• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2011.tde-14062011-153309
Document
Auteur
Nom complet
Rodrigo Sanchez Veliz
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2011
Directeur
Jury
Malbouisson, Luiz Marcelo Sá (Président)
Braz, José Reinaldo Cerqueira
Ferez, David
Otsuki, Denise Aya
Torres, Marcelo Luis Abramides
Titre en portugais
Efeitos imediatos da circulação extracorpórea sobre o sistema mucociliar
Mots-clés en portugais
Anestesia cardiotorácica
Circulação extracorpórea
Cirurgia torácica
Depuração mucociliar
Resumé en portugais
INTRODUÇÃO: A circulação extracorpórea (CEC) é um fator etiológico importante para a lesão pulmonar, observada após cirurgia cardíaca. No entanto, o impacto da CEC na função mucociliar respiratória é desconhecido. O objetivo do estudo foi avaliar os efeitos imediatos da CEC sobre o sistema de transporte mucociliar. MÉTODOS: 22 porcos mestiços das raças Large White e Landrace com peso entre 33 a 47 kg alocados nos grupos controle (n = 10) e CEC (n = 12) completaram o estudo. As técnicas de anestesia e ventilação mecânica foram padronizadas. Após a indução da anestesia, foi realizada traqueostomia e uma amostra do tecido traqueal foi excisado (T0) em ambos os grupos. Todos os animais foram submetidos a toracotomia e CEC aorto-bicaval foi instalada no grupo CEC e mantida durante 90 minutos. Após o desmame da CEC (T90), uma segunda amostra do tecido traqueal foi obtida 180 minutos após a traqueostomia (T180). Amostras de muco foram coletadas na traquéia por meio de broncoscopia em T0, T90 e T180. Frequência de batimento ciliar (FBC) e transporte mucociliar in situ (TMC) foram estudados em epitélio traqueal ex vivo. As características do muco respiratório in vitro foram estudadas por transportabilidade ciliar no palato de rã (VTM), Transporte do muco respiratório in vitro pela tosse (TMT), Ângulo de contato (AC) e da viscosidade do muco por viscosímetro Cone-Plate (VM). RESULTADOS: A FBC diminuiu no grupo CEC (13,09 ± 1,91 Hz vs 11,06 ± 2,1 Hz, p <0,05), mas não no grupo controle (13,42 ± 0,96 Hz vs 12, 98 ± 2,84 Hz). No momento T90, a viscosidade aparente avaliado em 100 RPM estava aumentada no grupo CEC em relação ao controle. Não foram observadas diferenças significativas no TMC, VTM, TMT e AC. No grupo de CEC, foi percebida a perda do epitélio ciliado, edema submucoso e infiltração de células inflamatórias na avaliação histológica da traqueia. CONCLUSÃO: A CEC compromete agudamente o sistema de transporte mucociliar traqueal. Novos estudos são necessários para avaliar se esse comportamento tem implicações clínicas
Titre en anglais
Immediate effects of cardiopulmonary bypass on mucociliary system
Mots-clés en anglais
Cardiopulmonary bypass
Cardiothoracic anesthesia
Mucociliary clearance
Thoracic surgery
Resumé en anglais
BACKGROUND: Cardiopulmonary bypass (CPB) is an important etiologic factor for lung injury observed after cardiac surgery. However, the impact of CPB on respiratory mucociliary function is unknown. The objective of this study was to assess the immediate effects of CPB on mucociliary transport system. METHODS: Twenty-two mixed breed of Large White and Landrace pigs with weight between 33 to 47kg assigned to control (n=10) and CPB groups (n=12) completed the study. The techniques of anesthesia and mechanical ventilation were standardized. After anesthesia induction, tracheotomy was performed and a tracheal tissue sample was excised (T0) in both groups. All animals underwent thoracotomy and aorto-bicaval CPB was installed in CPB group and maintained during 90 minutes. After weaning from CPB (T90), a second tracheal tissue sample was obtained 180 minutes after tracheotomy (T180). Mucus samples were collected from the trachea using a bronchoscope at T0, T90 and T180. Ciliary beat frequency (CBF) and in situ mucociliary transport (MCT) were studied in ex vivo tracheal epithelium. In vitro respiratory mucus characteristics were studied by mucociliary transportability in frog palate (MT), Cough clearance (CC), Contact angle (CA) and the mucus viscosity by Cone-Plate viscometer (MV). RESULTS: CBF decreased in CPB group (13.09 ± 1.91 Hz vs. 11.06 ± 2.1 Hz, p < 0.05) but not in control group (13.42 ± 0.96 Hz vs. 12.98 ± 2.84 Hz). At T90 Apparent viscosity evaluated at 100 RPM increased in CPB group compared to control. No significant differences were observed in MCT, MT, CA and CC. In CPB group, it was observed loss of ciliated epithelia, submucosal edema and inflammatory cells infiltration in tracheal histology. CONCLUSION: CPB acutely compromise the tracheal mucociliary transport system. New studies are necessary to investigate if this behavior has any clinical implication
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2011-06-20
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.