Full name
Alexandre de Christo Viegas
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2003
Supervisor
Committee
Camanho, Gilberto Luis (President)
Carvalho Junior, Antonio Egydio de
Faloppa, Flavio
Title in Portuguese
"Análise das propriedades biomecânicas dos tendões dos músculos tibial anterior e tibial posterior : estudo experimental em cadáveres humanos"
Keywords in Portuguese
Artroscopia/métodos
Biomecânica
Ligamento cruzado anterior/cirurgia
Ligamento patelar/cirurgia
Músculo esquelético/fisiologia
Tíbia/fisiologia
Abstract in Portuguese
O autor estudou as propriedades biomecânicas dos tendões dos músculos tibial anterior e tibial posterior congelados a -20°C e a -86°C extraídos de cadáveres humanos frescos. Foram realizados ensaios mecânicos de tração até a ruptura e determinadas as seguintes propriedades: resistência máxima, coeficiente de rigidez, módulo de elasticidade e alongamento máximo relativo. Os dados obtidos foram comparados aos existentes na literatura relativos ao ligamento cruzado anterior, ligamento da patela e aos tendões dos músculos grácil e semitendíneo
Title in English
Biomechanical analysis of anterior and posterior tibialis tendons : experimental study in human cadavers
Keywords in English
Anterior cruciate ligament/surgery
Arthroscopy/methods
Biomechanics
Muscle Skeletal/physiology
Patellar ligament/surgery
Tibia/physiology
Abstract in English
The author studied the mechanical properties of the anterior and posterior tibialis muscle tendons frozen at -20°C and -86°C obtained from fresh-frozen human cadavers. The tendons were submitted to axial traction until failure and the following properties were determined: ultimate load, stiffness, modulus of elasticity and relative strain. Data obtained were compared to those from the literature related to the anterior cruciate ligament, patellar tendon, gracilis and semitendinous tendons
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2006-04-12
 
WARNING: Learn what derived works are clicking here.