• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.5.2009.tde-04032010-181326
Document
Author
Full name
Marcel Rezende Lopes
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2009
Supervisor
Committee
Auler Junior, Jose Otavio Costa (President)
Carmona, Maria Jose Carvalho
Garrido, Alejandra Del Pilar Gallardo
Machado, Flavia Ribeiro
Otsuki, Denise Aya
Title in Portuguese
Desenvolvimento e validação de algoritmo para mensuração contínua e ou intermitente das variações da pressão arterial em monitor multiparamétrico: estudo piloto em pacientes de alto risco cirúrgico
Keywords in Portuguese
Algoritmos
Complicações pós-operatórias
Pressão arterial
Respiração artificial
Volume sistólico
Abstract in Portuguese
Introdução: Diversos estudos mostraram que maximizar (ou aumentar até se alcançar um platô) o volume sistólico com infusão de fluidos durante uma cirurgia de alto risco pode melhorar o resultado pós-operatório. Este objetivo pode ser atingido simplesmente minimizando-se a variação da pressão arterial (PP) induzida por ventilação mecânica. Testou-se esta hipótese em um único e potencial centro de estudo aleatório. O objetivo principal foi a análise da duração de permanência hospitalar pós-operatória. Métodos: Trinta e três pacientes submetidos a cirurgias de alto risco foram randomizados em grupo controle (Grupo C, n = 16) e grupo intervenção (Grupo I, n = 17). No grupo I, o PP foi continuamente monitorizado durante a cirurgia por um dispositivo automático (DX 2020, Dixtal, São Paulo, Brasil) e minimizado até 10% da variação com infusão adicional de fluidos. Resultados: No período pré-operatório, os Grupos C e I foram comparados com base nos dados demográficos, classificação da American Society of Anesthesiologists (classificação ASA) - Sociedade Americana de Anestesiologistas, tipo e duração da cirurgia. Durante a cirurgia, o Grupo I recebeu mais fluido que o Grupo C (4618 ± 1557 vs 1694 ± 705 ml, p<0,0001), e o PP diminuiu de 22 ± 7 para 9 ± 1% (p < 0,05) no Grupo I. A duração média da permanência hospitalar pós-operatória (7 vs 17 dias, p<0,01) foi menor no Grupo I que no Grupo C. O número de complicações pós-operatória por paciente (1,4 ± 2,1 vs 3,9 ± 2,8, p<0,05), bem como a duração média da ventilação mecânica (1 vs 5 dias, p<0,05) e estadia na Unidade de Terapia Intensiva (UTI) (3 vs 9 dias, p<0,01) também foram mais baixas no Grupo I. Conclusão: Monitorar e minimizar a variação do PP com infusão de fluidos durante cirurgias de alto risco melhorou o resultado pós-operatório e diminuiu a duração da permanência hospitalar. Registro do Estudo: NCT00479011
Title in English
Development and validation of an algorithm for continuously and intermittent measurement of arterial pressure in a multiparametric monitor: pilot study in high risk surgical patients
Keywords in English
Algorithms
Artificial respiration
Blood pressure
Postoperative complications
Stroke volume
Abstract in English
Background: Several studies have shown that maximizing (or increasing until reaching a plateau) stroke volume by volume loading during high-risk surgery may improve postoperative outcome. This goal could be achieved simply by minimizing arterial pulse pressure variation (PP) induced by mechanical ventilation. We tested this hypothesis in a prospective, randomised, single centre study. The primary endpoint was the length of postoperative hospital stay. Methods: Thirty-three patients undergoing high-risk surgery were randomized either to a control group (group C, n = 16) or to an intervention group (group I, n = 17). In group I, PP was continuously monitored during surgery by an automatic device (DX 2020, Dixtal, and Sao Paulo, Brazil) and minimized to 10% by volume loading. Results: Pre-operatively, group C and group I were comparable in terms of demographic data, ASA score, type, and duration of surgery. During surgery, group I received more fluid than group C (4618 ± 1557 vs 1694 ± 705 ml, p<0.0001), and PP decreased from 22 ± 7 to 9 ± 1% (p < 0.05) in group I. The median duration of postoperative hospital stay (7 vs 17 days, p<0.01) was lower in group I than in group C. The number of post-operative complications per patient (1.4 ± 2.1 vs 3.9 ± 2.8, p<0.05), as well as the median duration of mechanical ventilation (1 vs 5 days, p<0.05) and ICU stay (3 vs 9 days, p<0.01) was also lower in group I. Conclusion: Monitoring and minimizing PP by volume loading during high-risk surgery improves post-operative outcome and decreases length of hospital. Trial registration: NCT00479011
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2010-03-15
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.