• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.5.2014.tde-22092014-151252
Documento
Autor
Nombre completo
Priscila Batista de Souza Amorim
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2014
Director
Tribunal
Stelmach, Rafael (Presidente)
Corso, Simone Dal
Lunardi, Adriana Claudia
Título en portugués
Avaliação objetiva dos hábitos e barreiras da atividade física de portadores de doença pulmonar obstrutiva crônica
Palabras clave en portugués
Acelerometria
Atividades cotidianas
Caminhada
Comportamentos saudáveis
Dispneia/diagnóstico
Dispneia/reabilitação
Doença pulmonar obstrutiva crônica/reabilitação
Estilo de vida sedentário
Exercício
Monitorização ambulatorial
Movimento
Participação do paciente
Questionários
Resumen en portugués
INTRODUÇÃO: Pacientes com doença pulmonar obstrutiva crônica (DPOC) tem atividade física reduzida. Barreiras que limitam a atividade física e a medida objetiva da limitação ainda são pouco estudadas nesta população. Conhece-las permite um planejamento adequado para incremento da atividade de vida diária (AVD). OBJETIVO: Comparar a AVD de portadores de DPOC e controles com um sensor de movimento, identificar barreiras que impedem a AVD e correlaciona-los à gravidade da dispneia, ao teste de caminhada de 6 minutos (TC6) e um escore de limitação da AVD. MÉTODOS: O número de passos, a distância percorrida em quilômetros e o tempo de caminhada foram registrados por um acelerômetro de bolso e um pedômetro durante 7 dias consecutivos. Um questionário de barreiras percebidas e a escala AVD (LCADL) foram utilizados para qualificar fatores que impedem a AVD. A dispneia foi medida por duas escalas distintas e a capacidade física submáxima pelo TC6. RESULTADOS: Foram avaliados 40 sujeitos com DPOC e 40 controles saudáveis. Os pacientes com DPOC realizaram tempo menor de caminhada (68,5 ± 25,8 minutos/dia vs. 105,2 ± 49,4; p < 0,001), menor distância (3,9 ± 1,9 km/dia vs. 6,4 ± 3,2; p < 0,001) e menor número de passos/dia. A falta de estrutura, influência social e falta de vontade foram as principais barreiras referidas para realização de AVD. O TC6 correlacionou-se com os resultados do acelerômetro, mas o LCADL não. CONCLUSÃO: Portadores de DPOC são menos ativos quando comparados a adultos saudáveis. Sedentarismo e as barreiras para atividade física tem implicação imediata na prática clínica indicando medidas de intervenção precoce
Título en inglés
Objective assessment of barriers and habits of physical activity in patients with chronic obstructive pulmonary disease
Palabras clave en inglés
Accelerometer
Activities of daily living
Dyspnea/diagnosis
Dyspnea/rehabilitation
Exercise
Health behavior
Monitoring ambulatory
Movement
Patient participation
Pulmonary disease chronic obstructive/rehabilitation
Questionnaires
Sedentary lifestyle
Walking
Resumen en inglés
INTRODUCTION: Patients with chronic obstructive pulmonary disease (COPD) have reduced physical activity. Barriers that limit physical activity and objective measures of limitation are poorly studied in this population. The knowledge of them allows a proper planning for increased physical activity. OBJECTIVES: To compare ADLs in COPD patients and controls using a motion sensor, identify perceived barriers that prevent AVD and correlate them to the severity of dyspnea, to the 6-minute walk test (6MWT) and a score of AVD limitation. METHODS: An pocket accelerometer and a pedometer recorded the number of steps, distance in Km and walking time for seven consecutive days. A survey of perceived barriers and the ADL scale (LCADL) were used to describe factors that prevent AVD. Dyspnea was measured by two different scales and submaximal exercise capacity by 6MWT. RESULTS: 40 subjects with COPD and 40 healthy controls were evaluated. Patients with COPD performed less time walking (68.5 ± 25.8 minutes / day vs. 105.2 ± 49.4; p < 0.001), shorter distance (3.9 ± 1.9 km / day vs. 6.4 ± 3.2; p < 0.001) and a smaller number of steps/day. The lack of infrastructure, social influences and unwillingness were the main barriers to performing ADLs. The 6MWT correlated with the results of the accelerometer, but not LCADL. CONCLUSION: Patients with COPD are less active compared to healthy adults. Sedentary and barriers to physical activity has immediate implications in clinical practice indicating early intervention measures
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-09-23
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.