• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.5.2013.tde-07082013-132341
Documento
Autor
Nombre completo
Luana Vilarinho Borges
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2013
Director
Tribunal
Hashimoto, Claudio Lyoiti (Presidente)
Silva, Ana Luiza Werneck da
Ribeiro, Adriana Vaz Safatle
Título en portugués
Comparação entre testes químico (o-toluidina) e imunoquímico de pesquisa de sangue oculto nas fezes e correlação com os achados colonoscópicos
Palabras clave en portugués
Colonoscopia
Guáiaco
Sangue oculto
Sensibilidade e especificidade
Testes imunológicos
Toluidinas
Valor preditivo dos testes
Resumen en portugués
Introdução: O sangramento colorretal é considerado um sinal de alarme e não deve ser ignorado. A perda de sangue pode não ser identificada pelo paciente, o que caracteriza a presença de sangue oculto. Este diagnóstico pode ser confirmado por testes de Pesquisa de Sangue Oculto nas Fezes (PSOF), através de métodos químicos ou imunoquímicos de identificação da hemoglobina. O resultado positivo de um teste de PSOF requer investigação complementar com colonoscopia, exame invasivo, de alto custo e que exige preparo intestinal. Justifica-se, portanto, a aplicação de um teste diagnóstico mais sensível e específico. No presente estudo, foram avaliados quatro diferentes testes de PSOF em 176 pacientes submetidos à colonoscopia e seus resultados foram comparados. Objetivos: 1) avaliar o grau de concordância entre os testes de PSOF e a colonoscopia. 2) avaliar a sensibilidade, a especificidade e os valores de predição dos testes químico e imunoquímico de PSOF, em pacientes submetidos à colonoscopia. Métodos: Pacientes com indicação de realizar colonoscopia foram submetidos também à PSOF pelo método químico (o-toluidina) e pelo método imunoquímico, empregando três kits comerciais disponíveis no mercado. Os pacientes foram avaliados quanto à indicação do exame colonoscópico, resultado da colonoscopia e uso de alimentos e medicamentos que pudessem interferir no resultado dos testes fecais. Fundamentado nos achados endoscópicos, a colonoscopia foi categorizada em positiva ou negativa, de acordo com a possível fonte de sangramento colorretal. O grau de concordância entre os testes de PSOF foi avaliado pelo índice Kappa. Resultados: Dos 176 pacientes, houve predomínio do sexo feminino (64,8%), com média de idade de 55,5 anos. As indicações clínicas mais frequentes para realização de colonoscopia foram alteração do hábito intestinal, doença inflamatória intestinal, dor abdominal e anemia. Os principais achados foram pólipos < 1 cm, doença diverticular não complicada do cólon e exame normal. Quarenta e quatro (25%) colonoscopias foram categorizadas como positivas quanto à fonte de sangramento colorretal. Observou-se concordância (p<0,05) entre todos os testes avaliados e a colonoscopia. O teste da o-toluidina apresentou concordância pobre (Kappa 0,03), enquanto os demais testes apresentaram concordância moderada (Kappa entre 0,43-0,48). O teste da o-toluidina revelou menor sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo em comparação aos testes imunoquímicos. Conclusões: Os testes imunoquímicos apresentaram melhores índices de concordância com a colonoscopia, quando comparados ao teste da o-toluidina. Os testes imunoquímicos revelaram maior sensibilidade, especificidade e valores de predição na detecção de sangramento colorretal
Título en inglés
Comparison between chemical (toluidine) and immunochemical faecal occult blood tests and correlation with the colonoscopic findings
Palabras clave en inglés
Colonoscopy
Guaiac
Immunologic tests
Occult blood
Predictive value of tests
Sensitivity and specificity
Toluidines
Resumen en inglés
Introduction: Colorectal bleeding is considered an alarm sign and should not be ignored. Blood loss can not be identified by the patient, which characterizes the presence of occult blood. This diagnosis can be confirmed by Faecal Occult Blood Testing (FOBT), through chemical or immunochemical methods. The positive outcome of a test requires complementary research FOBT with colonoscopy, an examination of invasive, costly and requires bowel preparation. It is justifiable, therefore, the application of diagnostic tests with better sensitivity and specificity. In the present study, we evaluated four different tests of PSOF in 176 patients undergoing colonoscopy and their results were compared. Objectives: 1) evaluate the degree of concordance between the PSOF tests and colonoscopy 2) assess the sensitivity, the specificity and the prediction values of the chemical and immunochemical FOBTs, in patients undergoing colonoscopy. Methods: Patients with indication of perform colonoscopy were subjected also to FOBT by the chemical method (toluidine test) and by the immunochemical method employing three commercial kits available in the market. Patients were evaluated regarding the indication of the colonoscopic examination, colonoscopy result, and use of foods and drugs that could interfere in the results of the faecal tests. Based on the endoscopic findings, the colonoscopy was rated as positive or negative, according to the possible colorectal bleeding source. The degree of accordance between FOBTs was evaluated by the Kappa index. Results: Among the 176 patients, there was a predominance of female gender (64.8%) with an average age of 55.5 years old. The most frequent clinical indication for colonoscopy were bowel habit changes, inflammatory bowel disease, abdominal pain and anemia. The main findings of colonoscopy were polyps <1 cm, uncomplicated colonic diverticular disease and normal exam. Forty-four (25%) colonoscopies were categorized as positive as to the possible source of colorectal bleeding. There was agreement (p<0.05) between all tests evaluated and the colonoscopy. The toluidine test presented poor accordance (Kappa 0.03), while the others showed moderate concordance (Kappa 0.43-0.48). The toluidine test showed less sensitivity, specificity, positive predictive value and negative predictive value compared to immunochemical tests. Conclusions: Immunochemical tests showed the best indexes of agreement with colonoscopy, when compared to the toluidine test. The immunochemical tests have shown greater sensitivity, specificity and predictive values in detecting colorectal bleeding
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2013-08-07
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.