• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.54.1987.tde-02042015-161412
Document
Auteur
Nom complet
Mauro Henrique de Paula
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 1987
Directeur
Jury
Aegerter, Michel Andre (Président)
Chierice, Gilberto Orivaldo
Li, Maximo Siu
Vargas, Helion
Zimmerman, Robert Lee
Titre en portugais
Determinação de traços de metais por espectroscopia de deflexão fototérmica
Mots-clés en portugais
Não disponível
Resumé en portugais
Apresentamos um novo método de determinação quantitativa de traços em soluções aquosas. O método envolve a percolação das soluções em resina de troca catiônica Merck I e a análise por espectroscopia de deflexão foto térmica (E.D.F.). Amostras contendo cobre, cobalto e níquel apresentam excelentes características e permitem a detecção destes metais a nível de 9 ppb para o cobalto e 170 ppt para o cobre. O limite de detecção do níquel é semelhante ao do cobalto. Construímos o espectrômetro de deflexão foto térmica utilizado, que é descrito em detalhes, e que tem as seguintes características: deflexão mínima detectável, 10-8 rad; sensibilidade angular, 20 V/rad; variação mínima de temperatura detectável, 10-6°C; região espectral, 250-1600 nm. O efeito do espalhamento da luz nos sinais foto térmico é discutido.
Titre en anglais
Not available
Mots-clés en anglais
Not available
Resumé en anglais
We present a new method for quantitative analyses of traces in aqueous solution. The method involves the percolation of the solutions using a Merck I cationic exchange resin followed by an analysis by photothermal deflection spectroscopy (P.D.S.). Samples containing copper, cobalt and nickel present excellent characteristics and allow the detection of those metallic ions at levels down to 9 ppb (parts per billion) for cobalt ions and 170 ppt (parts per trillion) for the copper ions. The detection limit for nickel ions is basically the same as for cobalt. The analysis were performed with a homemade photothermal deflection spectrometer, described in detail, having the following characteristics : minimum detectable deflection, 10-8 rad; angular sensibility, 20 V/rad; lowest detectable sample temperature variation, 10-6°C; spectral range; 250 - 1600 nm. The effects of light scattering on photothermal signal is discussed
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-04-07
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.