• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2008.tde-18122008-103054
Document
Auteur
Nom complet
Heinar Augusto Weiderpass
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2008
Directeur
Jury
Burattini, Marcelo Nascimento (Président)
Furuie, Sergio Shiguemi
Itiki, Cinthia
Massad, Eduardo
Sameshima, Koichi
Titre en portugais
Tratamento e análise de sinais neurológicos visuais com wavelets
Mots-clés en portugais
Acuidade visual
Córtex visual
P300
Potencial evocado
Resumé en portugais
O potencial visual evocado (PVE) é um sinal elétrico de baixa intensidade originado no córtex visual em resposta a uma estimulação visual periódica. O potencial visual evocado de varredura é um procedimento de PVE modificado para medir acuidade visual de grades em pacientes pré-verbais e não-verbais. Este biopotencial está imerso em uma grande quantidade de ruído eletroencefalográfico e artefato relacionado ao movimento. A relação sinal-ruído tem um papel dominante na determinação de erros sistemáticos e estatísticos. O propósito deste estudo é apresentar um método baseado na transformada wavelet para filtrar e extrair o potencial evocado visual de varredura. Grades de luminância de onda senoidal moduladas em 6 Hertz foram usadas como estímulo para se determinar os limiares de acuidade. A amplitude e a fase da 2ª. harmônica (12 Hertz) do padrão de resposta foram analisadas usando-se a transformada rápida de Fourier após a filtragem por wavelet. O método da transformada wavelet discreta foi usado para decompor o PVE em coeficientes wavelet, determinando-se quais destes representavam uma atividade significativa. Em um passo seguinte somente os coeficientes relevantes foram considerados, zerando-se os demais e reconstruindo-se, assim, o sinal PVE. Isto resultou na filtragem das demais freqüências que foram consideradas ruído. Simulações numéricas e análises com dados de PVE humanos mostraram que este método forneceu maior relação sinal-ruído quando comparado com o método clássico dos mínimos quadrados recursivo (RLS) e ainda uma análise de fase mais apropriada
Titre en anglais
Treatment and analysis of visual neurological signals with wavelets
Mots-clés en anglais
Event-related potentials P300
Visual acuity
Visual cortex
Resumé en anglais
Visually evoked potential (VEP) is a very small electrical signal originated in the visual cortex in response to periodic visual stimulation. Sweep-VEP is a modified VEP procedure used to measure grating visual acuity in non-verbal and preverbal patients. This biopotential is buried in a large amount of electroencephalographic noise and movement related artifact. The signal-to-noise ratio (SNR) plays a dominant role in determining both systematic and statistic errors. The purpose of this study is to present a method based on wavelet transform technique for filtering and extracting steady-state sweep-VEP. Counter-phase sine-wave luminance gratings modulated at 6 Hertz were used as stimuli to determine sweep-VEP grating acuity thresholds. The amplitude and phase of the second-harmonic (12 Hertz) pattern reversal response were analyzed using the fast Fourier transform after the wavelet filtering. The wavelet transform method was used to decompose the VEP signal into wavelet coefficients by a discrete wavelet analysis to determine which coefficients yield significant activity at the corresponding frequency. In a subsequent step only significant coefficients were considered and the remaining was set to zero allowing a reconstruction of the VEP signal. This procedure resulted in filtering out other frequencies that were considered noise. Numerical simulations and analyses of human VEP data showed that this method has provided higher SNR when compared with the classical recursive least squares (RLS) method. An additional advantage was a more appropriate phase analysis showing more realistic second-harmonic amplitude value during phase brake
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
heinaraweiderpass.pdf (4.52 Mbytes)
Date de Publication
2009-01-19
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.