• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.5.2006.tde-16102006-133859
Document
Author
Full name
Luís Henrique Ishida
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2006
Supervisor
Committee
Besteiro, Julio Morais (President)
Cunha, Marcelo Sacramento
Faria, José Carlos Marques de
Title in Portuguese
"Estudo anatômico comparativo entre o retalho escapular e o retalho perfurante da artéria toracodorsal"
Keywords in Portuguese
Artérias/anatomia & histologia
Axila/anatomia & histologia
Cirurgia plástica
Microcirurgia
Procedimentos cirúrgicos reconstrutivos
Retalhos cirúrgicos
Abstract in Portuguese
Desde a primeira descrição do retalho perfurante de artéria toracodorsal (TAP), sua indicação tem sido questionada por se tratar de um retalho de características semelhantes aos retalhos fasciocutâneos escapulares baseados na artéria circunflexa escapular, que são bem conhecidos e reprodutíveis. Este estudo visa comparar características anatômicas destes dois retalhos, distinguindo-os para uma melhor indicação. Adicionalmente o estudo visa estudar o posicionamento do pedículo perfurante do retalho TAP. Vinte e um pares de retalhos (TAP e escapular) foram dissecados simultaneamente em cadáveres frescos. Os músculos latíssimo do dorso e redondo maior foram seccionados e os dois retalhos foram retirados em peça única. O comprimento do pedículo, diâmetro externo da artéria e da veia, espessura da derme e espessura do tecido celular subcutâneo de ambos os retalhos foram avaliados e comparados de forma pareada. A localização dos pedículos dos retalhos foi avaliada em ambos os retalhos. Os dados obtidos foram analisados estatisticamente através do teste t de Student. O retalho TAP apresentou um pedículo com média de 16,95 cm de comprimento, sendo 50% maior que o do retalho escapular (p<0,05). A espessura média da derme foi 2,12 mm, sendo 42% mais fina do que a do retalho escapular; e a do tecido subcutâneo foi 1,37 cm, sendo 28% mais fina do que a do retalho escapular (p<0,05). O pedículo do retalho TAP apresentou artéria com diâmetro médio de 3,14 mm e veia com diâmetro médio de 3,03 mm, enquanto o pedículo do retalho escapular apresentou artéria com diâmetro médio de 3,33 mm e veia com diâmetro médio de 2,95mm, ambos sem diferenças estatísticas. Nas dissecções estudadas, todos os pedículos dos retalhos escapulares se localizavam no “espaço triangular". Já a localização dos pedículos perfurantes do retalho TAP não apresentou nenhum parâmetro constante. O estudo demonstrou que, apesar de se localizarem em sítios anatômicos adjacentes, o retalho TAP possui um pedículo mais longo e sua pele é mais fina do que o retalho escapular. Por outro lado, o posicionamento do pedículo do retalho escapular é constante, enquanto o pedículo perfurante do retalho TAP possui localização variável.
Title in English
Comparative anatomical study between the thoracodorsal artery perforator flap and the scapular flap
Keywords in English
Arteries/anatomy & histology
Axilla/anatomy & histology
Microsurgery
Reconstructive surgical procedures
Surgery plastic
Surgical flaps
Abstract in English
Indication of the thoracodorsal artery perforator (TAP) flap has been questioned because its characteristics are similar to those of scapular flaps based on the scapular circumflex artery. The scope of this study is to compare the anatomic features of these two flaps, differentiating them for a better indication. Twenty-one pairs of flaps (TAP and scapular) were dissected simultaneously in fresh cadavers. The length of the pedicles, thickness of the arteries and veins of the pedicles, and the thickness of the dermis and subcutaneous tissue of the flaps were assessed and compared. The position of the pedicles of both flaps was evaluated. The average length of the TAP flap pedicle was 16.95 cm, and it was 50% longer than the scapular flap (p<0.05). The mean thickness of the dermis was 2.12 mm and of the subcutaneous tissue 1.37 cm, respectively 42% and 28% thinner than the scapular flaps (p<0.05). No significant difference was evident between the thicknesses of the pedicles. The TAP arterial pedicle was 3.14 mm and the venous one 3.03 mm. The scapular flap demonstrated a 3.33 mm arterial pedicle and 2.95 mm for the venous one. The evaluation of the position of the pedicle of the scapular flap was constant; on the other hand, the perforator pedicle of the TAP flap did not show any constant anatomical parameter. The study revealed that although the TAP flap and the scapular flap lie in adjacent anatomical areas, the TAP flap has a longer pedicle and a thinner skin; their vascular pedicles have similar thickness; though the position of the thoracodorsal perforator pedicle is variable, when compared with the scapular flap.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2006-10-20
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.