Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2013.tde-10052013-105804
Documento
Autor
Nombre completo
Henrique Faria Ramos
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2013
Director
Tribunal
Brito Neto, Rubens Vuono de (Presidente)
Fávero, Mariana Lopes
Francesco, Renata Cantisani di
Hueb, Marcelo Miguel
Portinho, Fernando Sérgio de Melo
Título en portugués
Avaliação da audição residual em candidatos  a implantes coclear atráves da resposta  auditiva de estado estável
Palabras clave en portugués
Implantes cocleares
Limiar auditivo
Perda auditiva neurossensorial
Potenciais evocados auditivos
Técnicas de diagnóstico em otologia
Resumen en portugués
INTRODUÇÃO: A identificação e preservação da audição residual em candidatos a implante coclear vêm assumindo maior importância clínica. A resposta auditiva de estado estável (RAEE) pode fornecer informação frequência-específica sobre o limiar auditivo em níveis de intensidade máximos de 120 dB NA, possibilitando a investigação da audição residual. Os objetivos deste estudo são avaliar a audição residual em candidatos a implante coclear, comparando os limiares eletrofisiológicos da RAEE com os limiares psicoacústicos da audiometria nas frequências de 500, 1 000, 2 000 e 4 000 Hz. MÉTODO: Foram avaliados 40 candidatos a implante coclear (80 orelhas) com perda auditiva neurossensorial severa a profunda bilateral. A audiometria foi realizada com o tom "warble" nas frequências de 500, 1 000, 2 000 e 4 000 Hz com intensidade máxima de estimulação de 120 dB NA. A RAEE foi obtida através da estimulação dicótica de uma frequência de tons contínuos sinusoidais modulados 100% em amplitude exponencial e 20% em frequência, nas frequências portadoras de 500, 1 000, 2 000 e 4 000 Hz, com estimulação máxima de 117, 120, 119 e 118 dB NA, respectivamente. RESULTADOS: Foram obtidos limiares mensuráveis em 62,5% de todas as frequências estudadas na audiometria tonal e em 63,1% na RAEE. A RAEE apresentou sensibilidade de 96% e especificidade de 91,6% na detecção da audição residual. As diferenças médias entre os limiares da audiometria tonal e da RAEE não apresentaram significância estatística em nenhuma das frequências. As correlações entre os limiares comportamentais e da RAEE foram significantes em todas as frequências avaliadas, sendo fortes em 500, 1 000 e 2 000 Hz e moderada em 4 000 Hz, com coeficiente de correlação de Pearson entre 0,65 e 0,81. Em 90% dos casos, os limiares da RAEE foram adquiridos nos limites de 10 dB dos limiares comportamentais. CONCLUSÕES: As correlações entre os limiares tonais e da RAEE foram significantes nas frequências de 500, 1 000, 2 000 e 4 000 Hz. A RAEE apresentou alta sensibilidade e especificidade na detecção da audição residual em candidatos a implante coclear, em comparação com a audiometria tonal
Título en inglés
Evaluation of residual hearing in cochlear implants candidates using auditory steady-state response
Palabras clave en inglés
Auditory evoked potentials
Auditory thresholds
Cochlear implants
Otological diagnostic techniques
Sensorineural hearing loss
Resumen en inglés
INTRODUCTION: Identification and preservation of residual hearing in cochlear implantation are becoming more important lately. Auditory steadystate response (ASSR) can provide frequency-specific information regarding the auditory thresholds at maximum intensity levels of 120 dB HL, allowing investigation of residual hearing. The study objectives are to assess residual hearing in cochlear implant candidates by comparing the electrophysiological thresholds obtained in ASSR with psychoacoustic thresholds of audiometry at 500, 1 000, 2 000 and 4 000 Hz. METHOD: Forty cochlear implant candidates (80 ears) with bilateral severe-to-profound sensorineural hearing loss were studied. Warble-tone audiometry was performed at the frequencies 500, 1 000, 2 000 e 4 000 Hz, with stimuli up to 120 dB HL. ASSR was obtained with dichotic single-frequency stimulation of sinusoidal continuous tones modulated in exponential amplitude of 100% and in frequency of 20%, at the carrier frequencies of 500, 1 000, 2 000 and 4 000 Hz at maximum stimulation levels of 117, 120, 119 and 118 dB HL, respectively. RESULTS: Thresholds were obtained in 62,5% of all frequencies evaluated in warbletone audiometry and in 63,1% in the ASSR. ASSR showed sensitivity of 96% and specificity of 91,6% in the detection of residual hearing. The mean difference between the thresholds of behavioral audiometry and ASSR were not statistically significant in any of the frequencies. Strong correlations between behavioral and ASSR thresholds were observed in 500, 1 000 and 2 000 Hz and moderate in 4 000 Hz, with Pearson correlation coefficient between 0,65 and 0,81. In 90% of the occasions, ASSR thresholds were within 10 dB of behavioral thresholds. CONCLUSIONS: The correlations between behavioral and ASSR thresholds were significant at 500, 1 000, 2 000 and 4 000 Hz. ASSR showed high sensitivity and specificity in the detection of residual hearing in cochlear implant candidates, compared to warble-tone audiometry
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2013-05-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.