• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2004.tde-13102005-165153
Documento
Autor
Nombre completo
Breno Barth Amaral de Andrade
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2004
Director
Tribunal
Jose, Newton Kara (Presidente)
Abib, Fernando Cesar
Alves, Milton Ruiz
Netto, Adamo Lui
Nose, Walton
Título en portugués
"Desempenho visual na correção de miopia com óculos e lentes de contato gelatinosas"
Palabras clave en portugués
ACUIDADE VISUAL
ESTUDOS PROSPECTIVOS
LENTES DE CONTATO/estatística & dados numéricos
MIOPIA/terapia
ÓCULOS/utilização
SENSIBILIDADES DE CONTRASTE
Resumen en portugués
Objetivos: Avaliar o desempenho visual(DV), por meio da AV logMAR de alto contraste, sensibilidade ao contaste(SC) e análise de frentes de onda(AFO), em míopes, com óculos e três LCG. Métodos: Estudo clínico e prospectivo, em 40 indivíduos míopes(-1,00D e -4,50D). Exames: AV logMAR de alto contraste, avaliação de SC e AFO. Resultados: A AFO detectou diferença na aberração de terceira ordem sem e com as LCG.. Em relação ao nível trifoil houve diferença entre com e sem LCG. Conclusões: Na avaliação do DV com óculos e com LCG, a AFO é uma medida mais sensível da função visual que a AV LogMAR de alto contraste e a SC.
Título en inglés
Visual performance in myopic correction with spectacles and soft contact lenses
Palabras clave en inglés
CONTACT LENSES/statistics & numerical data
CONTRAST SENSITIVITY
EYEGLASSES/Utilization
MYOPIA/therapy
PROSPECTIVE STUDIES
VISUAL ACUITY
Resumen en inglés
Objective: to evaluate the visual performance(VP) by Visual acuity(VA)Logmar of high contrast, sensibility of contrast(SC) and wavefront (WF) in myopic patients correct with spectacles and 3 SCL Methods: prospective clinical trial was performed in 40 myopic patients(-1,00 D and -4,50 D). Exams: VA, WF and CS. Results: The WF analysis detected a significant difference in a third order aberration with and without SCL. There was significant difference related to trefoil coefficient in VP between with and without SCL. Conclusion: In VP evaluation with spectacles and SCL the wavefront analysis was more sensible measure of VP when compared with high contrast VA Logmar and CS.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
brenobarthandrade.pdf (1.02 Mbytes)
Fecha de Publicación
2005-10-18
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.