• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.55.2017.tde-06092017-173505
Document
Author
Full name
João Guilherme Vicente de Araujo
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2017
Supervisor
Committee
Helou Neto, Elias Salomão (President)
Andretta, Marina
Laureano, Estevão Esmi
Miqueles, Eduardo Xavier
Title in Portuguese
Reconstrução tomográfica de imagens SPECT a partir de poucos dados utilizando variação total
Keywords in Portuguese
SPECT; CSP; Reconstrução simultânea; Variação total
Abstract in Portuguese
Para realizar a correção de atenuação em uma tomografia computadorizada por emissão de fóton único (SPECT, em inglês) é necessário medir e reconstruir o mapa dos coeficientes de atenuação utilizando uma leitura de um tomógrafo de transmissão, feita antes ou simultaneamente à leitura de emissão. Essa abordagem encarece a produção da imagem e, em alguns casos, aumenta consideravelmente a duração do exame, sendo a imobilidade do paciente um fator importante para o sucesso da reconstrução. Uma alternativa que dispensa a leitura de transmissão é reconstruir tanto a imagem de atividade quanto o mapa de atenuação somente através dos dados de uma leitura de emissão. Dentro dessa abordagem propusermos um método baseado no algoritmo criado por Censor, cujo objetivo é resolver um problema misto de viabilidade côncavo-convexo para reconstruir simultaneamente as imagens. O método proposto é formulado como um problema de minimização, onde a função objetivo é dada pela variação total das imagens sujeita à viabilidade mista de Censor. Os teste foram feitos em imagens simuladas e os resultados obtidos na ausência de ruídos, mesmo para uma pequena quantidade de dados, foram satisfatórios. Na presença de dados ruidosos com distribuição de Poisson o método foi instável e a escolha das tolerâncias, nesse caso, ainda é um problema aberto.
Title in English
Tomographic reconstruction of SPECT images from few data using total variation
Keywords in English
SPECT; CSP; Simultaneous reconstruction; Total variation
Abstract in English
In order to perform attenuation correction in single photon emission computed tomography (SPECT), we need to measure and reconstruct the attenuation coefficients map using a transmission tomography scan, performed either sequentially or simultaneously with an emission scan. This approach increases the cost required to produce the image and, in some cases, increases considerably the scanning time, therefore the patient immobility is an important factor to the reconstruction success. An alternative that dispense the transmission scan is reconstruct both the activity image and the attenuation map only from emission scan data. In this approach we proposed a method based on the Censors algorithm, which objective is to solve a mixed convex-concave feasibility problem to reconstruct simultaneously all images. The method proposed is formulated as a minimization problem, where the objective function is given by the total variation of the images subject to Censors mixed feasibility. In the simulations, artificial images were used and the obtained results without noised data, even for small amount of data, were satisfactory. The method was unstable in the presence of Poisson distributed noise and the tolerance choice, in this case, is an open problem yet.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-09-06
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.