• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.5.2014.tde-09062014-101133
Document
Author
Full name
Carla Barbosa Muraro Furlan
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2014
Supervisor
Committee
Abensur, Hugo (President)
Canziani, Maria Eugenia Fernandes
Elias, Rosilene Motta
Miorin, Luiz Antonio
Moyses, Rosa Maria Affonso
Title in Portuguese
O impacto de reúso de dialisadores nos marcadores de estresse oxidativo e inflamatórios em pacientes em hemodiálise
Keywords in Portuguese
Acetilcisteína/uso terapêutico
Ácido peracético
Diálise renal
Estresse oxidativo
Inflamação
Reutilização de equipamento
Substâncias reativas com ácido tiobarbitúrico
Abstract in Portuguese
A morbimortalidade dos pacientes em hemodiálise permanece alta apesar da evolução tecnológica do procedimento, sendo que os eventos cardiovasculares são a sua principal causa. Estes desencadeados pela alta prevalência de fatores de risco tradicionais, fatores relacionados ao procedimento dialítico e estresse oxidativo. Considerando o procedimento dialítico e o estresse oxidativo, foi avaliado o quanto a habitual prática de reuso de dialisadores/RD (difundida nas Américas e amparada principalmente por questões econômicas) e uso único de dialisadores, influenciam nos marcadores inflamatórios e de estresse oxidativo. Para isto, foram utilizados como marcadores laboratoriais as medidas de PCR ultrassensível (u PCR), interleucina 6 (IL6), a determinação de substâncias reativas ao ácido tiobarbitúrico (TBARS), superóxido dismutase (SOD), glutationa (GSH) e albumina, em 29 pacientes em tratamento de hemodiálise. Estes pacientes encontravam-se em tratamento com dialisadores de alto fluxo do tipo polieterssulfona e reuso manual, e ao iniciar este estudo foram programados 3 ciclos sequenciais com duração de 6 semanas com as seguintes características: primeiro ciclo (uso único de dialisadores;); segundo ciclo (reuso de dialisadores); terceiro ciclo (reuso de dialisadores e administração de N-acetilcisteína/NAC, na dose de 1200 mg/dia). Foram coletadas amostras de sangue de cada paciente no início e final da última sessão de hemodiálise anteriormente ao início dos ciclos (denominado Período 1) e no início e final da última sessão de hemodiálise de cada ciclo (denominados Períodos 2, 3 e 4 respectivamente). O TBARS aumentou no período de uso único. Todas as demais variáveis não apresentaram diferença significativa. Os resultados indicaram que o RD pode proporcionar uma melhora no estresse oxidativo. O uso único foi associado com maior estresse oxidativo. Não foi encontrado nenhum benefício adicional com NAC
Title in English
Evaluation of oxidative stress and inflamatory markers on hemodialysis patients with and without dialysers reuse
Keywords in English
Acetylcysteine/therapeutic use
Equipment reuse
Inflammation
Oxidative stress
Peracetic acid
Renal dialysis
Thiobarbituric acid reactive substances
Abstract in English
The morbidity and mortality of patients undergoing hemodialysis remains high despite the technological development of this procedure, and cardiovascular events are the main causes of morbidity and mortality. These cardiovascular events are triggered by the high prevalence of traditional risk factors, factors associated with dialysis procedures, and oxidative stress. Considering the factors associated with dialysis procedures and oxidative stress, we assessed how dialyzer reuse (DR; widespread in the Americas, especially because of economic issues) and use of single-use dialyzers influence oxidative stress and inflammatory markers. We used ultrasensitive PCR (u-PCR) to measure levels of the laboratory markers interleukin-6 (IL6), thiobarbituric acid reactive substances (TBARS), superoxide dismutase (SOD), glutathione (GSH), and albumin in 29 patients undergoing hemodialysis treatment. These patients were receiving treatment with polyethersulfone high-flux dialyzers and manual reuse. In the initial phase of this study, the 3 following sequential cycles, each lasting 6 weeks, were scheduled: first cycle (single-use dialyzers); second cycle (DR); and third cycle (DR and administration of N-acetylcysteine [NAC] at a dose of 1200 mg/day). Blood samples were collected from each patient at the beginning and end of the last hemodialysis session that preceded the start of the cycles (termed Period 1), and at the beginning and end of the last hemodialysis session of each cycle (termed Periods 2, 3, and 4, respectively). The levels of TBARS increased during the single-use period. The remaining variables did not show significant differences. The results indicated that DR may ameliorate oxidative stress. Single-use dialyzers were associated with higher oxidative stress. No additional benefit was found with use of NAC
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2014-06-09
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.