• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2011.tde-23082011-132143
Documento
Autor
Nombre completo
Fábio Yuji Hondo
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2011
Director
Tribunal
Maluf Filho, Fauze (Presidente)
Bresciani, Claudio Jose Caldas
Cecconello, Ivan
Gagliardi, Danilo
Rocha, Julio Rafael Mariano da
Título en portugués
Estudo experimental comparativo de métodos de diérese tecidual no tratamento endoscópico do divertículo faringo-esofágico
Palabras clave en portugués
Divertículo de Zenker
Endoscopia gastrointestinal/métodos
Estudos experimentais
Modelos animais
Terapia por ultrassom/instrumentação
Resumen en portugués
O divertículo faringo-esofágico (DFE), também conhecido como cricofaríngeo ou de Zenker (DZ), é doença rara, com prevalência estimada entre 0,01% e 0,11%, e que acomete os muito idosos, para os quais tratamentos menos invasivos podem ser úteis, destacando-se o endoscópico. A despeito das inovações com equipamentos e acessórios, hemorragias e perfurações ocorrem em até 10 e 15% dos pacientes, respectivamente. A constatação de divertículo faríngeo em porcos domésticos transformou-se em modelo experimental de grande interesse para fins didáticos e científicos. Pretendeu-se, neste sentido, introduzir inovação técnica e compará-la com o tratamento endoscópico convencional do DFE. O objetivo deste estudo foi comparar, em modelo experimental, a diérese do septo do DFE efetuada através do bisturi harmônico Ultracision ® (Grupo U) com a do eletrocautério monopolar (Grupo M). Foram utilizados 20 porcos domésticos com peso médio de 20,2 Kg (±1,35). Os animais foram alocados entre os grupos M e U de forma não aleatorizada. Não houve diferença significativa quanto ao tamanho do divertículo (p=0,0897) ou quanto ao tempo de inserção do diverticuloscópio flexível (p=0,7387). No grupo U, o tempo médio para a incisão do septo e o tempo total do procedimento foram menores (p<0,0001) para as duas comparações. Quanto à extensão da borda seccionada, houve diferença significativa (p=0,0047) entre os grupos, com maior média de tamanho no grupo U. Em relação aos parâmetros microscópicos, apenas a extensão da lesão provocada pela corrente monopolar (Grupo M) foi maior (p<0,0001). Em relação aos parâmetros de profundidade e à presença de inflamação, não houve diferença entre os grupos. Observou-se hemorragia apenas no grupo M (p=0,01), sempre controlada endoscopicamente. Em comparação com a técnica de seção feita com uso de estilete endoscópico e corrente monopolar mista, a diverticulotomia endoscópica experimental com uso de diverticuloscópio flexível e bisturi harmônico se mostrou mais rápida e relacionada com menor dano tecidual
Título en inglés
Experimental study comparing two methods of tissue diaresis for endoscopic treatment of pharingoesophageal diverticulum
Palabras clave en inglés
Animal models
Experimental models
Gastrointestinal endoscopy/methods
Ultrasonic therapy/instrumentation
Zenker diverticulum
Resumen en inglés
The pharyngoesophageal diverticulum (PED), also known as cricopharyngeal or Zenker diverticulum (ZD), is a rare disease with estimated incidence ranging from 0.01% to 0.11% and more present in elderly patients, for whom a less invasive treatment can be desirable. Despite innovations in endoscopic equipment and accessories, bleeding and perforation occur in up to 10 and 15% of the cases, respectively. The finding of pharyngeal diverticulum in domestic pigs turned into an experimental model of major interest for training and scientific purposes. For this reason, the introduction of a technical innovation and its comparison with PED conventional treatment were focused. Our aim was to compare the diaeresis of the PED septum by the harmonic scalpel Ultracision ® monopolar electrocautery (Group M) in an experimental model. Twenty domestic pigs (mean weight 20.2 kg; ±1.35) were divided into groups M and U nonrandomly. No significant differences were found related to diverticulum size (p=0.0897) or insertion time of soft diverticuloscope (p=0.7387). In group U, mean time to divide the septum and total procedure time were significantly shorter (p<0.0001) for both comparisons. Regarding incision extension, mean length was significantly higher in group U (p=0.0047). In relation to microscopic parameters, the lateral thermal spread caused by monopolar current (Group M) was found to be more intense (p<0.0001). As for depth and inflammation presence, no differences were verified between the groups. Hemorrhage was exclusively observed in group M (p=0.01) and it was endoscopically managed at all times. When compared to endoscopic incision with needle-knife and monopolar blend current, the experimental endoscopic diverticulostomy using soft diverticuloscope and harmonic scalpel demonstrated to be faster and related to less tissue damage.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
FabioYujiHondo.pdf (1.32 Mbytes)
Fecha de Publicación
2011-08-24
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.