• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2008.tde-04042008-152959
Document
Auteur
Nom complet
Flávia Silva Reis Medeiros
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2008
Directeur
Jury
David Neto, Elias (Président)
Abensur, Hugo
Pestana, Jose Osmar Medina de Abreu
Silva Filho, Álvaro Pacheco e
Vieira Junior, José Mauro
Titre en portugais
Avaliação da dosagem sérica de cistatina C para detecção precoce de alterações na função do enxerto após o transplante renal
Mots-clés en portugais
Cistatinas
Inulina
Taxa de filtração glomerular
Transplante de rim
Resumé en portugais
INTRODUÇÃO: A cistatina C é uma proteína não glicosilada de baixo peso molecular que é produzida por todas as células nucleadas. A medida da concentração sérica (CS) de cistatina C tem sido aclamada como um marcador de função renal superior à medida da CS de creatinina. No presente estudo, avaliou-se a acurácia diagnóstica da proteína cistatina C em estimar mudanças no Ritmo de Filtração Glomerular (RFG) medido por 51Cr-EDTA, em análise longitudinal prospectiva de pacientes transplantados renais com tempo de transplante recente e tardio. Em uma fase inicial (Fase A), definimos a melhor estratégia metodológica para a realização do RFG por depuração plasmática de 51Cr-EDTA em receptores de enxerto renal utilizando a depuração renal de inulina como método padrão-ouro. MÉTODOS: Medidas simultâneas de depuração renal de inulina e de depuração plasmática de 51Cr-EDTA foram feitas em pacientes transplantados renais. A precisão do método de medida do RFG por 51Cr-EDTA foi avaliada em doadores após um ano de doação de rim. A análise de Bland&Altman foi empregada para avaliar a concordância entre os métodos. Em uma segunda fase, foram realizadas medidas das CS de cistatina C e de creatinina e do RFG por 51Cr-EDTA nos meses 1, 3, 6 e 12 de seguimento clínico do estudo em pacientes transplantados renais. A cistatina C foi dosada em amostras de soro, por técnica de imunonefelometria (N Latex Cystatin C kit - Dade Behring). A tendência da função renal foi obtida por Regressão Linear Simples. RESULTADOS: Na fase A, foram incluídos 44 pacientes transplantados renais e 22 doadores de rim com tempo de doação de 12,4 a 53,5 meses. A depuração de 51Cr-EDTA com amostras de sangue coletadas nos tempos 2, 4, 6 e 8 horas após injeção do radiofármaco apresentou forte correlação e alto grau de concordância com a depuração de inulina; uma estratégia única para todos os níveis de função foi estabelecida com amostras de sangue nos tempos 4 e 6 horas. Em uma segunda fase do estudo, oitenta e dois pacientes foram incluídos, com idade média de 43,4 ± 11,9 anos. A maioria era da raça branca (56%) e do sexo masculino (68%). No mês 1, a média do RFG por 51Cr-EDTA foi de 50,6 ± 17,3 ml/min/1,73m², e foi de 1,62 ± 0,65 mg/L para a CS de cistatina C e de 1,40 ± 0,62 mg/dL para a CS de creatinina. Na análise transversal, foi encontrada uma forte correlação entre o RFG e a medida de CS de cistatina C. Entretanto, na análise longitudinal do seguimento clínico a CS de cistatina C não estimou a tendência de mudança no RFG. CONCLUSÕES: A depuração plasmática de 51Cr-EDTA é uma medida precisa e acurada de RFG que pode ser utilizada em substituição à depuração renal de inulina, em pacientes transplantados renais. Medidas seriadas da CS de cistatina C não foram capazes de detectar mudanças no RFG em pacientes transplantados renais.
Titre en anglais
Evaluation of the serum concentration of cystatin C to early detection changes in graft function after kidney transplantation
Mots-clés en anglais
Cystatins
Glomerular filtration rate
Inulin
Kidney transplantation
Resumé en anglais
INTRODUCTION: Cystatin C is a nonglycosylated protein that is synthesized by all nucleated cells. The present study aimed to analyze the accuracy of serum concentration of cystatin C for detecting longitudinal change in glomerular filtration rate in transplanted recipients, as well to define a better methodological strategy to perform the plasma clearance of 51Cr-EDTA in renal transplant patients using inulin clearance as the gold standard method. METHODS: in the first phase of the study, simultaneous measurements of plasma clearance of 51Cr-EDTA and renal clearance of inulin in stable renal transplanted patients were performed. The within-subject repeatability of the 51Cr-EDTA was evaluated in live kidney donors at least 12 months after donation. Bland&Altman statistical approach was used to quantify the degree of agreement between clearance of inulin and plasma clearance of 51Cr-EDTA. In a second phase, serial measures of plasma clearance of 51Cr-EDTA, serum cystatin C and serum creatinine were examined in folowing at 1, 3, 6 and 12 months in kidney transplanted patients. Serum cystatin C was measured by a nephelometric immunoassay (N latex cystatin C kit - Dade Behring). The trend in renal function over time was obtained by linear regression. RESULTS: In the first phase, 44 transplanted patients and 22 kidney donors at least 12 months after donation (range 12,4 to 53,5 months) were enrolled. Plasma clearance of 51Cr-EDTA with four samples taken at 2, 4, 6 and 8 hours presented a strong association and closely agreement with inulin clearance. An abbreviated strategy was recommended with two blood sampling collected at 4 and 6 hours. In the second phase, 82 kidney transplanted patients were enrolled. Mean age was 43.4 ± 11.9 years. The majority were white (56%) and male (68%). The mean of the plasma clearance of 51Cr-EDTA was 50.6 ± 17.3, and it was 1.62 ± 0.65 mg/L and 1.40 ± 0.62 mg/dL for serum cystatin C and creatinine, respectively, at baseline. In cross-section analysis, serum cystatin C was strongly correlated with plasma clearance of 51Cr-EDTA. However, in longitudinal analysis serum cystatin C was not able for estimate GFR. CONCLUSIONS: Plasma clearance of 51Cr-EDTA is a precise method to measure GFR in renal transplanted recipients. The results showed that serial measurements of serum cystatin C are not able to detect trends in renal function in transplanted patients.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
FlaviaSRMedeiros.pdf (615.03 Kbytes)
Date de Publication
2008-04-07
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.