• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2010.tde-03092010-140640
Document
Auteur
Nom complet
Eleni Stark Rodrigues
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2010
Directeur
Jury
Umbuzeiro, Gisela de Aragão (Président)
Kummrow, Fábio
Mauad, Thais
Nieto, Regis
Pereira, Luiz Alberto Amador
Titre en portugais
Gestão ambiental nos terminais de armazenagem de produtos químicos líquidos a granel no Porto de Santos
Mots-clés en portugais
Biodegradabilidade
Gestão ambiental
Ozonização
Reúso
Terminal químico
Testes de toxicidade
Vibrio fischeri
Resumé en portugais
O controle das águas residuárias nas indústrias e nos terminais de armazenagem de produtos químicos líquidos a granel é uma difícil tarefa, por conta da alta rotatividade e grande variedade de produtos químicos orgânicos armazenados e movimentados em suas atividades. Oito terminais e duas indústrias químicas localizadas no Porto de Santos foram avaliados por 10 anos. Foram realizadas mais de 2.500 análises químicas e ecotoxicológicas em 200 amostras de efluentes brutos e tratados. Nosso principal objetivo foi verificar se o teste de toxicidade aguda usando Vibrio fischeri poderia ser utilizado na gestão de águas residuais nas diferentes instalações dos terminais químicos e mostrar o seu papel como instrumento de prevenção a poluição, reduzindo a descarga de substâncias tóxicas persistentes nos ambientes aquáticos. Os índices de biodegradabilidade obtidos pela relação de Demanda Bioquímica de Oxigênio (DBO5) / Demanda Química de Oxigênio (DQO) dos efluentes brutos indicaram que 44% das amostras apresentaram matéria orgânica recalcitrante. Das 86 amostras do efluente final analisadas, 45 (52%) apresentaram resultados tóxicos para o teste com V. fischeri. Não houve correlação de DQO e ecotoxicidade, mostrando que efluentes com DQO baixa podem conter substâncias tóxicas com baixa capacidade de degradação. Foi possível recomendar a aplicação das melhores práticas operacionais, incluindo a segregação dos efluentes brutos ou um pré-tratamento com base nos resultados de ecotoxicidade e índice de biodegradabilidade. O reúso de água também foi abordado, indicando fontes e oportunidades de reutilização. Testes de ozonização também foram conduzidos nas águas pluviais dos terminais químicos e nos efluentes tratados das indústrias com resultados promissores. A integração da análise química e ecotoxicológica se mostraram uma excelente ferramenta para gestão de águas residuais nos terminais químicos, permitindo a tomada de decisão rápida para o controle da poluição e a adoção de medidas de prevenção
Titre en anglais
Environmental management of storage terminals of liquid chemicals in bulk at Santos Port
Mots-clés en anglais
Biodegradability
Chemical terminal
Environmental management
Ozonisation
Reuse
Toxicity tests
Vibrio fischeri
Resumé en anglais
Wastewater control at industries and storage terminals of liquid chemical products in bulk is very difficult task due to the high turnover and great variety of organic chemicals handled and stored in their activities. Eight terminals and two chemical plants located in Santos Port, SP, Brazil had been evaluated for 10 years. More than 2,500 chemical and ecotoxicological analysis were performed in 200 samples of raw and treated effluents. Our main objective was to verify if the acute toxicity test using Vibrio fischeri could be used in the wastewater management of those facilities and show its role as a tool for pollution prevention by reducing the discharge of persistent toxic substances in estuarine systems. The indexes of biodegradability obtained by the ratio of Biochemical Oxygen Demand (BOD5) / Chemical Oxygen Demand (COD) of raw effluents indicated that 44% of the samples presented recalcitrant organic matter. Out of 86 final effluent samples analyzed, 45 (52%) presented toxic result for V. fischeri test. No correlation was observed of COD and ecotoxicity, showing that with low COD effluent may contain toxic substances with low degradation capacity. It was possible to recommend the use of best operational practices including segregation of influents or a pre-treatment based on toxicity results and index biodegradability. Water reuse was also discussed indicating sources and opportunities for reuse in these facilities. Ozonisation tests were also conducted on the rain waters collected at the terminals facilities and on the treated effluents of the industries, showing promising results. The integration of chemical and ecotoxicity analysis turned out to be an excellent tool for wastewater management in chemical terminals, allowing rapid decision making for pollution control and prevention measures
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2010-09-08
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.