• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2008.tde-18122008-122329
Documento
Autor
Nombre completo
Erika Arai Furusawa
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2008
Director
Tribunal
Koch, Vera Hermina Kalika (Presidente)
Belangero, Vera Maria Santoro
Carvalhaes, João Tomas Abreu
Ramos, Sonia Regina Testa da Silva
Troster, Eduardo Juan
Título en portugués
Comparação das medidas de pressão arterial no consultório, no domicílio e pela monitorização ambulatorial da pressão arterial (MAPA) em crianças com hipertensão arterial
Palabras clave en portugués
Adolescente
Criança
Hipertensão
Monitorização ambulatorial da pressão arterial
Pressão arterial
Resumen en portugués
O diagnóstico e acompanhamento da hipertensão arterial (HA) no paciente pediátrico dependem da acurácia e da representatividade da medida da pressão arterial (PA). A monitorização ambulatorial da pressão arterial (MAPA), apesar de suas vantagens em relação à medida casual, apresenta custo elevado e pode trazer desconforto ao paciente. A medida residencial da pressão arterial (MRPA), apesar de pouco estudada na criança, apresenta-se como um alternativo potencial à MAPA. Os objetivos deste estudo foram comparar as medidas da PA aferidas no consultório, na MRPA, na Liga de Hipertensão e pela MAPA avaliando o efeito do ambiente/observador e determinando a freqüência de valores compatíveis com HA nessas 4 situações. Este estudo foi transversal,prospectivo e foram incluídos pacientes com HA e PA controlada ou não no consultório. Foram analisadas as médias das pressões arteriais sistólicas e diastólicas. A MRPA foi realizada com aparelho OMRON HEM 705 CP por 14 dias, em dois períodos (manhã ou tarde e noite). Na véspera do início da MRPA, o paciente compareceu à Liga de Hipertensão do HC-FMUSP para colocação do equipamento da MAPA (SPACELABS 90207). Foram analisados os dados de 40 pacientes (14 meninas e 26 meninos), idade média 12,1±3,6 anos. Não houve diferença estatística entre as médias das pressões sistólicas (ANOVA p=0,3100) e diastólicas (ANOVA p=0,7700) no consultório com as médias diurnas da MRPA e nem com as médias sistólicas (ANOVA p=0,8240) e diastólicas(ANOVA p=0,1530) do período noturno da MRPA. As médias das pressões sistólicas e diastólicas da Liga e da MAPA foram maiores do que as médias do consultório e da MRPA (p<0,001), porém não houve diferença estatística entre as médias sistólicas e diastólicas da Liga com a MAPA (p=0,077) e (p=0,962) respectivamente. As médias das pressões diastólicas da MRPA foram menores do que as médias do consultório (p=0,001). Em relação à freqüência de pacientes com PA não controlada, esta foi maior na Liga de Hipertensão (Mc Nemar p<0,005), enquanto as comparações entre consultório MRPA diurna, consultório-MAPA vigília, MRPA diurna- MAPA vigília não foram significantes (Mc Nemar p>0,05). Na MAPA sono, os pacientes apresentaram maior freqüência de PA controlada do que na MRPA noturna. Dez pacientes apresentaram PA não controlada no consultório, a MAPA confirmou o diagnóstico em 7/10 (17,5%) pacientes, enquanto 5/10 (12,5%) confirmaram pela MRPA. Nesse grupo, a hipertensão do avental branco ocorreu em 3/10 (7,5%) pacientes diagnosticados pela MAPA e em 5/10 (12,5%) diagnosticados pela MRPA.Trinta pacientes apresentaram valores de PA controlados no consultório, destes 24/30 (60%) pacientes confirmaram o diagnóstico pela MAPA e 26/30 (65%) pela MRPA. A hipertensão mascarada ocorreu em 6/30 (15%) pacientes diagnosticados pela MAPA e em 4/30 (10%) diagnosticados pela MRPA. Nesse estudo demonstrou-se concordância entre MAPA e MRPA (teste de Mc Nemar p<0,01) com boa reprodutibilidade à avaliação do índice Kappa (0,557).
Título en inglés
Comparison of blood pressure measurement in the office, at home and ambulatory blood pressure (ABP) in children with arterial hypertension
Palabras clave en inglés
Adolescent
Blood pressure
Blood pressure monitoring ambulatory
Child
Hypertension
Resumen en inglés
The diagnosis and monitoring of hypertension in pediatric patients depend on the accuracy and reproducibility of blood pressure (BP) measurement. Ambulatory blood pressure monitoring (ABPM), despite its advantages over office BP, is costly and can cause discomfort to the patient. The blood pressure measured at home (HBP), although poorly studied in children, represents a potential alternative to ABPM. The objectives of this study were to compare BP measurement in four clinical conditions: office BP , casual BP measured at Liga de Hipertensão, HBP and ABPM, evaluate the effect of environment / observer and to determine the frequency of BP values compatible with the diagnosis of hypertension. This study was cross-sectional and prospective and included patients with arterial hypertension with/without properly controlled BP in the office. The means of systolic and diastolic BP were analyzed in the 4 clinical conditions. HBP was measured for 14 days using a validated fully automatic Omron HEM 705 CP device. ABPM was measured with SpaceLabs 90207 non-invasive portable oscilometric device. We analyzed data from 40 patients (14 girls and 26 boys), mean age 12.1 ± 3.6 (SD) years. There was no difference between systolic (ANOVA p = 0.3100) and diastolic (ANOVA p= 0.7700) BP in the office and daytime HBP nor with nightime systolic HBP ( ANOVA p = 0.8240) and diastolic HBP(ANOVA p = 0.1530). The average systolic and diastolic BP at the Liga de Hipertensão and ABPM were higher than office and HB P (p <0001), but there was no difference in the average systolic (p= 0.077) and diastolic (p = 0.962) BP between Liga and ABPM. The diastolic HBP was lower than office diastolic BP (p = 0001). The frequency of BP values compatible with hipertension was higher at the Liga de Hipertensão (Mc Nemar p <0005), while comparisons between officedaytime HBP, office- daytime ABPM and daytime HBP-ABPM were not significant (Mc Nemar p> 0.05). The BP measurements during nightime ABPM showed a higher frequency of values compatible with hypertension than the night HBP one. Ten patients were diagnosed hypertension in the office, ABPM confirmed the diagnosis in 7 / 10 (17.5%) patients, while 5 / 10 (12.5%) were confirmed by HBP. In this group, white-coat hypertension occurred in 3 / 10 (7.5%) patients as diagnosed by the ABPM and 5 / 10 (12.5%) as diagnosed by HBP.Thirty patients presented BP values within normal limits in the office, 24 / 30 (60%) patients confirmed this diagnosis by ABPM and 26/30 (65%) by HBP. Masked hypertension was diagnosed in 6 / 30 (15%) patients diagnosed by the ABPM and in 4 / 30 (10%) by HBP. This study confirmed a correlation between ABPM and HBP measurements (Mc Nemar test p <0.01) with good reproducibility as evaluated by the Kappa index (0.557).
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
EricaAraiFurusawa.pdf (246.38 Kbytes)
Fecha de Publicación
2008-12-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.