Doctoral Thesis
DOI
https://doi.org/10.11606/T.54.1993.tde-10042015-114440
Document
Author
Full name
Rolando Fonseca Fernandes
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 1993
Supervisor
Committee
Zimmerman, Robert Lee (President)
Faria, Roberto Mendonça
Lejbman, Iuda Dawid Goldman Vel
Robilotta, Cecil Chow
Tannus, Alberto
Title in Portuguese
Espectros de energia de feixe de elétrons terapêuticos : correlação entre parâmetros físicos e qualidade
Keywords in Portuguese
Não disponível
Abstract in Portuguese
Apresentamos uma análise e medidas dos espectros de energia dos feixes de elétrons terapêuticos, relacionando-a com a qualidade destes feixes. Parâmetros clínicos e físicos, importantes nos planejamentos radioterápicos e dosimetria das radiações, são analisados detalhadamente a partir de suas definições e as suas dependências com a largura do espectro. As medidas e estudos foram efetuadas com dois acelerados lineares clínicos de modelos diferentes: Mevatron 74 (UNICAMP SP) e Mevatron 12 (HC/FMRP/Ribeirão Preto SP) produzindo feixes de energias nominais variando de 5 a 12 MeV para o primeiro e, 3 a 11 MeV para o segundo. Verificamos que os valores previstos pela teoria semi-empírica para os parâmetros clínicos diferem daqueles medidos. Essas diferenças são importantes quando enfocadas sob a visão do desenho dos aceleradores e os resultados clínicos desejados
Title in English
Not available
Keywords in English
Not available
Abstract in English
A new approach was described for clinical and physical parameters used in radiotherapy planning and dosimetry, studying their dependencies on spectral widths. Two different models of clinical linear accelerators were used-Mevatron 74 (UNICAMP/SP) and Mevatron 12 (HC/FMRP/Ribeirão Preto). Mevatron 74 produces beams with nominal energies from 5 up to 12 MeV and Mevatron 12 from 3 up to 11 MeV. It was verified that the values of cilinical parameters expected from a semi-empirical theory differ from that obtained experimentally. Such differences are relevant from the point of view of the design of electron accelerators, as wellas, of the target clinical results
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
RolandoFernandesD.pdf (6.22 Mbytes)
Publishing Date
2015-04-10
 
WARNING: Learn what derived works are clicking here.