Título en portugués
Determinação experimental da distribuição de dose de radiação em meio heterôgenio, irradiado por raios-x e gama radioterápicos
Palabras clave en portugués
dosimetria
dosimetria com filme
dosimetria de interface
heterogeneidade
Resumen en portugués
O estudo da distribuição de dose de radiação na região de separação entre dois meios de composições químicas diferentes, irradiados por feixes de fótons de alta energia empregados em radioterapia, tem sido restrito a situação em que o feixe de fótons incide perpendicularmente a superfície plana que separa os dois meios. Este trabalho apresenta um estudo bidimensional da distribuição de dose em um meio heterogêneo formado por água e alumínio, que simulam a interface entre tecido muscular e osso, irradiado por feixes de fótons de energias de 1,25 MeV e 10 MeV. A técnica de medida consiste em irradiar filmes radiográficos posicionados paralelamente a direção dos feixes, passando entre as bases de dois cilindros iguais de alumínio, com os eixos coincidentes, de raio menor que a largura do feixe. A distribuição de dose absorvida nos dois meios, no plano do filme, é medida em função da densidade btica apresentada pelos filmes, explorados por um microdensitômetro. Com isso pretendemos explorar a propriedade do filme de medir a dose de radiação com uma resolução espacial dificilmente igualada por outro tipo de dosímetro. Os resultados obtidos revelaram a existência de regiões onde ocorrem diferenças grandes entre a dose medida e a dose calculada sem considerar a heterogeneidade, coro é feito normalmente no cálculo de doses prescritas nos tratamentos. A comparação dos resultados obtidos no feixe de 1,25 MeV com os resultados de outros autores mostrou-se satisfatória, indicando que a técnica de medida, pouco utilizada nesse tipo de estudo, é bastante viável, principalmente se as informações contidas nos filmes forem totalmente processadas por um programa de computador desenvolvido para essa finalidade.
Título en inglés
Experimental determination of radiation dose distribution in an heterogeneous medium, irradiated with clinical beams of x and gamma rays
Palabras clave en inglés
Dosimetry
Film dosimetry
Heterogeneity
Interface dosimetry
Resumen en inglés
An experimental study of the perturbation caused by a cylindrical inhomogeneity of aluminium on dose distribution in a water phantom, irradiated by high energy photons used in radiation therapy, was performed, employing radiographic film as dosimeter. With these materials we intended to simulate the interface between bone and muscular tissue. The film was placed parallel to the beam axis, passing between the bases of two aluminium rods, with their axis being perpendicular to the film plane. This system was immersed in a cubic water phantom and irradiated by two photon beams: a gamma ray beam of a cobalt 60 source, and a 10 MeV bremsstrahlung X-ray, both produced by radiation therapy machines. By scanning the films in a computer controlled microdensitometer, the dose distributions were measured in the plane of the films. A previous study of the film response, showed that the optical density is proporcional to dose and film sensitivity is nearly the same in water and aluminium, under charged particle equilibrium condition. It was found that large errors occur when the inhomogeneity is ignored in dose calculation. A dose enhancement of about 9% and 11% in aluminium was observed, respectively, for the gamma and X rays beams. It was concluded that the film is good for this kind of measurements and may be employed in high energy photon beams, in particular, when high spatial resolution is needed. The method may be improved by the development of a software to fully exploit the microdensitometer-computer interface capability.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
JoseRocha_M.pdf (2.99 Mbytes)
Fecha de Publicación
2008-06-11
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.