• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2012.tde-09012013-145337
Documento
Autor
Nombre completo
Luis Alberto Saraiva Santos
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2012
Director
Tribunal
Moreira, Luiz Felipe Pinho (Presidente)
Sannomiya, Paulina
Braile, Domingo Marcolino
Silva, José Pedro da
Vicente, Walter Villela de Andrade
Título en portugués
Estudo experimental comparativo entre a derivação cavo-pulmonar associada ao suporte circulatório esquerdo e o suporte circulatório biventricular na falência aguda biventricular
Palabras clave en portugués
Coração auxiliar
Derivação cardíaca direita
Disfunção ventricular direita
Insuficiência cardíaca
Suínos
Resumen en portugués
Introdução: A falência do ventrículo direito (VD), durante o emprego de dispositivos de assistência circulatória do ventrículo esquerdo (DAVE), pode resultar em severo compromisso hemodinâmico com altas taxas de mortalidade. Objetivo: Este estudo avaliou o desempenho hemodinâmico e as alterações miocárdicas decorrentes do emprego de dispositivo de assistência ventricular esquerda, associado ou não à descompressão do ventrículo direito (VD) através de derivação cavo-pulmonar.Estes achados foram comparados com o emprego de assistência circulatória esquerda isolada e com a assistência circulatória biventricular, em modelo experimental de falência cardíaca. Métodos: O suporte ventricular esquerdo foi instalado por meio de bomba centrífuga em vinte e um suínos (25-32 kg) com falência biventricular severa obtida pela indução de ritmo de fibrilação ventricular (FV). Os animais foram randomizados em três grupos. No grupo Controle, foi implantado apenas o DAVE. No grupo Derivação, além do DAVE foi realizada a cirurgia de Glenn modificada, com anastomose de tubo de Politetrafluoroetileno expandido (PTFE) n° 16, entre a veia cava superior e o tronco da artéria pulmonar. No grupo Biventricular, foram instaladas duas bombas centrífugas em paralelo, uma do lado esquerdo e outra do lado direito do coração. Foram monitoradas as pressões intracavitárias no momento prévio à indução de FV e a cada 30 minutos de assistência até o limite de 180 minutos. Lactato venoso e dosagens de citocinas inflamatórias também foram coletados em momentos distintos no inicio da FV e a Intervalos regulares de uma hora até o final do experimento Amostras do endocárdio dos dois ventrículos foram coletadas e analisadas por meio de microscopia óptica e eletrônica Resultados: manutenção do ritmo de FV foi responsável por detenoração hernodinâmica Importante no grupo Controle e no grupo Derivação A diferença observada entre o fluxo do DAVE nos grupos Derlvação e Controle (+55±14 ml/kg/mln p=O 072) não foi significativa ao passo que o fluxo no grupo Biventricular for significativamente maior (+93±17 ml/kg/mln p=0.012) e se manteve estável durante o experimento A PAM se manteve constante apenas no grupo Biventricular (p
Título en inglés
Comparative experimental study between cavopulmonary anastomosis associated with left ventricular assist device support and biventricular circulatory assistance in acute biventricular failure
Palabras clave en inglés
Pigs
Right ventricular
Resumen en inglés
Background Right ventricular (RV) failure durinq left ventricular assist device (LVAD) support can result in severe hernodynarnic cornpromise with hiqh mortality. Objective: This study investiqated the acute effects of cavopulmonary anastomosis on L VAD performance and riqht ventricular myocardial compromise in comparison with isolated LVAD support and biventricular circulatory support in a model of severe cardiac failure. Methods: LVAD support was performed by means of centrituqa pump implantation in 21 anesthetized guinea piqs (25-32 kg) with severe biventricular failure achieved by ventricular fibrillation (VF) induction. Animais were randomized in three groups In the Control group, isolated LVAD support was performed In the Cavopulmonary group, cavopulmonary anastomosis was established by connecting the superior vena cava ano pulmonary main artery with a short segment of expanded politrafluorotylen no. 16 (rnodified Glenn shunt). In the Biventricular group, biventricular assist device support was established by means of two parallel centrifugal: pumps, one of them on the riqht-hand side of the heart and the other on the left-hand side. They were maintened under circulatory support and hemodynamic monitoring for 3h. Blood sample was collected before VF and in intervals of 30 minutes until the end of the surgery. Venous lactate and cytokines serum levels derterminations were also obtained, before VF and each hour. Endocardium samples of the septum and two ventricles were collected and analyzed by optics and electronic in microscopy. Results: Ventricular fibrillation maintenance was responsible for acute LVAD performance impairment after mino in the Control and Cavopulmonary groups. Cavopulmonary anastomosis resulted in non-significant improvement of LVAD pump flow in relation to control group (+55±14 ml/kg/min, p=0.072), while animais under biventricular support maintained higher LVAD flow performance (+93±17 ml/kg/min, p=0.012). Mean arterial pressure remained constant only in biventricular group (p<0.001), which also presented significant decrease of right atrial pressure (p=0,043). Similar increases in cytokine levels were observed in the three groups while the serum lactate presented lower level only in the Biventricular group (p=0,014). Ultrastructural analysis documented the presence of lower levels of myocardial cellular swelling in right ventricle in the Biventricular group . (p=0.017). Conclusion: The concomitant use of cavopulmonary anastomosis during LVAD support in a pig model of severe biventricular failure resulted in non-siqnificant improvement of hemodynamic performance and it did not effectively replace the use of biventricular support. Cytokine levels were similar in three groups. The Biventricular group showed lower levei of cellular swelling in the right ventricle.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2013-01-15
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.