Tese de Doutorado
DOI
https://doi.org/10.11606/T.5.2006.tde-16052006-133605
Documento
Autor
Nome completo
Fernando Bliacheriene
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2005
Orientador
Banca examinadora
Auler Junior, Jose Otavio Costa (Presidente)
Carmona, Maria Jose Carvalho
Cruz Junior, Ruy Jorge
Ferez, David
Torres, Marcelo Luis Abramides
Título em português
"Estudo da variação da pressão sistólica e suas componentes como preditoras de hipovolemia em coelhos submetidos à hemorragia e pneumoperitônio"
Palavras-chave em português
Coelhos
Hemorragia
Hipovolemia
Laparoscopia
Monitorização fisiológica
Pneumoperitônio
Pressão arterial
Resumo em português
Objetivos A variação da pressão sistólica (VPS) é parâmetro de avaliação hemodinâmica em indivíduos ventilados mecanicamente. O objetivo deste estudo foi investigá-la em coelhos submetidos à hemorragia e pneumoperitônio. Método Estudou-se 11 coelhas sob 4 tratamentos: após 20 minutos de estabilização (T1); pneumoperitônio de 10mmHg por 30 minutos (T2); hemorragia de 20% da volemia estimada, realizada em 10 minutos, mais 10 minutos de estabilização, na vigência de pneumoperitônio (T3); após reposição do sangue retirado, em 10 minutos, mais 10 minutos de estabilização, sem pneumoperitônio (T4). Resultados Observou-se aumento de VPS significativo (p < 0,05) em T2 e T3, com maior valor em T3, em relação a T1 e que não houve diferença significativa entre T4 e T1. Delta Down tem maior participação na VPS nos tratamentos T1, T3 e T4. Em T2 a contribuição de ambas é equilibrada. Conclusões VPS mostrou ser preditora de hipovolemia durante hemorragia e pneumoperitônio
Título em inglês
Study on systolic pressure variation and its components as predictors of hypovolemia in rabbits submitted to hemorrhage and pneumoperitoneum
Palavras-chave em inglês
Blood pressure
Hemorrhage
Hypovolemia
Laparoscopy
Monitoring physiologic
Pneumoperitoneum
Rabbits
Resumo em inglês
Systolic pressure variation (SPV) is a hemodynamic analysis parameter for mechanically ventilated individuals. The aim of this study was to investigate it in rabbits submitted to hemorrhage and pneumoperitoneum. Methods Eleven rabbits were studied under 4 treatments: after 20 minutes of stabilization (T1); 10 mmHg pneumoperitoneum for 30 minutes (T2); hemorrhage of 20% of the estimated volemia, performed in 10 minutes, followed by 10 minutes of stabilization, under pneumoperitoneum (T3); re-infusion in 10 minutes of the blood shed and more 10 minutes of stabilization, without pneumoperitoneum (T4). Results There was a significant increase in SPV (p < 0.05) in T2 and T3, with a higher value in T3, related to T1 and no difference between T4 and T1. Delta Down is the main component in T1, T3 and T4, while in T2 it is balanced with Delta Up. Conclusions SPV showed to be predictor of hypovolemia during hemorrhage and pneumoperitoneum
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2006-05-19
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.