• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.5.2008.tde-25032009-102004
Documento
Autor
Nombre completo
Alexandre Luque
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2008
Director
Tribunal
Seguro, Antonio Carlos (Presidente)
Crescentini, Milena Carlos Vidotto
Lucato, Jeanette Janaina Jaber
Título en portugués
Efeitos da estratégia da ventilação mecânica na função renal de ratos normais
Palabras clave en portugués
Insuficiência renal aguda
Inulina
Ratos Wistar
Respiração artificial
Respiradores mecânicos
Taxa de filtração glomerular
Resumen en portugués
A ventilação mecânica (VM) tem sido recentemente associada ao desenvolvimento de falências orgânicas distais, como um fator contribuinte para a falência renal em pacientes com trauma e fator de risco para diálise e mortalidade em unidade de terapia intensiva (UTI). A estratégia ventilatória adotada pode influenciar estes efeitos. O objetivo do presente estudo é explorar a hipótese de que a estratégia de ventilação mecânica adotada pode influenciar na função renal. Delineamento: Randomizado, investigação animal experimental. Casuística: Ratos machos Wistar, anestesiados, paralisados e ventilados mecanicamente. Intervenção: Dois grupos com seis animais cada foram randomizados para receberem ventilação mecânica com volume corrente (VT) de 8ml/kg (VT8) ou 27ml/kg (VT27). Os parâmetros ajustados para grupo foram: a) VT 8ml/kg; Freqüência respiratória (FR) 60±7 rpm; pressão positiva expiratória final (PEEP) 3 cmH2O; Pico de pressão inspiratória (Pwap) 11.8±2 cmH2O; Pressão média de vias aéreas (Pawm) 6,33±0,22 e b) VT 27ml/kg; FR 30±5 rpm; PEEP 0 cmH2O; Pwap 22.7±4 cmH2O; Pawm 6,50±0,22. Mensurações e Resultados: O grupo VT27 apresentou redução significativa no clearance de inulina após 60 minutos de VM, indicando insuficiência renal aguda (0.6±0.05 ml/min/100g de peso corporal (PC)), e ainda mais acentuada após 90 minutos de VM (0.45±0.05 ml/min/100g de PC) comparada aos valores basais (0.95±0.07 ml/min/100g de PC), p<0.001. Nenhum dos dois grupos sofreram variações significativas em relação as variáveis hemodinâmicas e gasométricas. Conclusões: Observamos que o ritmo de filtração glomerular (RFG) mensurado pelo clearance de inulina é afetado pela estratégia de volume corrente empregado após 60 minutos de VM com 27ml/kg e caindo a valores mais baixo após 90 minutos de VM
Título en inglés
Effects of mechanical ventilation strategy on renal function in normal rat model
Palabras clave en inglés
Acute renal failure
Artificial respiration
Glomerular filtration rate
Inulin
Mechanical ventilation
Wistar rats
Resumen en inglés
Mechanical Ventilation (MV) has been recently associated with development of distal organ failure and it is also a contributor factor for renal failure in trauma patients, and risk factor for dialysis and mortality rate in intensive care unit. The ventilatory strategy adopted might be influenced this effect. The aim of the present study was to explore the hypothesis that mechanical ventilatory strategy may contribute to decreased renal function. Design: Randomized animal laboratory investigation. Subjects: Anesthetized, paralyzed, and mechanically ventilated male Wistar rats. Interventions: Two groups of six rats each were randomized to receive tidal volume of either 8ml/kg or 27 ml/kg. Ventilation strategies for the two groups were as follows: a) 8ml/kg; frequency 60±7 beats/min; positive endexpiratory pressure, 3.0 cm H2O; and peak inspiratory airway pressure (Pawp), 11.8±2 cm H2O; and b) 27ml/kg; frequency 30±5 beats/min; positive end-expiratory pressure, 0 cm H2O; and peak inspiratory airway pressure (Pawp), 22.7±4 cm H2O; Both groups with the same mean airway pressure (Pawm), 6,33±0,21 and 6,5±0,22, respectively. Measurements and main Results: Rats ventilated with high tidal volume (27ml/kg) presented significantly decreased inulin clearance after 60 minutes of mechanical ventilation, indicating acute renal insufficiency (0.6±0.05 ml/min/BW) in comparison with basal values (0.95±0.07 ml/min/BW), p<0.001. We observed decreased in inulin clearance in rats that received high tidal volume, after 60 minutes of ventilation and even more significant at 90 minutes of ventilation (0.45±0.05 ml/min/BW) compared with basal values. No inulin clearance alteration was observed in control ventilation group (0.8±0.05 ml/min/BW basal vs. 0.72±0.03 ml/min/BW 120 min of MV). Conclusion: We concluded that GFR is affected by different strategies of mechanical ventilation, and after 60 minutes of high tidal volume (27ml/kg) ventilation the renal function marked decreased, getting worse after 90 minutes
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
alexandreluque.pdf (231.64 Kbytes)
Fecha de Publicación
2009-04-06
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.