Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.54.1992.tde-03092010-132508
Document
Auteur
Nom complet
Alvaro Macedo da Silva
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 1992
Directeur
Jury
Roda, Valentin Obac (Président)
Altafim, Ruy Alberto Corrêa
Garcia Neto, Alvaro
Titre en portugais
Monitor para caracterização de ruídos em redes de corrente alternada.
Mots-clés en portugais
Descarga atmosférica
Rede Elétrica
Ruído
Sobretensão
Surto de tensão
Resumé en portugais
Distúrbios em redes elétricas podem causar danos materiais e/ou operacionais em equipamentos eletrônicos sensíveis, em particular, sistemas em microcomputadores. Com o objetivo de registrar esses distúrbios, um monitor para redes elétricas foi desenvolvido. O equipamento desenvolvido é controlado por um microprocessador 80C86-2. Os seguintes distúrbios podem ser monitorados: desvios da freqüência nominal da rede, interferências de rádio freqüência, subtensão, sobretensão e surtos de tensão. Para minimizar o gargalo de Von Neumann, os circuitos foram projetados de forma que a maior parte das leituras é solicitada via interrupção. O equipamento foi testado a nível de laboratório e os resultados são apresentados.
Titre en anglais
Monitor to characterise electrical noise in alternate current network.
Mots-clés en anglais
Electrical network
Eletrical noise
Lightening
Overvoltage
Voltage surge
Resumé en anglais
Power line disturbances can adversely affect electronic sensitive equipment, particularly microcomputer based systems. In order to register these disturbances a power line monitor has been developed. The developed instrument is microprocessor based using a 80C86-2 as the main CPU. The following electrical disturbances can be monitored: nominal frequency deviations, radio-frequency interference, under and overvoltages, transient over voltages. Attempting to minimize Von Neumann´s bottle neck, the hardware was designed in such a way that most of the readings were requested through interrupts. The equipment was tested through a series of disturbance simulations, and the results are presented.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2010-09-08
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.