• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.5.2010.tde-08062010-152653
Document
Author
Full name
Karisa Cristina Rodrigues Belotto
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2010
Supervisor
Committee
Gattaz, Wagner Farid (President)
Porta, Valentina
Sallet, Paulo Clemente
Title in Portuguese
Comparação da bioequivalência de duas formulações da risperidona
Keywords in Portuguese
Cromatografia líquida de alta pressão
Equivalência terapêutica
Farmacocinética
Risperidona
Abstract in Portuguese
Desde 1964, o Brasil tem lançado programas de políticas públicas para melhorar o acesso da população aos medicamentos considerados essenciais. Em 1999, com a criação da Agência Nacional de Vigilância Sanitária e a introdução dos medicamentos genéricos no mercado brasileiro, o Brasil passou a ter três classes de medicamentos disponíveis no mercado farmacêutico: referência, similar e genérico. O objetivo deste estudo foi avaliar a bioequivalência e intercambialidade entre dois antipsicóticos (referência e similar) utilizados pelo Instituto de Psiquiatria do Hospital das Clínicas da Universidade de São Paulo, contendo 2 mg de risperidona. Foi desenvolvido e validado um método analítico que emprega a cromatografia líquida de alta eficiência acoplada à espectrometria de massas para a determinação da risperidona (RSP) e seu principal metabólito a 9-hidroxirisperidona (9OH-RSP) em plasma. Para se avaliar a bioequivalência entre os medicamentos foram recrutados 22 voluntários sadios, os quais participaram do estudo clínico conduzido de forma cruzada e aleatória. As coletas sanguíneas para o ensaio de bioequivalência foram realizadas em tubos heparinizados (5 mL) e os tempos de coleta foram 0 (antes da medicação); 0,25; 0,5; 1; 1,5; 3; 5; 8; 12; 24; 48; 72; 96 e 120 horas após a administração da medicação. A determinação da bioequivalência entre os dois medicamentos deu-se através da comparação dos parâmetros farmacocinéticos: concentração plasmática máxima (Cmax), tempo para atingir a concentração plasmática máxima (Tmax) e área sobre a curva de decaimento plasmático (ASCT). Os resultados obtidos foram submetidos à análise de variância (ANOVA) e foi adotado o intervalo de confiança de 90% (IC 90%). Os valores médios para Cmax, Tmax e ASCT para RSP para os medicamentos referência e teste foram 16,02 ng/mL; 1,5 h e 348,94 ng.h/mL e 12,65 ng/mL; 1,5 h e 286,03 ng.h/mL, respectivamente. Já os valores médios para Cmax, Tmax e ASCT para 9OH-RSP para os medicamentos referência e teste foram 21,00 ng/mL; 5,0 h e 821,40 ng.h/mL e 17,85 ng/mL; 5,0 h e 632,92 ng.h/mL. Os valores de IC 90% para Cmax e ASCT para RSP para os medicamentos referência e teste foram 74 a 82% e 76 a 85%, respectivamente, e os valores de IC 90% para os mesmos parâmetros para 9OH-RSP foram 83 a 87% e 75 a 78%, respectivamente. Os resultados demonstraram diferenças significativas entre os medicamentos testados, o que permite concluir que os mesmos não são bioequivalentes e, portanto, não podem ser intercambiáveis
Title in English
Comparison of bioequivalence between two formulations of risperidone
Keywords in English
High pressure liquid chromatography
Pharmacokinetic
Risperidone
Therapeutic equivalency
Abstract in English
Brazil has launched programmes of public policies aiming to improve essential medicines access for the population since 1964. It was created in 1999 the National Agency for Sanitary Vigilance, which introduced the generic medicines in the Brazilian market, which already had the reference and the pharmaceutical equivalent ones. The objective of this study was to evaluate the bioequivalence and interchangeability between two antipsychotics (reference and pharmaceutical equivalent) used by the Institute of Psychiatry, Hospital of the Universidade de São Paulo, containing 2 mg of risperidone. It was developed and validated a high-performance liquid chromatography coupled to mass spectrometry method for the determination in plasma of risperidone (RSP) and its main metabolite, 9- hydroxy-risperidone (9OH-RSP). To assess bioequivalence between the medicines it was recruited 22 healthy volunteers, which took part in a clinical cross and random studies. The blood collections were performed on heparinizades tubes (5 ml) and runtimes collections were 0 (before medication); 0.25; 0.5; 1; 1.5; 3; 5; 8; 12; 24; 48; 72; 96 and 120 hours after the administration of medication. The determination of bioequivalence between the two drugs was achieved by a comparison of the following pharmacokinetic parameters: plasma concentration (Cmax), time to achieve Cmax (Tmax), and area under the plasma concentration-time curve (AUCT). Results were subjected to analysis of variance (ANOVA), adopting a confidence interval CI 90%. The average values for Cmax, Tmax and AUCT for RSP were 16.02 ng/ml, 1.5 h and 348.94 ng.h/ml for reference medicines and 12.65 ng/ml, 1.5 h and 286.03 ng.h/ml for testing ones. The average values for Cmax, Tmax and AUCT for 9OH-RSP were 21.00 ng/ml, 5.0 h and 821.40 ng.h/ml for reference medicines and 17.85 ng/ml, 5.0 h and 632.92 ng.h/ml for testing ones. CI 90% for Cmax and AUC (RSP) were 74-82% and 76-85%, respectively. The CI 90% for the same parameters for 9OH-RSP was 83-87% for reference medicines and 75-78% for testing ones. There was significant difference between the products tested, thus one can conclude they are not bioequivalents, therefore cannot be interchanged
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2010-06-08
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.