• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2009.tde-25062009-095303
Document
Auteur
Nom complet
Magali Gaspar Lourenço
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2009
Directeur
Jury
Pasqualucci, Carlos Augusto Goncalves (Président)
Cabral, Richard Halti
Silva, Zenon
Souza, Nair Trevizan Machado de
Souza, Wilson Machado de
Titre en portugais
Análise da morfologia e da vascularização do aparelho valvar das valvas mitral e tricúspide do homem: analogia com o coração canino
Mots-clés en portugais
Artérias
Cães
Coração
Estudo comparativo
Homens
Morfologia
Músculos papilares
Valva mitral
Valva tricúspide
Veias
Resumé en portugais
Objetivou-se, neste trabalho, estudar a morfologia e vascularização do aparelho valvar das valvas mitral e tricúspide em corações humanos, comparando os resultados com aqueles obtidos em cães. A estereologia foi usada como ferramenta que permitiu avaliar os volumes entre as cúspides valvares, cordas tendíneas e mm. papilares, para o conhecimento das relações anatômicas desta estrutura. Foram analisados 15 corações humanos (10 homens e cinco mulheres, com idades variando de 9 a 77 anos) e 15 corações caninos (Canis familiaris - SRD 10 machos e cinco fêmeas, adultos). Os corações, sem alterações macroscópicas, foram dissecados, pesados e seu volume aferido com vistas a análise da morfologia. O estudo da irrigação e drenagem foi realizado por meio de moldes vasculares, em 10 corações de cada espécime. Fundamentados nos resultados obtidos, concluiu-se que as estruturas do aparelho valvar do coração canino e humano apresentam semelhanças tanto morfológicas como em relação a vascularização.
Titre en anglais
Morphology and vascularization of the human valvar apparatus of the mitral and tricuspid valves: analogy with canine heart
Mots-clés en anglais
Arteries
Comparative study
Dogs
Heart
Man
Mitral valve
Morphology
Papillary muscles
Tricuspid valve
Veins
Resumé en anglais
In this study we performed a comparative analysis of the morphology and vascularization of the valvar apparatus of the mitral and tricuspid valve of the human and canine heart. The volumes of the heart and valvar structures (valvar cuspids, chordae tendineae and papillary muscle) were investigated using stereological method. Fifteen human (10 men and 5 women) and 15 canine (mongrel dogs, 10 males and 5 females) hearts of different ages were studied. Ten hearts of each specimen were perfused with vascular cast material to assess and describe the vascularization. Our findings indicate that human and canine valvar apparatus of the mitral and tricuspid valves and its vascularization are similar.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2009-06-30
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.