Master's Dissertation
DOI
https://doi.org/10.11606/D.5.2013.tde-09082013-115635
Document
Author
Full name
Paola da Ponte Silva
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2013
Supervisor
Committee
Abensur, Hugo (President)
Canziani, Maria Eugenia Fernandes
Seguro, Antonio Carlos
Title in Portuguese
Avaliação da extração e cinética de solutos em pacientes submetidos à hemodiálise convencional, hemodiafiltração pós-diluição e hemofiltração pré-diluição
Keywords in Portuguese
Falência renal crônica
Hemodiafiltração
Hemodiálise
Hemofiltração
Abstract in Portuguese
Introdução: O uso de membranas de alto fluxo tornou-se comum na prática de hemodiálise convencional (HDC), hemodiafiltração (HDF) e hemofiltração (HF) devido ao elevado coeficiente de ultrafiltração e à maior permeabilidade do poro. A produção de fluido de reposição online proporciona maior facilidade na execução de HDF e HF. Estas modalidades aumentam a depuração de solutos maiores por convecção. O objetivo do estudo é comparar a eficácia de três métodos dialíticos: HDC, HDF online (HDF-OL) pós-diluição e HF online (HF-OL) pré-diluição, por meio da quantificação direta da dose de diálise pela extração de solutos. Método: Trata-se de um ensaio clínico, envolvendo 14 pacientes em hemodiálise. Os pacientes iniciaram no estudo na modalidade de HDC com prescrição de quatro horas, fluxo de sangue de 350ml/min e fluxo de dialisato de 800ml/min com dialisador novo de alto fluxo e alta eficiência. Posteriormente, os mesmos pacientes foram submetidos à uma sessão de HDF-OL pós-diluição de quatro horas, fluxo de sangue de 350ml/min, fluxo de reposição de 100ml/min e fluxo de dialisato de 700ml/min. Por último, fizeram uma sessão de HF-OL pré-diluição com mesma duração, fluxo de sangue de 350ml/min e fluxo de reposição de 100% do fluxo de sangue. Foram realizadas 42 sessões de tratamento. A extração de solutos foi avaliada por meio de dosagens plasmáticas e quantificação do efluente. Resultados: As concentrações séricas dos solutos pré-diálise não foram diferentes entre as sessões do estudo. O volume de substituição em HDF-OL foi de 20,6 ± 0,8L/sessão e em HF-OL foi de 81,8 ± 7,1L/sessão. A HDF-OL quando comparada com a HDC não apresentou diferença na extração de moléculas pequenas. Da mesma forma, a extração de ?2-microglobulina foi semelhante nas 3 modalidades: 121,1 ± 46,4 mg em HDC, 130,1 ± 46,5 mg em HDF-OL e 106,0 ± 45,0 mg em HF-OL. A perda de albumina foi significativamente maior em HDF-OL (1360,2 ± 425,0 mg) e HF-OL (1310,3 ± 201,4 mg) Vs. HDC (269,6 ± 15,3 mg) (p<0,0001). A depuração de pequenos solutos foi superior em HDF-OL. A depuração de ?2-microglobulina foi maior em HDF- OL (114,0 ± 15,7 ml/min) e HF-OL (116,1 ± 19,5 ml/min) Vs. HDC (86,5 ± 16,1 ml/min) (p<0,0001). A dose de diálise avaliada pelo singlepool, equilibrated, standard Kt/V e pela quantificação direta da diálise (DDQKt/V) não foi diferente entre HDF-OL e HDC. Na HF-OL a ausência de difusão contribuiu para menor extração e menor Kt/V de solutos pequenos (p<0,0001). Conclusão: A dose de diálise avaliada pela extração de solutos foi semelhante entre HDC e HDF-OL sendo a HF-OL menos favorável na extração de solutos pequenos
Title in English
Solutes extraction and kinects assessment in patients submitted to a conventional hemodialysis, postdilution hemodiafiltration and predilution hemofiltration
Keywords in English
Chronic kidney failure
Hemodiafiltration
Hemodialysis
Hemofiltration
Abstract in English
Introduction: The use of high-flux membranes became common practice in conventional hemodialysis (CHD), hemodiafiltration (HDF) and hemofiltration (HF) due to the high pore permeability and ultrafiltration coefficient. The online production of substitution volume can make easier HDF and HF execution. These modalities can increase the clearance of larger solutes by convection. The aim of this study is to compare the dialysis efficacy among three methods: CHD, online post-dilution HDF (OL-HDF), and online pre- dilution HF (OL-HF) through the direct quantification of dialysis dose by the solutes extraction. Method: This is a clinical trial involving 14 patients on hemodialysis. The patients began the study in CHD modality with a four-hour prescription, blood flow of 350ml/min and dialysate flow of 800ml/min with new high-flux and high efficiency dialyzer. Subsequently, these patients were submitted to a four-hour post-dilution OL-HDF session, with flow replacement of 100ml/min, blood flow of 350ml/min and dialysate flow of 700ml/min. Finally, patients underwent a pre-dilution OL-HF with the same duration, blood flow of 350ml/min and flow replacement of 100% of the blood flow. Forty-two sessions of treatments were performed. The solutes extraction was assessed by plasma measurements and effluent quantification Results: Pre-treatment serum concentrations of different solutes showed no statistical difference among the modalities. The substitution volume in OL- HDF was 20.6 ± 0.8L/session and in OL-HF was 81.8 ± 7.1 L/session. The OL-HDF compared to CHD showed no difference in the small solutes extraction. Similarly, ?2-microglobulin extraction was similar among the three modalities: 121.1 ± 46.4 mg in CHD, 130.1 ± 46.5 mg in OL-HDF and 106.0 ± 45.0 mg in OL-HF. Albumin loss was significantly higher in OL-HDF (1360.2 ± 425.0 mg) and OL-HF (1310.3 ± 201.4 mg) Vs. CHD (269.6 ± 15.3 mg) (p<0.0001). The small solutes clearance was greater in OL-HDF. ?2- microglobulin clearance was higher in OL-HDF (114.0 ± 15.7 ml/min) and OL- HF (116.1 ± 19.5 ml/min) Vs. CHD (86.5 ± 16.1 ml/min) (p<0.0001). The dialysis dose measured by singlepool, equilibrated, standard Kt/V and by direct dialysis quantification (DDQ Kt/V) was not different between CHD and OL-HDF. In OL-HF the absence of diffusion contributed to lower extraction and lower Kt/V of small solutes. Conclusion: The dialysis dose evaluated by extraction of solutes was similar between CHD and OL-HDF being a OL-HF less favorable in small solutes extraction
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
PaoladaPonteSilva.pdf (1.43 Mbytes)
Publishing Date
2013-08-09
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.