• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.5.2009.tde-22032010-175407
Document
Auteur
Nom complet
Rodrigo Leal de Paiva Carvalho
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2009
Directeur
Jury
Casarotto, Raquel Aparecida (Président)
Anaruma, Carlos Alberto
Caromano, Fátima Aparecida
Titre en portugais
O uso de laser diodo de 830nm em cicatrizes pós-cirúrgicas de hérnia inguinal. Um estudo clínico
Mots-clés en portugais
Cicatrização de feridas
Hérnia inguinal
Lasers semicondutores/uso terapêutico
Terapia a laser de baixa intensidade
Resumé en portugais
Introdução: A Laserterapia de Baixa Intensidade (LTBI) é uma terapia que tem se mostrado eficiente na reparação tecidual em trabalhos com cultura celular e experimentos animais, mas existe uma escassez de trabalhos com cicatrização de incisões pós-cirúrgicas em humanos utilizando laser infravermelho GaAlAs de 830nm. O objetivo desse trabalho foi investigar a eficácia do laser infravermelho GaAlAs de 830nm no processo de cicatrização de incisão póscirúrgica de hérnia inguinal Métodos: 28 pacientes submetidos à cirurgia de hérnia-inguinal foram divididos randomicamente em grupo experimental (G1) e grupo controle (G2). O G1 recebeu tratamento com laser, sendo a primeira aplicação 24hs após a cirurgia e as demais dia sim dia não até um total de 4 aplicações. Ambos os grupos foram reavaliados após 6 meses por meio da Escala de cicatriz de Vancouver (ECV) e Escala visual analógica (EVA) e da espessura da cicatriz. As incisões foram irradiadas com laser diodo, =830 nm, 40 mW de potência de saída, 0,08cm² de diâmetro da ponteira de emissão, 26 segundos, 1,04J de energia por ponto e fluência de 13J/cm². Resultados: O G1 apresentou melhora significativa nas médias (p<0,05) da soma total da VSS 11 G1 2,14(±1,51) e G2 4,85(±1,87), na espessura G1 (0,11) e G2 (0,19) e na elasticidade da cicatriz G1 (0,14) e G2 (1,07). Conclusão: De acordo com os resultados obtidos nesse trabalho o tratamento com laser (830nm), usado na cicatrização de cirurgias de hérnia inguinal conseguiu melhorar a aparência e a qualidade da cicatriz seis meses após a incisão.
Titre en anglais
The use of 830nm diode laser in post-surgical scarring of inguinal hernia. A clinical study.
Mots-clés en anglais
Hernia inguinal
Laser therapy low-level
Lasers semiconductor/therapeutic use
Wound healing
Resumé en anglais
Background: Low Level Laser Therapy (LLLT) has been shown to be beneficial in the tissue repair process as shown in work done with tissue culture and animal experiments. However, there is a scarcity of work done with regard to post-surgical scarring of incisions in humans using infrared, 830nm, GaAlAs laser. The purpose of this study was to investigate the efficacy of an infrared, GaAlAs laser with a wavelength of 830nm in the post surgical scarring process after Inguinal Hernia Surgery. Method: 28 patients who underwent surgery for Inguinal Hernias were randomly divided into an Experimental Group (G1) and a Control Group (G2). The G1 received low level laser treatment (LLLT) with the first application being made 24 hours after surgery and then every other day for a total of 4 applications. Both Groups were re-evaluated after 6 months using the Vancouver Scar Scale (VSS), the Visual Analog Scale (VAS), and a measurement of scar thickness. The incisions were irradiated with an 830 nm diode laser operating with a continuous output power of 40 mW, spot size aperture of 0.08cm ², 26 seconds, an energy per point of 1.04J and energy density of 13J/cm ². Results: The G1 showed significantly better results; in the VSS totals (2.14±1.51) versus G2 (4.85±1.87), in the thickness measurements G1 (0.11 cm) versus G2 (0.19 cm), and in the pliability G1 (0.14) versus G2 (1.07). Conclusion: According to the results of this work LLLT (830nm) of Inguinal Hernia Scars resulted in better appearance and scar quality six months after surgery.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
RodrigoLealPCarvalho.pdf (689.32 Kbytes)
Date de Publication
2010-03-25
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.