Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2010.tde-24112010-181156
Document
Auteur
Nom complet
Carlos Augusto Ventura Pinto
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2010
Directeur
Jury
Chammas, Maria Cristina (Président)
Amaro Júnior, Edson
Kodaira, Sergio Keidi
Macedo, Tulio Augusto Alves
Shigueoka, David Carlos
Titre en portugais
Contraste por microbolhas em ultrassonografia no diagnóstico diferencial entre oclusão e pseudo-oclusão da artéria carótida interna: correlação com a  angiotomografia
Mots-clés en portugais
Artéria carótida interna
Estenose das carótidas
Microbolhas
Tomografia
Ultrassonografia
Resumé en portugais
Objetivo: Avaliar a eficácia da ultrassonografia com contraste (US com contraste) de segunda geração no diagnóstico diferencial entre oclusão e pseudo-oclusão de artéria carótida interna cervical (ACI) comparativamente à ultrassonografia com Doppler (US Doppler) utilizando a angiotomografia computadorizada (angio-TC) como padrão-ouro. Materiais e Métodos: Estudo prospectivo realizado entre junho de 2006 e junho de 2008 com 72 pacientes sintomáticos (57; 15) e 78 com ACIs aparentemente ocluídas pela US Doppler. Esses pacientes foram submetidos inicialmente à US Doppler e, em seguida, à US com contraste. Todos os pacientes realizaram posteriormente a angio-TC, utilizada como padrão-ouro. A correlação entre os métodos foi feita através de estudo duplo cego. Resultados: A sensibilidade, a especificidade e a acurácia da US com contraste foram respectivamente de 100%; 90,5% e 97,4%. Quando comparada à angio-TC, a quantidade de falsas oclusões pela US Doppler foi de 26,9% (21/78), (p < 0,001), enquanto que pela US com contraste foi de 2,6% (2/78) (p = 0,500). A US com contraste obteve melhor resultado que a US Doppler, com diferença estatisticamente significante (p < 0,001). Conclusão: A US com contraste é tão eficaz quanto a angio-TC e superior à US Doppler no diagnóstico diferencial entre oclusão e pseudo-oclusão da ACI
Titre en anglais
Ultrasound microbubble contrast for distinguishing the diagnosis of cervical internal carotid artery occlusion from the one of pseudo-occlusion utilizing computerized angiotomography as the gold standard
Mots-clés en anglais
Carotid stenosis
Internal carotid artery
Microbubbles
Tomography
Ultrasound
Resumé en anglais
Purpose: Evaluate the efficacy of second-generation contrast ultrasound (CEUS) for distinguishing the diagnosis of cervical internal carotid artery (ICA) occlusion from the one of pseudo-occlusion when compared with Doppler Ultrasound (DUS) utilizing computerized angiotomography (CTA) as the gold standard. Material and Methods: A prospective study was performed between June 2006 and June 2008 with 72 symptomatic patients (57 males; 15 females) and 78 ICAs apparently occluded by DUS. These patients were initially subjected to DUS and then to CEUS. All patients went through CTA later on, used as the gold standard. Correlation between the methods was made by means of a double-blind study. Results: The sensitivity, specificity and accuracy of CEUS were taken as 100%, 90.5% and 97.4% respectively. When compared with CTA the amount of false occlusions by DUS was 26.9% (21/78), (p < 0.001) whereas by CEUS 2.6% (2/78) (p = 0.500) was seen. Far better results were obtained with CEUS than with DUS with a significant discrepancy (p < 0.001). Conclusion: CEUS shows to be as effective as CTA but better than DUS for distinguishing the diagnosis of ICA occlusion from the one of pseudo-occlusion
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2010-11-26
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.