segundo as percepções do paciente.
Title in English
Simplified versus conventional method for complete denture fabrication for application in public health. Part III: Assessment of masticatory function
Keywords in English
complete denture
mastication
masticatory ability
masticatory performance
randomized controlled trial
Abstract in English
Complete denture fabrication involves a series of complex technical procedures. Nevertheless, simplified methods may be as effective as conventional ones and mastication should not be further impaired. Therefore, this study aimed to compare a simplified method and a conventional protocol for complete denture fabrication, in terms of masticatory performance and ability. A sample was formed by edentulous patients requesting treatment with maxillary and mandibular complete dentures. Participants were randomly allocated into two groups: Group S (n=17), which received dentures fabricated by a simplified method, and Group C (n=18), which received conventionally fabricated dentures. After 3 months following insertion, masticatory performance was evaluated by means of a colorimetric assay based on chewing two capsules as test food during 20 and 40 cycles. Masticatory ability was assessed by means of a questionnaire (HM) with dichotomous answers and a single question answered by means of a visual analogue scale (VAS). A third group (DN, n=17) formed by dentate volunteers served as an external comparator. Results for the three groups were compared by means of statistical tests suitable for the distribution of data (α=5%). Groups C and S presented similar masticatory performance which corresponded to 31% of group DN. Results for masticatory ability showed similarity between S and C, regardless of the assessment method, though some isolate items of the HM questionnaire showed more favorable results for the first group. It can be concluded that simplified methods for complete denture fabrication are able to restore masticatory function to a level comparable to the conventional protocol, physiologically and according to patient perceptions.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2012-09-26
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.