• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2007.tde-10032008-153020
Documento
Autor
Nombre completo
David Tayah
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2007
Director
Tribunal
Alves, Milton Ruiz (Presidente)
Betinjane, Alberto Jorge
Lui Netto, Adamo
Matayoshi, Suzana
Rehder, Jose Ricardo Carvalho Lima
Título en portugués
Componentes oculares em anisometropia
Palabras clave en portugués
Anisometropia
Biometria/Métodos
Erros de refração.
Olho/crescimento & desenvolvimento
Olho/Ultra-sonografia
Resumen en portugués
Objetivo: Em anisométropes, comparar os valores médios individuais dos componentes oculares de ambos os olhos (poder da córnea, profundidade da câmara anterior, poder equivalente do cristalino e comprimento axial), correlacionar as diferenças dos componentes oculares com as diferenças de refração de ambos os olhos; verificar a contribuição total e a seqüência geral de influência das variáveis na diferença refrativa; e identificar o menor número de fatores que contenham o mesmo grau de informações expressas no conjunto de variáveis que influenciam na diferença refrativa. Métodos: Realizou-se um estudo transversal analítico em população de 77 anisométropes de duas ou mais dioptrias, atendida no ambulatório de Oftalmologia do Hospital Universitário da Faculdade de Medicina Nilton Lins, Manaus, Amazonas. Os anisométropes foram submetidos à refração estática objetiva e subjetiva, ceratometria e biometria ultra-sônica A-scan. A análise dos dados foi feita por meio dos seguintes modelos estatísticos: análise univariada, multivariada, de regressão múltipla e fatorial. Resultados: Não houve diferenças significativas na comparação dos valores médios individuais dos componentes oculares entre os olhos. Houve correlação negativa média entre a diferença refrativa e a diferença de comprimento axial (r=-0,64) (P<0,01) e correlação negativa fraca entre a diferença refrativa e a diferença de poder do cristalino (r=-0,34) (p<0,01). As variáveis analisadas responderam, no seu conjunto, por 78% da variação total para a diferença refrativa. A seqüência geral de influência das variáveis na diferença refrativa foi a seguinte: comprimento axial, poder do cristalino, poder da córnea e profundidade da câmara anterior. Foram identificados três fatores para a diferença refrativa: a) fator 1 (refração, comprimento axial); b) fator 2 (profundidade da câmera anterior, poder da córnea) e c) fator 3 (poder do cristalino). Conclusões: O estudo conduzido em 77 indivíduos com anisometropias variando de 2,00 a mais de 19,00 dioptrias, realizado para avaliar a influência dos componentes oculares, mostrou que o comprimento axial foi o principal fator causador das anisometropias, seguido pelo cristalino que contribuiu menos, depois pela córnea e profundidade da câmara anterior, com contribuições ainda menores. A investigação sugere falência no mecanismo adaptativo normal em anisometropia, o que poderia produzir não só descontrole do alongamento do comprimento axial (fator 1), mas também falência no controle do aplanamento da córnea e do aprofundamento da câmara anterior (fator 2) e no achatamento do cristalino (fator 3).
Título en inglés
The ocular components in anisometropia
Palabras clave en inglés
Anisometropia
Biometry/methods
Eye/growth & development
Eye/ultrasound
Refractive errors.
Resumen en inglés
Purpose: To compare the individual means of ocular components of both eyes (corneal power, anterior chamber depth, crystalline lens power and axial length) in patients with anisometropia; to correlate the differences of the ocular components with refractive differences in both eyes; to verify total contribution and the sequence of influence that variables have in refractive differences, and to identify the smallest number of factors that contain the same level of information expressed in the set of variables that influence refractive difference. Methods: An analytical transversal study was carried out in 77 patients with anisometropia of two or more dioptres seen at the Ophthalmologic Clinic, University Hospital, Medical School Nilton Lins, Manaus, Amazon state. All participants were submitted to ophthalmologic exam which included objective and subjective cycloplegic refractometry, keratometry and ultrasonic biometry. Data analysis comprised the following statistical models: univariate, multivariate, multiple and factorial regression analyses. Results: There were no significant differences in the comparison of the individual means of the ocular components. There was negative correlation between refractive difference and difference of axial length (r=- 0.64; p<0.01) and weak negative correlation between refractive difference and crystalline lens power difference (r=-0.34; p< 0.01). The analyzed variables amounted to 78% of the total variation of refractive difference. The general sequence of variables influencing refractive difference was: axial length, crystalline lens power, cornea power, and anterior chamber depth. There were three factors identified for refractive differences: a) factor 1 (refraction, axial length); b) factor 2 (anterior chamber depth, cornea power), and c) factor 3 (crystalline lens power). Conclusions: Seventy-seven cases of anisometropia ranging from 2,00 to over 19,00 dioptres, examined for the individual components of refraction, showed that axial length was the major causative factor; crystalline lens have contributed less, followed by cornea and anterior chamber length. This study has suggested deficit of the normal adaptive mechanism in anisometropia that could produce not only axial elongation (factor 1), but also failure to control flattening of the cornea, deepening of the anterior chamber length (factor 2) and flattening of crystalline lens (factor 3).
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
DavidTayah.pdf (2.64 Mbytes)
Fecha de Publicación
2008-03-18
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.