• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.54.1989.tde-02042014-104224
Documento
Autor
Nome completo
Luiz Telmo da Silva Auler
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Carlos, 1989
Orientador
Banca examinadora
Magon, Claudio Jose (Presidente)
Oliveira, Luiz Nunes de
Sartorelli, Jose Carlos
Título em português
Ressonância magnética nuclear em FexZn1-xF2
Palavras-chave em português
Fenômenos críticos
Magnetismo
RMN
Transição de fase
Resumo em português
Foi desenvolvido o aparato experimental necessário à realização de experimentos de RMN em baixas temperaturas, com o objetivo de investigar fenômenos críticos nos sistemas antiferromagnéticos diluídos FexZn1-xF2. Estudou-se a dependência do segundo momento da linha de ressonância do F0 com a temperatura, desde T ≈ TN até T ≈ 250K, através de medidas experimentais e simulações numéricas baseadas num modelo de campo médio. Também foi estudada a dependência angular da meia largura e da forma da linha. Os resultados das simulações numéricas concordam qualitativamente, mas não quantitativamente, com os resultados experimentais. Encontramos também a indicação de uma distribuição em T2 ao longo da linha de ressonância do F0, quando H0 é orientado perpendicularmente ao eixo C. O expoente crítico da magnetização do REIM foi medido diretamente a partir do segundo momento da linha do F0, após um esfriamento da amostra sem campo aplicado (Zero Field Cooling). O resultado obtido β=0.36 ± 0.01 concorda com o valor esperado β= 0.35
Título em inglês
Nuclear magnetic resonance in FexZn1-xF2
Palavras-chave em inglês
Critical phenomena
Magnetism
NMR
Phase transition
Resumo em inglês
The experimental apparatus required for Nuclear Magnetic Resonance low temperatures experiments was developed for the investigation of critical phenomena in the diluted antiferromagnetic FexZn1-xF2. The dependence of the second moment of the F0 resonance line with the temperature was studied from T ≈ TN to T ≈ 250K, both by experimental measurements and numerical mean field simulations. Angular dependence of the line width and line shape were also investigated. The numerically simulated results qualitatively agreed, but quantitatively didn´t agree with the experimental results. We found an indication of a distribution in T2 through the F0 resonance line, when H0 is oriented perpendicularly to the C axis. The magnetization critical exponent β of the REIM was measured directly from the second moment of the F0 resonance line, after a zero field cooling procedure. We obtained β= 0.36 ± 0.01 which is to be compared with the theoretical value β= 0.35
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
LuizTelmoAulerM.pdf (3.73 Mbytes)
Data de Publicação
2014-04-02
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.