• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.58.2014.tde-02022015-103340
Document
Auteur
Nom complet
Marcelo Bighetti Toniollo
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2014
Directeur
Jury
Mattos, Maria da Gloria Chiarello de (Président)
Galo, Rodrigo
Matsumoto, Wilson
Silveira Júnior, Clebio Domingues da
Titre en portugais
Distribuição de tensões geradas por próteses esplintadas ou individualizadas sobre implantes com reabilitações em diferentes rebordos. Análise pelo método dos elementos finitos
Mots-clés en portugais
análise de elementos finitos
cerâmica
implantes dentários
prótese dentária fixada por implante
Resumé en portugais
O emprego dos implantes ósseointegráveis na odontologia moderna tem conquistado destaque nas reabilitações de forma crescente. Em casos de perda óssea vertical severa, a qual se faz bastante presente em áreas posteriores mandibulares, o uso de implantes curtos e de diâmetro reduzido se faz necessário. Para que a reabilitação mantenha o plano oclusal nivelado, utiliza-se próteses sobre implantes com proporção coroa/implante aumentada, sendo importante avaliar se há sobrecarga das estruturas de suporte, e se convém a esplintagem da infraestrutura reabilitadora. Um dos métodos utilizados atualmente para análise de distribuição de tensões na odontologia é o método dos elementos finitos. Assim, este estudo teve o objetivo geral de comparar o desempenho biomecânico de próteses, esplintadas (PSIE) ou individualizadas (PSII), sobre implantes cone Morse de comprimento regular e curto, em área posterior de mandíbula. Foram usados modelos geométricos tridimensionais de implantes regulares ∅ 4x11 mm e curtos - ∅ 4x5 mm alojados em rebordos representativos do hemi-arco mandibular esquerdo posterior envolvendo o dente 34 adjacente ao espaço anodôntico, desenhados no programa SolidWorks 2007. Os 8 grupos experimentais foram: grupo controle E (3 implantes regulares reabilitados com PSIE), grupo 1E (2 implantes regulares e 1 curto reabilitados com PSIE), grupo 2E (1 implante regular e 2 curtos reabilitados com PSIE) e grupo 3E (3 implantes curtos reabilitados com PSIE); grupo controle I (3 implantes regulares reabilitados com PSII), grupo 1I (2 implantes regulares e 1 curto reabilitados com PSII), grupo 2I (1 implante regular e 2 curtos reabilitados com PSII) e grupo 3I (3 implantes curtos reabilitados com PSII); As alturas dos pilares usados foram 3,5 mm para implantes regulares e 0,8 mm para implantes curtos. Foram simuladas forças oblíquas (45° - linguo-vestibular) de 365N em molares e 200N em prémolares. Análises qualitativas e quantitativas da distribuição de tensões máximas e mínimas principais (ossos cortical e esponjoso) e tensão equivalente de von Mises (implantes, componentes e infraestruturas) foram feitas por meio do programa AnsysWorkbench10.0. Os resultados obtidos permitiram concluir que o uso de PSIE propiciou uma série de vantagens e benefícios com relação à distribuição de tensões nos elementos envolvidos no sistema, sendo benéfica a todos os grupos experimentais do presente estudo, notoriamente ao grupo com presença apenas de implantes curtos, diminuindo as tensões no osso circunjacente aos implantes, principalmente em sua abrangência. Também diminuiu as tensões na superfície dos implantes, na área de transmucoso dos pilares/componentes, na região interna das infraestruturas e sua abrangência ao osso circunjacente aos implantes curtos nos grupos com implantes regulares e curtos. No entanto, nesse mesmo contexto, gerou maior tensão ao osso circunjacente aos implantes regulares intermediários comparativamente aos grupos individualizados. Também favoreceu a diminuição das tensões ao osso circunjacente ao dente adjacente, quando na presença de proporção coroa/implante aumentada. O uso PSII apresentou-se vantajosa na diminuição das tensões na parte superior dos pilares e na área de conexão entre coroas, além do grupo controle, apenas com implantes regulares e próteses de proporção normal, sendo viável sua utilização neste contexto frente às vantagens clínicas não oferecidas pelas próteses esplintadas.
Titre en anglais
Stress distribution generated by splinted or individualized implant prostheses with rehabilitation in different edges. A finite element analysis
Mots-clés en anglais
ceramics
dental implantation
dental prosthesis implant-supported
finite element analysis
Resumé en anglais
The use of dental implants in modern dentistry has gained prominence in oral rehabilitations. In cases of severe vertical bone loss, which is very much present in mandibular posterior areas, the use of short implants and reduced diameter is necessary. To maintain the occlusal plane level rehabilitation it is necessary the use of prostheses with increased crown/implant ratio , and it is important assess whether there is overhead of supporting structures, and befits splinting the rehabilitating infrastructure. One of the methods currently used to analyze the stress distribution in dentistry is the finite element method. Thus , this study has the overall objective to compare the biomechanical performance of prostheses, splinted (PSIE) or individualized (PSII) over Morse taper implants of regular and short length in the posterior area of the mandible. It were used three-dimensional geometric models of regular implants - ∅ 4x11 mm and short implants - ∅ 4x5 mm housed in representative edges of the posterior left mandibular hemi-arch tooth involving 34 teeth, designed in SolidWorks 2007 program. The 8 experimental groups were: control group E (3 regular implants rehabilitated with PSIE ), group 1E (2 regular and 1 short implants rehabilitated with PSIE) , 2E group (1 regular implant and 2 short implants rehabilitated with PSIE) and 3E group (3 short implants rehabilitated with PSIE); control group I (3 regular implants rehabilitated with PSII), group 1I (2 regular and 1 short implants rehabilitated with PSII), 2I group (1 regular implant and 2 short implants rehabilitated with PSII) and 3I Group (3 short implants rehabilitated with PSII); The pillars heights used for regular implants were of 3.5 mm and 0.8 mm for the short implants. Oblique forces (45° linguo-vestibular) were simulated in molars (365N) and premolars (200N). Qualitative and quantitative analysis of the distribution of maximum and minimum principal stresses (cortical and cancellous bone) and von Mises equivalent stress (implants, components and infrastructure) were made through the software AnsysWorkbench10.0. The results showed that the use of PSIE provided advantages and benefits regarding the stresses distribution in the elements involved in the system, being beneficial to all experimental groups of this study notoriously in the group with only short implants, reducing stresses in the surrounding bone to implants, especially in coverage. Also decreased the stresses on the implants surface, in the transmucosal abutments area, in the inner region of the infrastructure and its reach to the surrounding bone to short implants in groups with regular and short implants. However, in that respect, generated higher stresses to the surrounding bone of intermediate implants compared to the individualized groups. Also favoring a decrease of the stresses to surrounding bone adjacent to the tooth, in the presence of increased crown/implant ratio. The use PSII showed to be advantageous in reducing stresses on top of the abutments and the area of connection between crowns, and in the control group, only with regular implants and prostheses of normal crown/implant ratio, so it can be used in this context facing the clinical advantages not offered by splinted prostheses.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-11-13
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.