• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2007.tde-13022008-083719
Documento
Autor
Nombre completo
Lucia Camara de Castro Oliveira
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2007
Director
Tribunal
Jorge, Jose Marcio Neves (Presidente)
Capelhuchnik, Peretz
Figueiredo, Luiz Francisco Poli de
Matos, Delcio
Nasi, Ary
Título en portugués
Tratamento da incontinência anal através da injeção transesfincteriana de silicone: correlação entre os resultados clínicos, ultra-sonográficos e de manometria anorretal, incluindo o índice de assimetria esfincteriana
Palabras clave en portugués
Canal anal/ultrasonografia
Incontinência fecal/terapia
Manometria
Qualidade de vida
Silicones/administração & dosagem
Resumen en portugués
Objetivo: Avaliar a segurança e eficácia da injeção transesfincteriana de silicone para o tratamento da incontinência anal, assim como correlacionar os resultados clínicos, ultra-sonográficos e manométricos. Métodos: Pacientes incontinentes foram submetidos à manometria e ultra-sonografia anorretal, índice de incontinência (II) e instrumento de qualidade de vida (FIQL), antes e após injeção do silicone (PTQ) sob anestesia local e profilaxia antibiótica. Os critérios de inclusão foram: incontinência anal, lesão isolada ou múltipla do músculo esfíncter interno do ânus, associada ou não à lesão isolada, em um quadrante, do músculo esfíncter externo do ânus. O instrumento FIQL utilizado inclui quatro domínios: estilo de vida, comportamento,depressão e constrangimento.Os parâmetros da manometria foram: pressão média de repouso (PMR), pressão média (PMCV) e máxima (PmaxCV) de contração voluntária, zona de alta pressão (ZAP) e índice de assimetria (IA). Após três meses de tratamento, os pacientes foram reavaliados através do II, FIQL, manometria e ultra-sonografia anorretal. Um grupo controle composto por 10 homens e 10 mulheres continentes e sem história prévia de cirurgia anorretal foi submetido à manometria após consentimento informado. Resultados: Foram estudados 35 pacientes, 28 mulheres e sete homens com idade média de 60,3 (19-80) anos, antes e após injeção do silicone anal. As complicações observadas incluíram dois hematomas (5,7%), um abscesso anal (2,8%), dor anal em dois pacientes (5,7%) e dificuldade evacuatória em um paciente (2,8%). Notou-se uma melhora do índice médio de incontinência de 11,3 para 4,3 (p < 0,001). Houve melhora de todos os domínios estudados no instumento FIQL (p<0,0001). Pacientes incontinentes apresentaram hipotonia esfincteriana quando comparados aos controles (p < 0,05). As pressões esfincterianas antes e após injeção foram respectivamente: PMR (29,4 mmHg x 35,1 mmHg; p = 0,07), PMCV (68,6 mmHg x 75,9 mmHg; p = 0,20) e PmaxCV (102,2 mmHg x 127,0 mmHg; p = 0,11). Houve aumento médio da ZAP de 1,0 para 1,7 cm (p = 0,002) Em relação aos resultados da manometria: o IA aos 3 e 2 cm apresentou redução significativa após injeção do silicone (p < 0.05 e 0,002). A ultra-sonografia de canal anal demonstrou a presença do silicone nos sítios de injeção em todos os pacientes. Conclusão: Em casos selecionados, a injeção transesfincteriana de silicone é um método seguro e proporciona uma melhora do quadro de incontinência anal, observada pela mudança significativa dos parâmetros de qualidade de vida e índice de incontinência. O provável mecanismo de ação pelo qual o agente estudado melhora o quadro de incontinência parece relacionar-se à correção da assimetria esfincteriana e aumento do comprimento da zona de alta pressão.
Título en inglés
Trans-sphincteric silicone injection for the treatment of anal incontinence: correlation between clinical and physiological evaluation including the asymmetry index
Palabras clave en inglés
Anal canal/ultrasonography
Fecal incontinence/treatment
Manometry
Quality of life
Silicone/administration & dosage
Resumen en inglés
Aim: To evaluate safety and efficacy of trans-sphincteric silicone injection for the treatment of anal incontinence and to assess correlation between clinical and physiological results. Methods: Incontinent patients prospectively selected by clinical and physiological evaluation underwent trans-sphincteric silicone injection (PTQ) under local anesthesia. Eight channel manometry with asymmetry index and anal ultrasound were performed before and after injections. Incontinence scale (IS) and quality of life instrument (FIQL scale) were applied before and after injection.Inclusion criteria were: anal incontinence, isolated or multiple injury of the internal anal sphincter associated or not to small, restricted, external anal sphincter defect. FIQL scale included four domains: life-style, behavior, depression and embarrassment. Manometry evaluation included mean resting pressure (MRP), mean squeeze pressure (MSP), maximal squeeze pressure (MaxSP), high-pressure zone (HPZ) and asymmetry index (AI). After 3 months of treatment the patients had been reevaluated through the IS, FIQL scale, manometry and ultrasound. A controlled group of 20 healthy volunteers (10 men and 10 women) underwent anal manometry. Results: 35 patients (28 women and seven men) with a mean age of 60.3 (19-80) years were evaluated. Complications observed were two anal hematomas (5,7%), one perianal abscess (2.8%), two patients complained of anal pain (5,7%) and one patient required assistance for defecation (2,8%). Mean incontinence score improved significantly after injection: 11, 3 to 4,3 (p < 0.001). Significant improvement in the FIQL scale was noticed in all domains (p < 0.0001). Incontinent patients had significantly lower anal pressures when compared to controls (p < 0.05). Manometric pressures before and after injection did not change: MRP (29,4 mmHg x 35,1 mmHg; p = 0.07), MSP (68,6 mmHg x 75,9 mmHg; p = 0.20) e MaxSP (102.2 mmHg x 127.0 mmHg; p = 0.11) The HPZ changed from 1 to 1,7 cm after injection (p = 0.002) AI at 3 and 2 cm showed a significantly change (p < 0.05 and p = 0.001, respectively). Ultrasound images demonstrated the presence of silicone in all sites of injection. Conclusion: In selected cases, trans-sphincteric silicone injection is an effective treatment for anal incontinence, as significant changes in quality of life and incontinence scales can be observed. The mechanism of action for which the studied agent improves anal incontinence seems to be related to improvement in the asymmetry index as well as a change in the HPZ.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
LuciaCCOliveira.pdf (1.01 Mbytes)
Fecha de Publicación
2008-03-14
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.