• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.5.2008.tde-25032009-091656
Document
Auteur
Nom complet
Tatiana de Arruda Ortiz
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2008
Directeur
Jury
Tucci, Mauro Roberto (Président)
Rodrigues, Marcus Vinicius Herbst
Volpe, Márcia Souza
Titre en portugais
Influência do operador e do reanimador manual na manobra de hiperinsuflação manual: estudo em simulador do sistema respiratório
Mots-clés en portugais
Hiperinsuflação manual
Modalidades de fisioterapia
Terapia respiratória
Teste de materiais
Resumé en portugais
Introdução: A hiperinsuflação manual (HM) é uma técnica comum para facilitar a remoção de secreção traqueal de pacientes em UTI, e teoricamente, deveria ser realizada com uma insuflação lenta. Muitos fisioterapeutas não realizam a manobra com a insuflação lenta e os reanimadores manuais (RM) fabricados no Brasil possuem válvula de alívio de pressão, que não pode ser fechada na grande maioria desses dispositivos. Objetivos: Avaliar, em modelo mecânico, a influência da manobra de HM no volume corrente, picos de fluxo inspiratório e expiratório, e pressões alveolar e proximal por oito fisioterapeutas brasileiros, utilizando dois tipos de RM (com e sem válvula reguladora de pressão), de acordo com duas situações [conforme a prática clínica (PC) e após orientação de realizar a HM com a insuflação lenta, chamada de recomendada pela literatura (RL)], e em três cenários clínicos simulados (paciente normal, restritivo e obstrutivo). Resultados: Seis dos 8 fisioterapeutas realizaram a técnica com mais de duas insuflações; as pressões proximais geradas na situação RL foram menores devido aos menores picos de fluxo inspiratório. Os valores de pressões alveolares foram menores que 42,5 cmH2O (mediana = 13,9; intervalo interquartil:10,2-20,3) mesmo com altas pressões proximais (máximo 96,6 cmH2O, mediana 31,4; 19,2-44,8). Os volumes correntes foram menores do que os encontrados na literatura pesquisada (mediana = 514mL; 410-641). Os picos de fluxo inspiratórios (1,32; 0,92- 1,80) foram maiores que os expiratórios (0,88; 0,54-1,13) em quase todas as medidas. O pico de fluxo expiratório se correlacionou com o volume corrente: em cada cenário, os menores picos de fluxo expiratórios estavam correlacionados com baixos volumes correntes. Pressões, volumes e fluxos foram mais baixos com o RM com válvula reguladora de pressão. Conclusão: A manobra de HM foi realizada de forma diferente da preconizada na literatura; o RM com válvula reguladora de pressão gerou menores volumes, pressões e fluxos na maior parte dos cenários; as pressões proximais geradas não determinam, necessariamente, risco para o paciente, pois as pressões alveolares se mantiveram baixas
Titre en anglais
Influences of operator and manual resuscitator on manual hyperinflation maneuver. A lung model study
Mots-clés en anglais
Manual hyperinflation
Materials testing
Physical therapy modalities
Respiratory therapy
Resumé en anglais
Background: Manual hyperinflation (MH) is a common technique used for removing pulmonary secretions in ICU and theoretically should be performed with a slow inflation. Many Brazilian respiratory therapists do not perform the maneuver with a slow inflation and manual resuscitators (MR) made in Brazil have pressure relief valve (PRV) which in many of them cannot be closed to perform MH. Objectives: evaluate, in a lung model, the influence on tidal volume, inspiratory and expiratory peak flow, proximal and alveolar pressures of MH performed by eight Brazilian respiratory therapists using two types of MR (with and without pressure relief valve), in two manners [like clinical practice (CP) and after orientation to perform MH with a slow inflation, named literature recommended (LR)] and in three clinical simulated scenarios (normal, restrictive and obstructive patient). Results: Six of 8 respiratory therapists performed MH with two or more inflation. After instruction proximal pressure generated was lower because of the slower inspiratory peak flow. The alveolar pressure values were lesser than 42.5 cmH2O (median = 13.9; interquartile range: 10.2-20.3), despite of high proximal pressure (max 96.6 cmH2O, median 31.4; 19.2-44.8). Inspiratory tidal volume were smaller than other reports (median=514mL; 410-641). Inspiratory peak flow (1.32; 0.92- 1.80) were higher than expiratory (0.88; 0.54-1.13) in almost all measurement. Expiratory peak flow was correlated with tidal volume: for each scenario, the low expiratory peak flow was mainly generated by small tidal volume. Pressures, volumes and flows were lower with MR that uses PRV. Conclusion: In this small sample of respiratory therapists, MH was done different that literature recommends; MR whit pressure limiting system generate lower tidal volume, pressures and peak pressures in most scenarios; proximal pressure generated not determine, necessarily, risk for patient, because alveolar pressure was maintained low
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
tatianaaortiz.pdf (1.19 Mbytes)
Date de Publication
2009-03-27
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.