• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.54.1986.tde-19032015-114437
Documento
Autor
Nombre completo
Hélio Cesar Nogueira Tolentino
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 1986
Director
Tribunal
Rodrigues, Antonio Ricardo Droher (Presidente)
Craievich, Aldo Felix
Cusatis, Cesar
Título en portugués
Espectrômetro para EXAFS dispersivo com focalização sagital
Palabras clave en portugués
Não disponível
Resumen en portugués
Um novo espectrômetro para estudo de EXAFS em laboratórios, com tubos convencionais de raios-X, é apresentado. Este equipamento faz uso de um monocromador curvo para focalização sagital e usa a divergência na outra direção para fazer a dispersão em energia, permitindo que todos os pontos do espectro sejam coletados simultaneamente. O desempenho do espectrômetro para EXAFS foi avaliado com monocromadores planos e curvos. Aspectos como resolução em energia, redução no tempo de aquisição dos dados experimentais e calibração de energia, foram abordados, mostrando que monocromadores com raios de curvatura tão baixos quanto 60mm apresentam praticamente a mesma resolução em energia que os planos. Nos testes foram utilizadas amostras de Cobre e filmes como detectores unidimensionais
Título en inglés
Not available
Palabras clave en inglés
Not available
Resumen en inglés
A new dispersive EXAFS spectrometer, for use with conventional laboratory x-ray sources, is presented. The equipment uses curved silicon monochromators for simultaneous focusing and dispersion of the available radiation, so that the whole spectrum is collected at one time. The performance of the spectrometer was studied with both curved and plane monochromators with respect to energy resolution, collection time reduction and energy calibration. The results show that there is practically no resolution deterioration, with respect to the plane monochromators, for radios of curvature as low as 60mm. For these tests x-ray films were used as linear detectors, which can be replaced by other low parallax unidimensional detectors, such as CCd type
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-03-20
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.