• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.54.1992.tde-21072009-172318
Document
Author
Full name
Dante Luis Chinaglia
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 1992
Supervisor
Committee
Hessel, Roberto (President)
Yoshida, Makoto
Zimmerman, Robert Lee
Title in Portuguese
O deslocamento do segundo ponto de cruzamento na curva de emissão eletrônica de polímeros com a dose de irradiação absorvida e suas implicações.
Keywords in Portuguese
Acelerador de elétrons
Curva de emissão
Emissão eletrônica
Teflon FEP
Abstract in Portuguese
Amostras de Teflón® FEP e Mylar C foram submetidas a um bombardeio eletrônico por longos períodos a fim de se verificar a existência de uma possível corrente de condução na fase final de um carregamento por feixe eletrônico. Em vez disso, descobriu-se que a energia associada ao segundo ponto de cruzamento da curva de emissão eletrônica do material bombardeado varia lentamente com o tempo de exposição à irradiação. Por outro lado foram descobertos também fortes indícios de que o centróide de carga sofre um deslocamento enquanto a amostra está sendo irradiada. A componente da corrente através da amostra, associada a qualquer um desses efeitos se superpõe à corrente de condução (se existir) e acaba tornando inviável a sua observação, enquanto um ou ambos os efeitos persistirem. Na realidade não é só a energia do segundo ponto de cruzamento que varia; toda a curva de emissão característica do material, que é fundamental para se entender os processos e carga e descarga de amostras, sofre modificação com a irradiação prolongada. Além disto, dois novos métodos para se carregar uma amostra de polímero estão sendo propostos. Um deles permite carregar uma amostra positivamente, por etapas, a tensões mais elevadas que o método convencional. O outro possibilita carregar negativamente uma amostra, lançando mão do mecanismo de auto-regulação para interrupção do processo de carga, o que só havia sido feito até o momento para um carregamento positivo. Um novo método para se descarregar uma amostra usando o próprio feixe eletrônico também é apresentado.
Title in English
The second cross over in the electronic emission curve shift with the absorbed radiation dose and its implication.
Keywords in English
Electron beam
Electronic emission
Emission curve
Teflon FEP
Abstract in English
Teflon® FEP and Mylar C samples were submitted to an electron beam during long periods of time in order to examine the possible existence of conduction current in the final stages of the charging process. It was found that the energy associated with the second crossover point in the electronic emission curve of the irradiated material varied slightly with the time of irradiation. On the other hand, strong evidence emerged that the charge centroid is shifted while the sample is being irradiated. The component of the current through the sample which is associated with any of these effects is superimposed to the conduction current (if present), hampering the identification of a conduction current. In fact, it is not only the energy of the second crossover point that varies, for the whole emission curve is modified upon prolonged irradiation. This emission curve is fundamental for understanding the charging and discharging processes in the samples. In addition, two new methods for charging a sample are being proposed. The first allows one to charge the sample positively to surface potentials that are higher than those obtained in the conventional method. The other method permits the sample to be charged negatively using the auto-regulation mechanism for interrupting the charging process; this had previously been done only for charging samples positively. A new method for discharging a sample using the electron beam is also presented.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2009-08-14
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.